{"title":"Wavelet Coherence Analysis of Post-Stroke Intermuscular Coupling Modulated by Myoelectric-Controlled Interfaces","authors":"Xinyi He, Wenbo Sun, Rong Song, Weiling Xu","doi":"10.3390/bioengineering11080802","DOIUrl":null,"url":null,"abstract":"Intermuscular coupling reflects the corticospinal interaction associated with the control of muscles. Nevertheless, the deterioration of intermuscular coupling caused by stroke has not received much attention. The purpose of this study was to investigate the effect of myoelectric-controlled interface (MCI) dimensionality on the intermuscular coupling after stroke. In total, ten age-matched controls and eight stroke patients were recruited and executed elbow tracking tasks within 1D or 2D MCI. Movement performance was quantified using the root mean square error (RMSE). Wavelet coherence was used to analyze the intermuscular coupling in alpha band (8–12 Hz) and beta band (15–35 Hz). The results found that smaller RMSE of antagonist muscles was observed in both groups within 2D MCI compared to 1D MCI. The alpha-band wavelet coherence was significantly lower in the patients compared to the controls during elbow extension. Furthermore, a decreased alpha-band and beta-band wavelet coherence was observed in the controls and stroke patients, as the dimensionality of MCI increased. These results may suggest that stroke-related neural impairments deteriorate the motor performance and intermuscular coordination pattern, and, further, that MCI holds promise as a novel effective tool for rehabilitation through the direct modulation of muscle activation pattern.","PeriodicalId":8874,"journal":{"name":"Bioengineering","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioengineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bioengineering11080802","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Intermuscular coupling reflects the corticospinal interaction associated with the control of muscles. Nevertheless, the deterioration of intermuscular coupling caused by stroke has not received much attention. The purpose of this study was to investigate the effect of myoelectric-controlled interface (MCI) dimensionality on the intermuscular coupling after stroke. In total, ten age-matched controls and eight stroke patients were recruited and executed elbow tracking tasks within 1D or 2D MCI. Movement performance was quantified using the root mean square error (RMSE). Wavelet coherence was used to analyze the intermuscular coupling in alpha band (8–12 Hz) and beta band (15–35 Hz). The results found that smaller RMSE of antagonist muscles was observed in both groups within 2D MCI compared to 1D MCI. The alpha-band wavelet coherence was significantly lower in the patients compared to the controls during elbow extension. Furthermore, a decreased alpha-band and beta-band wavelet coherence was observed in the controls and stroke patients, as the dimensionality of MCI increased. These results may suggest that stroke-related neural impairments deteriorate the motor performance and intermuscular coordination pattern, and, further, that MCI holds promise as a novel effective tool for rehabilitation through the direct modulation of muscle activation pattern.
期刊介绍:
Aims
Bioengineering (ISSN 2306-5354) provides an advanced forum for the science and technology of bioengineering. It publishes original research papers, comprehensive reviews, communications and case reports. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. All aspects of bioengineering are welcomed from theoretical concepts to education and applications. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. There are, in addition, four key features of this Journal:
● We are introducing a new concept in scientific and technical publications “The Translational Case Report in Bioengineering”. It is a descriptive explanatory analysis of a transformative or translational event. Understanding that the goal of bioengineering scholarship is to advance towards a transformative or clinical solution to an identified transformative/clinical need, the translational case report is used to explore causation in order to find underlying principles that may guide other similar transformative/translational undertakings.
● Manuscripts regarding research proposals and research ideas will be particularly welcomed.
● Electronic files and software regarding the full details of the calculation and experimental procedure, if unable to be published in a normal way, can be deposited as supplementary material.
● We also accept manuscripts communicating to a broader audience with regard to research projects financed with public funds.
Scope
● Bionics and biological cybernetics: implantology; bio–abio interfaces
● Bioelectronics: wearable electronics; implantable electronics; “more than Moore” electronics; bioelectronics devices
● Bioprocess and biosystems engineering and applications: bioprocess design; biocatalysis; bioseparation and bioreactors; bioinformatics; bioenergy; etc.
● Biomolecular, cellular and tissue engineering and applications: tissue engineering; chromosome engineering; embryo engineering; cellular, molecular and synthetic biology; metabolic engineering; bio-nanotechnology; micro/nano technologies; genetic engineering; transgenic technology
● Biomedical engineering and applications: biomechatronics; biomedical electronics; biomechanics; biomaterials; biomimetics; biomedical diagnostics; biomedical therapy; biomedical devices; sensors and circuits; biomedical imaging and medical information systems; implants and regenerative medicine; neurotechnology; clinical engineering; rehabilitation engineering
● Biochemical engineering and applications: metabolic pathway engineering; modeling and simulation
● Translational bioengineering