{"title":"A hybrid chaotic bat algorithm for optimal placement and sizing of dg units in radial distribution networks","authors":"","doi":"10.1016/j.egyr.2024.07.042","DOIUrl":null,"url":null,"abstract":"<div><p>Appropriate location and sizing of distributed generation (DG) units in a radial distribution system (RDS) play a significant role in the improvement of its overall performance. Indeed, proper DG placement and sizing help in maintaining the balance between power supply and demand, decreasing energy losses and enhancing voltage profile. Within this context, this paper presents an effective approach for the determination of the optimal location and the appropriate capacity of a photovoltaic distributed generation (PVDG) unit in RDSs. In the suggested approach, the best position of the PVDG is selected using the loss sensitivity factor (LSF). Meanwhile, a new optimization technique incorporating chaos, bats’ self-adaptive compensation, and Doppler effect into the original bat algorithm (BA) is developed to find the optimal size of the PVDG unit. The optimal PVDG size is optimally determined in such a way that total active power losses of the RDS is reduced and voltage profile is enhanced. The performance of the proposed optimization technique, symbolized by (CSA-DC)BA, is evaluated using various benchmark functions. Moreover, the applicability and effectiveness of the suggested approach are verified on the IEEE 33-bus and the IEEE 69-bus RDSs. Obtained results revealed that the proposed (CSA-DC)BA outperforms the comparison optimization techniques.</p></div>","PeriodicalId":11798,"journal":{"name":"Energy Reports","volume":null,"pages":null},"PeriodicalIF":4.7000,"publicationDate":"2024-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2352484724004657/pdfft?md5=08c9c204ba01d30ad69c54a6827d781a&pid=1-s2.0-S2352484724004657-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Reports","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352484724004657","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0
Abstract
Appropriate location and sizing of distributed generation (DG) units in a radial distribution system (RDS) play a significant role in the improvement of its overall performance. Indeed, proper DG placement and sizing help in maintaining the balance between power supply and demand, decreasing energy losses and enhancing voltage profile. Within this context, this paper presents an effective approach for the determination of the optimal location and the appropriate capacity of a photovoltaic distributed generation (PVDG) unit in RDSs. In the suggested approach, the best position of the PVDG is selected using the loss sensitivity factor (LSF). Meanwhile, a new optimization technique incorporating chaos, bats’ self-adaptive compensation, and Doppler effect into the original bat algorithm (BA) is developed to find the optimal size of the PVDG unit. The optimal PVDG size is optimally determined in such a way that total active power losses of the RDS is reduced and voltage profile is enhanced. The performance of the proposed optimization technique, symbolized by (CSA-DC)BA, is evaluated using various benchmark functions. Moreover, the applicability and effectiveness of the suggested approach are verified on the IEEE 33-bus and the IEEE 69-bus RDSs. Obtained results revealed that the proposed (CSA-DC)BA outperforms the comparison optimization techniques.
期刊介绍:
Energy Reports is a new online multidisciplinary open access journal which focuses on publishing new research in the area of Energy with a rapid review and publication time. Energy Reports will be open to direct submissions and also to submissions from other Elsevier Energy journals, whose Editors have determined that Energy Reports would be a better fit.