Acute effects of local vibration inducing tonic vibration reflex or illusion of movement on maximal wrist force production.

IF 3.3 3区 医学 Q1 PHYSIOLOGY
Journal of applied physiology Pub Date : 2024-10-01 Epub Date: 2024-08-08 DOI:10.1152/japplphysiol.00192.2024
Nicolas Amiez, Pierre Géhin, Alain Martin, Christos Paizis
{"title":"Acute effects of local vibration inducing tonic vibration reflex or illusion of movement on maximal wrist force production.","authors":"Nicolas Amiez, Pierre Géhin, Alain Martin, Christos Paizis","doi":"10.1152/japplphysiol.00192.2024","DOIUrl":null,"url":null,"abstract":"<p><p>Local vibration (LV) mainly stimulates primary afferents (Ia) and can induce a tonic vibration reflex (TVR) and an illusion of movement. This study aimed to evaluate the effect of these two phenomena on maximal voluntary isometric contraction (MVIC) capacity. LV (80 Hz) was applied to the wrist flexor muscles in two randomized experiments for 6 min. LV conditions were adjusted to promote either TVR (visual focus on the vibrated wrist) or ILLUSION [hand hidden, visual focus on electromyographic activity of the flexor carpi radialis muscle (FCR)]. Mechanical and electromyographic (EMG) responses of the FCR and extensor carpi radialis muscles were recorded during MVIC in flexion and extension and during electrically evoked contractions at supramaximal intensity. Measurements were performed before (10 min and just before) and after (0 and 30 min) LV protocol. An increase in FCR EMG was observed during LV in the TVR condition (+340%) compared with the illusion condition (<i>P</i> = 0.003). In contrast, the movement illusion was greater in the ILLUSION condition (assessed through subjective scales) (<i>P</i> = 0.004). MVIC was reduced in flexion only after the TVR condition ([Formula: see text], all <i>P</i> < 0.034). Moreover, the decrease in force was correlated with the amount of TVR recorded on the FCR muscle (<i>r</i> = -0.64, <i>P</i> = 0.005). Although potentiated doublets of each muscle did not evolve differently between conditions, a decrease was observed between the first and the last measure. In conclusion, when conducting research to assess maximal strength, it is necessary to have better control and reporting of the phenomena induced during LV.<b>NEW & NOTEWORTHY</b> The maximal force production of the vibrated muscle is reduced after 6 min of LV only in TVR condition. Furthermore, the amount of TVR is negatively correlated with this force decrease. When measuring the effects of LV on maximal force production, it is important to control and report any phenomena induced during vibration, such as TVR or movement illusion, which can be achieved by recording EMG activity of vibrated muscle and quantifying illusion.</p>","PeriodicalId":15160,"journal":{"name":"Journal of applied physiology","volume":" ","pages":"800-813"},"PeriodicalIF":3.3000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of applied physiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1152/japplphysiol.00192.2024","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/8 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"PHYSIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Local vibration (LV) mainly stimulates primary afferents (Ia) and can induce a tonic vibration reflex (TVR) and an illusion of movement. This study aimed to evaluate the effect of these two phenomena on maximal voluntary isometric contraction (MVIC) capacity. LV (80 Hz) was applied to the wrist flexor muscles in two randomized experiments for 6 min. LV conditions were adjusted to promote either TVR (visual focus on the vibrated wrist) or ILLUSION [hand hidden, visual focus on electromyographic activity of the flexor carpi radialis muscle (FCR)]. Mechanical and electromyographic (EMG) responses of the FCR and extensor carpi radialis muscles were recorded during MVIC in flexion and extension and during electrically evoked contractions at supramaximal intensity. Measurements were performed before (10 min and just before) and after (0 and 30 min) LV protocol. An increase in FCR EMG was observed during LV in the TVR condition (+340%) compared with the illusion condition (P = 0.003). In contrast, the movement illusion was greater in the ILLUSION condition (assessed through subjective scales) (P = 0.004). MVIC was reduced in flexion only after the TVR condition ([Formula: see text], all P < 0.034). Moreover, the decrease in force was correlated with the amount of TVR recorded on the FCR muscle (r = -0.64, P = 0.005). Although potentiated doublets of each muscle did not evolve differently between conditions, a decrease was observed between the first and the last measure. In conclusion, when conducting research to assess maximal strength, it is necessary to have better control and reporting of the phenomena induced during LV.NEW & NOTEWORTHY The maximal force production of the vibrated muscle is reduced after 6 min of LV only in TVR condition. Furthermore, the amount of TVR is negatively correlated with this force decrease. When measuring the effects of LV on maximal force production, it is important to control and report any phenomena induced during vibration, such as TVR or movement illusion, which can be achieved by recording EMG activity of vibrated muscle and quantifying illusion.

局部振动诱发强直性振动反射或运动错觉对最大腕力产生的急性影响。
局部振动(LV)主要刺激初级传入神经(Ia),可诱发强直性振动反射(TVR)和运动错觉。本研究旨在评估这两种现象对最大自主等长收缩能力(MVIC)的影响。在两个随机实验中,对腕屈肌施加 LV(80 Hz)6 分钟。调整 LV 条件以促进 TVR(视觉聚焦于振动的手腕)或 ILLUSION(手隐藏,视觉聚焦于腕屈肌 (FCR) 的肌电活动)。在弯曲和伸展的 MVIC 过程中,以及在超大强度的电诱发收缩过程中,记录了桡侧屈肌和桡侧伸肌的机械和肌电图(EMG)反应。测量在 LV 方案之前(10 分钟和之前)和之后(0 分钟和 30 分钟)进行。与幻觉状态相比,TVR 状态(+340%)下 LV 期间的 FCR EMG 有所增加(P=0.003)。相比之下,幻觉状态下的运动幻觉更大(通过主观量表评估)(P=0.004)。只有在 TVR 条件下,屈曲时的 MVIC 才会降低(≈ -7%,Pr=-0.64,P=0.005)。虽然在不同条件下,每块肌肉的电位加倍没有不同的变化,但在第一次和最后一次测量之间观察到了下降。总之,在进行最大力量评估研究时,有必要更好地控制和报告 LV 期间诱发的现象。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.00
自引率
9.10%
发文量
296
审稿时长
2-4 weeks
期刊介绍: The Journal of Applied Physiology publishes the highest quality original research and reviews that examine novel adaptive and integrative physiological mechanisms in humans and animals that advance the field. The journal encourages the submission of manuscripts that examine the acute and adaptive responses of various organs, tissues, cells and/or molecular pathways to environmental, physiological and/or pathophysiological stressors. As an applied physiology journal, topics of interest are not limited to a particular organ system. The journal, therefore, considers a wide array of integrative and translational research topics examining the mechanisms involved in disease processes and mitigation strategies, as well as the promotion of health and well-being throughout the lifespan. Priority is given to manuscripts that provide mechanistic insight deemed to exert an impact on the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信