Guide catheter extension use in chronic total occlusion percutaneous coronary intervention: insights from the PROGRESS CTO registry.

IF 1.6 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Ahmed Al-Ogaili, Deniz Mutlu, Michaella Alexandrou, Athanasios Rempakos, Bavana V Rangan, Olga C Mastrodemos, Yader Sandoval, M Nicholas Burke, Emmanouil S Brilakis
{"title":"Guide catheter extension use in chronic total occlusion percutaneous coronary intervention: insights from the PROGRESS CTO registry.","authors":"Ahmed Al-Ogaili, Deniz Mutlu, Michaella Alexandrou, Athanasios Rempakos, Bavana V Rangan, Olga C Mastrodemos, Yader Sandoval, M Nicholas Burke, Emmanouil S Brilakis","doi":"10.25270/jic/24.00117","DOIUrl":null,"url":null,"abstract":"<p><p>There are limited data on the use of guide catheter extensions (GCE) during chronic total occlusion (CTO) percutaneous coronary intervention (PCI). We examined the frequency and temporal trends of GCE use in a large multicenter CTO-PCI registry and compared the clinical and angiographic characteristics and outcomes of cases with vs without GCE use. A GCE was used in 4106 of 14 521 CTO PCIs (28%) with increasing frequency from 18.8% in 2012 to 29.9% in 2023. The most used GCE size was 6 French (Fr) (45%), followed by 7 Fr (34%), and 8 Fr (21%). CTOs that required GCE use were more likely to have unfavorable lesion characteristics such as moderate-to-severe calcification (59% vs 40%, P < .0001), moderate-to-severe tortuosity (35% vs 28%, P < .0001), proximal cap ambiguity (39% vs 33%, P < .0001), and had higher J-CTO scores (2.78 ± 1.15 vs 2.20 ± 1.27, P < .0001). Advanced techniques like the retrograde approach (44% vs 24%, P < .0001) and antegrade dissection and re-entry (28% vs 17%, P < .0001) were more likely to be used in GCE cases. Technical success (86.6% vs 86.8%, P = .816) was similar between the 2 groups. However, major adverse cardiovascular events (MACE) (3.8% vs 2.4%, P < .0001) and procedural complications (11.2% vs 8.7%, P < .0001) were more frequent in the GCE group. In summary, GCE use in CTO PCI significantly increased between 2012 and 2023. Cases that required GCEs were more complex and had similar technical success, but higher incidence of MACE compared with cases that did not require GCEs.</p>","PeriodicalId":49261,"journal":{"name":"Journal of Invasive Cardiology","volume":" ","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2024-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Invasive Cardiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.25270/jic/24.00117","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

There are limited data on the use of guide catheter extensions (GCE) during chronic total occlusion (CTO) percutaneous coronary intervention (PCI). We examined the frequency and temporal trends of GCE use in a large multicenter CTO-PCI registry and compared the clinical and angiographic characteristics and outcomes of cases with vs without GCE use. A GCE was used in 4106 of 14 521 CTO PCIs (28%) with increasing frequency from 18.8% in 2012 to 29.9% in 2023. The most used GCE size was 6 French (Fr) (45%), followed by 7 Fr (34%), and 8 Fr (21%). CTOs that required GCE use were more likely to have unfavorable lesion characteristics such as moderate-to-severe calcification (59% vs 40%, P < .0001), moderate-to-severe tortuosity (35% vs 28%, P < .0001), proximal cap ambiguity (39% vs 33%, P < .0001), and had higher J-CTO scores (2.78 ± 1.15 vs 2.20 ± 1.27, P < .0001). Advanced techniques like the retrograde approach (44% vs 24%, P < .0001) and antegrade dissection and re-entry (28% vs 17%, P < .0001) were more likely to be used in GCE cases. Technical success (86.6% vs 86.8%, P = .816) was similar between the 2 groups. However, major adverse cardiovascular events (MACE) (3.8% vs 2.4%, P < .0001) and procedural complications (11.2% vs 8.7%, P < .0001) were more frequent in the GCE group. In summary, GCE use in CTO PCI significantly increased between 2012 and 2023. Cases that required GCEs were more complex and had similar technical success, but higher incidence of MACE compared with cases that did not require GCEs.

慢性全闭塞经皮冠状动脉介入治疗中导引导管延伸的使用:PROGRESS CTO 登记的启示。
关于在慢性全闭塞(CTO)经皮冠状动脉介入治疗(PCI)过程中使用导引导管延长器(GCE)的数据很有限。我们研究了大型多中心 CTO-PCI 登记中使用 GCE 的频率和时间趋势,并比较了使用和未使用 GCE 病例的临床和血管造影特征及预后。在 14 521 例 CTO PCI 中,有 4106 例(28%)使用了 GCE,使用频率从 2012 年的 18.8% 增加到 2023 年的 29.9%。使用最多的 GCE 尺寸是 6 Fr(45%),其次是 7 Fr(34%)和 8 Fr(21%)。需要使用 GCE 的 CTO 更有可能具有不利的病变特征,如中度至重度钙化(59% vs 40%,P < .0001)、中度至重度迂曲(35% vs 28%,P < .0001)、近端帽模糊(39% vs 33%,P < .0001),并且具有更高的 J-CTO 评分(2.78 ± 1.15 vs 2.20 ± 1.27,P < .0001)。逆行入路(44% vs 24%,P < .0001)和前向剥离和再入路(28% vs 17%,P < .0001)等先进技术更有可能用于GCE病例。两组的技术成功率(86.6% vs 86.8%,P = .816)相似。但是,GCE 组的主要不良心血管事件 (MACE) (3.8% vs 2.4%,P < .0001)和手术并发症(11.2% vs 8.7%,P < .0001)发生率更高。总之,2012 年至 2023 年期间,CTO PCI 中 GCE 的使用显著增加。与不需要 GCE 的病例相比,需要 GCE 的病例更复杂,技术成功率相似,但 MACE 发生率更高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Invasive Cardiology
Journal of Invasive Cardiology CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.90
自引率
6.70%
发文量
214
审稿时长
3-8 weeks
期刊介绍: The Journal of Invasive Cardiology will consider for publication suitable articles on topics pertaining to the invasive treatment of patients with cardiovascular disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信