Stefanie Siegrist, Thomas Wyss, Athanasia Korda, Georgios Mantokoudis
{"title":"Clinical Assessment of the Nystagmus Fixation Suppression Test: An Experimental Study.","authors":"Stefanie Siegrist, Thomas Wyss, Athanasia Korda, Georgios Mantokoudis","doi":"10.5152/iao.2024.231249","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong> Assessment of nystagmus fixation suppression can be used as an additional diagnostic tool for patients with an acute vestibular syndrome to distinguish between a central or peripheral cause. We investigated the ability of physicians to detect fixation suppression using a nystagmus simulation model.</p><p><strong>Methods: </strong> We used a nystagmus simulator to measure the accuracy of the nystagmus fixation suppression test. Fixation suppression was assessed randomly in 6170 trials by 20 otorhinolaryngologists and neurologists, segregated into 2 groups based on their neurootological experience, a beginner and an experienced group. The simulator presented random nystagmus slow velocity (SPV) reductions and presented 3 conditions with either changed nystagmus frequency, amplitude, or both.</p><p><strong>Results: </strong> The cutoff for the discernment of fixation suppression ranged from 1.2 to 14°/s nystagmus velocity difference. The more intense the baseline nystagmus was, the more difficult was the detection of fixation suppression. There was not significant difference (P >.05) in the cutoff values in the experts group compared to the novices for all 3 different conditions. Both, novices and experts, detected frequency changes easier than differences of the nystagmus amplitude. Test sensitivity was very low (19%-65%) for discernment of small nystagmus velocity differences of <2°/s by experts.</p><p><strong>Conclusion: </strong> In our study, there was no difference between experts and novices in detection of nystagmus suppression by visual fixation. The examiners could only detect large suppression effects at low-intensity baseline nystagmus. Overall, the sensitivity and accuracy of a clinical fixation suppression test is low and the assistance with a video-oculography device is highly recommended.</p>","PeriodicalId":94238,"journal":{"name":"The journal of international advanced otology","volume":"20 3","pages":"241-246"},"PeriodicalIF":0.0000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11232042/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The journal of international advanced otology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5152/iao.2024.231249","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Assessment of nystagmus fixation suppression can be used as an additional diagnostic tool for patients with an acute vestibular syndrome to distinguish between a central or peripheral cause. We investigated the ability of physicians to detect fixation suppression using a nystagmus simulation model.
Methods: We used a nystagmus simulator to measure the accuracy of the nystagmus fixation suppression test. Fixation suppression was assessed randomly in 6170 trials by 20 otorhinolaryngologists and neurologists, segregated into 2 groups based on their neurootological experience, a beginner and an experienced group. The simulator presented random nystagmus slow velocity (SPV) reductions and presented 3 conditions with either changed nystagmus frequency, amplitude, or both.
Results: The cutoff for the discernment of fixation suppression ranged from 1.2 to 14°/s nystagmus velocity difference. The more intense the baseline nystagmus was, the more difficult was the detection of fixation suppression. There was not significant difference (P >.05) in the cutoff values in the experts group compared to the novices for all 3 different conditions. Both, novices and experts, detected frequency changes easier than differences of the nystagmus amplitude. Test sensitivity was very low (19%-65%) for discernment of small nystagmus velocity differences of <2°/s by experts.
Conclusion: In our study, there was no difference between experts and novices in detection of nystagmus suppression by visual fixation. The examiners could only detect large suppression effects at low-intensity baseline nystagmus. Overall, the sensitivity and accuracy of a clinical fixation suppression test is low and the assistance with a video-oculography device is highly recommended.