[Unattended automatic office blood pressure measurement: the new standard?]

Q4 Medicine
Mark C van der Wel
{"title":"[Unattended automatic office blood pressure measurement: the new standard?]","authors":"Mark C van der Wel","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Unattended automatic office blood pressure measurement (uAOBP) is starting to become recognised as the preferred method of blood pressure measurement in practice. The body of evidence to support this position is growing. uAOBP decreases intra- and interobserver variability by reducing measurement error. In addition it reduces the white coat effect. Currently three protocols are validated and used the most, with different countries and/or settings preferring different protocols: BpTRU protocol, SPRINT protocol and 30-minute OBP protocol. In this overview all three protocols are discussed extensively based on current available evidence including pro and con's, accuracy and prognostic value.</p>","PeriodicalId":18903,"journal":{"name":"Nederlands tijdschrift voor geneeskunde","volume":"168 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nederlands tijdschrift voor geneeskunde","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Unattended automatic office blood pressure measurement (uAOBP) is starting to become recognised as the preferred method of blood pressure measurement in practice. The body of evidence to support this position is growing. uAOBP decreases intra- and interobserver variability by reducing measurement error. In addition it reduces the white coat effect. Currently three protocols are validated and used the most, with different countries and/or settings preferring different protocols: BpTRU protocol, SPRINT protocol and 30-minute OBP protocol. In this overview all three protocols are discussed extensively based on current available evidence including pro and con's, accuracy and prognostic value.

[无人值守的办公室自动血压测量:新标准?]
无人值守办公室自动血压测量(uAOBP)已开始被公认为实际测量血压的首选方法。uAOBP 可减少测量误差,从而降低观察者内部和观察者之间的变异性。此外,它还能减少白大衣效应。目前有三种方案经过验证,使用最多,不同的国家和/或环境倾向于使用不同的方案:BpTRU方案、SPRINT方案和30分钟OBP方案。在本概述中,我们将根据当前可用的证据(包括正反两方面的证据、准确性和预后价值)对这三种方案进行广泛讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Nederlands tijdschrift voor geneeskunde
Nederlands tijdschrift voor geneeskunde Medicine-Medicine (all)
CiteScore
0.30
自引率
0.00%
发文量
302
期刊介绍: Het NTVG staat bekend als hét wetenschappelijke algemene medische tijdschrift. De lange historie en de degelijkheid maken het tijdschrift tot een bolwerk van medische wetenschap in druk. Ook door de goede leesbaarheid draagt het tijdschrift bij aan de voortdurende dialoog over de geneeskunde.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信