Miniscrew-assisted rapid palatal expansion (MARPE): Factors influencing planning.

Q2 Medicine
Dental Press Journal of Orthodontics Pub Date : 2024-08-12 eCollection Date: 2024-01-01 DOI:10.1590/2177-6709.29.3.e242439.oar
Cristiane Barros André, Bruno de Paula Machado Pasqua, Gustavo de Andrade Jacquier, Fabio Dupart Nascimento
{"title":"Miniscrew-assisted rapid palatal expansion (MARPE): Factors influencing planning.","authors":"Cristiane Barros André, Bruno de Paula Machado Pasqua, Gustavo de Andrade Jacquier, Fabio Dupart Nascimento","doi":"10.1590/2177-6709.29.3.e242439.oar","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This cross-sectional study evaluated the bone thickness on mini-implants insertion site, the factors that influence the digital planning of MARPE appliance (miniscrew-assisted rapid palatal expansion), and its different designs.</p><p><strong>Methods: </strong>A total of 135 plannings were assessed regarding the size of the expander screw used, the positioning and the type of the mini-implant rings, and their location in relation to the teeth. Bone thickness measurements were assessed in the region of the mini-implants' trajectory. Differences between the sexes was verified using the ANOVA test (5% significance).</p><p><strong>Results: </strong>73 cases were planned with 4 mini-implants and 62 cases, with 6 mini-implants. In 90% of cases, teeth #16 and #26 were used as supports, and the most used expander screw was 13mm (64.1% of cases). The anterior mini-implants of conventional MARPE showed more pronounced insertion in bone in males (5.9 ± 2mm; p= 0.025). The extra mini-implants (anterior region) were inserted with greater bone thickness in males (11.1 ± 2.3mm) compared to females (9.9 ± 1.8mm; p=0.041). A greater bone thickness was observed in males (10.1 ± 2.1 mm) when using mini-implants in the paramedian region.</p><p><strong>Conclusion: </strong>Additional rings allow more pronounced bone insertion. Male patients had greater bone thickness, which may be related to greater difficulty in opening the sutures. The alveolar process region seems to be a satisfactory site for mini-implants to those patients with reduced bone thickness in the paramedian posterior region. MARPE appliance must be customized for each patient, due to bone thickness and anatomical variations.</p>","PeriodicalId":38720,"journal":{"name":"Dental Press Journal of Orthodontics","volume":"29 3","pages":"e242439"},"PeriodicalIF":0.0000,"publicationDate":"2024-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11321490/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Press Journal of Orthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/2177-6709.29.3.e242439.oar","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: This cross-sectional study evaluated the bone thickness on mini-implants insertion site, the factors that influence the digital planning of MARPE appliance (miniscrew-assisted rapid palatal expansion), and its different designs.

Methods: A total of 135 plannings were assessed regarding the size of the expander screw used, the positioning and the type of the mini-implant rings, and their location in relation to the teeth. Bone thickness measurements were assessed in the region of the mini-implants' trajectory. Differences between the sexes was verified using the ANOVA test (5% significance).

Results: 73 cases were planned with 4 mini-implants and 62 cases, with 6 mini-implants. In 90% of cases, teeth #16 and #26 were used as supports, and the most used expander screw was 13mm (64.1% of cases). The anterior mini-implants of conventional MARPE showed more pronounced insertion in bone in males (5.9 ± 2mm; p= 0.025). The extra mini-implants (anterior region) were inserted with greater bone thickness in males (11.1 ± 2.3mm) compared to females (9.9 ± 1.8mm; p=0.041). A greater bone thickness was observed in males (10.1 ± 2.1 mm) when using mini-implants in the paramedian region.

Conclusion: Additional rings allow more pronounced bone insertion. Male patients had greater bone thickness, which may be related to greater difficulty in opening the sutures. The alveolar process region seems to be a satisfactory site for mini-implants to those patients with reduced bone thickness in the paramedian posterior region. MARPE appliance must be customized for each patient, due to bone thickness and anatomical variations.

微型螺钉辅助快速腭部扩张术(MARPE):影响计划的因素。
研究目的这项横断面研究评估了微型种植体插入部位的骨厚度、影响MARPE矫治器(微型螺钉辅助快速腭部扩张器)数字化规划的因素及其不同设计:方法:共对 135 份计划进行了评估,内容涉及所用扩张器螺钉的大小、微型种植环的位置和类型,以及它们与牙齿的相对位置。对微型种植体轨迹区域的骨厚度进行了评估。性别差异通过方差分析检验(5%显著性)进行验证:73个病例计划植入4颗微型种植体,62个病例计划植入6颗微型种植体。在90%的病例中,16号和26号牙被用作支撑,使用最多的扩张器螺钉是13毫米(64.1%的病例)。传统 MARPE 的前部微型种植体在男性患者中插入骨质的情况更为明显(5.9 ± 2 毫米;P= 0.025)。与女性(9.9 ± 1.8 毫米;P=0.041)相比,男性植入的额外微型植入体(前部区域)的骨厚度更大(11.1 ± 2.3 毫米)。在副中线区域使用微型种植体时,男性的骨厚度更大(10.1 ± 2.1 毫米):结论:附加环可使骨插入更明显。男性患者的骨厚度更大,这可能与打开缝线的难度更大有关。对于骨厚度较低的副中线后牙区患者来说,牙槽突区似乎是一个令人满意的微型种植体植入部位。由于骨厚度和解剖结构的差异,MARPE 装置必须为每位患者量身定制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Dental Press Journal of Orthodontics
Dental Press Journal of Orthodontics Dentistry-Orthodontics
CiteScore
2.00
自引率
0.00%
发文量
40
审稿时长
27 weeks
期刊介绍: The Dental Press Journal of Orthodontics publishes scientific research articles, significant reviews, clinical and technical case reports, brief communications, and other materials related to Orthodontics and Facial Orthopedics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信