{"title":"Transcatheter Valve-in-Valve Replacement With Balloon- Versus Self-Expanding Valves in Patients With Degenerated Stentless Aortic Bioprosthesis","authors":"","doi":"10.1016/j.amjcard.2024.08.001","DOIUrl":null,"url":null,"abstract":"<div><p>Valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) has been associated with favorable outcomes in patients with degenerated stentless bioprosthesis. However, whether the outcomes after ViV TAVR for failed stentless bioprosthesis differ between balloon-expandable valves (BEVs) and self-expanding valves (SEVs) remains unknown. Therefore, we retrospectively analyzed 59 consecutive patients who underwent ViV TAVR for failed stentless bioprsothesis with BEVs (n = 42) versus SEVs (n = 17) in a single–health care system between 2013 and 2022. Overall, the mean age was 70.8 years and 74.6% were men. The mean transcatheter valve size was 26.3 ± 2.2 mm for BEVs and 26.4 ± 4 mm for SEVs (p = 0.93). The mean Society of Thoracic Surgeons score was 6.0 ± 3.6 for BEVs and 7.5 ± 5.5 for SEVs (p = 0.22). Compared with patients who received BEVs, those who received SEVs had higher rates of device malposition (2.4% vs 23.5%, p <0.01), postdeployment balloon dilation (11.9% vs 35.5%, p = 0.04) and need for a second transcatheter device (2.4% vs 35.5%, p <0.01). However, both groups showed similar improvement in aortic valve function at 30-day and 1-year follow-up (incidence of 1-year severe patient-prosthesis mismatch in BEVs: 17.6% vs 14.3% in SEVs, p = 0.78). The 1- and 3-year mortality did not differ between BEVs and SEVs (11.9% vs 11.8% and 25% vs 30%, respectively, Log rank p = 0.9). In conclusion, performing ViV TAVR for failed stentless bioprsothesis is technically challenging, especially when using SEVs; however, satisfactory positioning is possible in most cases, with excellent hemodynamic and clinical outcomes with BEVs and SEVs.</p></div>","PeriodicalId":7705,"journal":{"name":"American Journal of Cardiology","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-08-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Cardiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0002914924005770","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) has been associated with favorable outcomes in patients with degenerated stentless bioprosthesis. However, whether the outcomes after ViV TAVR for failed stentless bioprosthesis differ between balloon-expandable valves (BEVs) and self-expanding valves (SEVs) remains unknown. Therefore, we retrospectively analyzed 59 consecutive patients who underwent ViV TAVR for failed stentless bioprsothesis with BEVs (n = 42) versus SEVs (n = 17) in a single–health care system between 2013 and 2022. Overall, the mean age was 70.8 years and 74.6% were men. The mean transcatheter valve size was 26.3 ± 2.2 mm for BEVs and 26.4 ± 4 mm for SEVs (p = 0.93). The mean Society of Thoracic Surgeons score was 6.0 ± 3.6 for BEVs and 7.5 ± 5.5 for SEVs (p = 0.22). Compared with patients who received BEVs, those who received SEVs had higher rates of device malposition (2.4% vs 23.5%, p <0.01), postdeployment balloon dilation (11.9% vs 35.5%, p = 0.04) and need for a second transcatheter device (2.4% vs 35.5%, p <0.01). However, both groups showed similar improvement in aortic valve function at 30-day and 1-year follow-up (incidence of 1-year severe patient-prosthesis mismatch in BEVs: 17.6% vs 14.3% in SEVs, p = 0.78). The 1- and 3-year mortality did not differ between BEVs and SEVs (11.9% vs 11.8% and 25% vs 30%, respectively, Log rank p = 0.9). In conclusion, performing ViV TAVR for failed stentless bioprsothesis is technically challenging, especially when using SEVs; however, satisfactory positioning is possible in most cases, with excellent hemodynamic and clinical outcomes with BEVs and SEVs.
期刊介绍:
Published 24 times a year, The American Journal of Cardiology® is an independent journal designed for cardiovascular disease specialists and internists with a subspecialty in cardiology throughout the world. AJC is an independent, scientific, peer-reviewed journal of original articles that focus on the practical, clinical approach to the diagnosis and treatment of cardiovascular disease. AJC has one of the fastest acceptance to publication times in Cardiology. Features report on systemic hypertension, methodology, drugs, pacing, arrhythmia, preventive cardiology, congestive heart failure, valvular heart disease, congenital heart disease, and cardiomyopathy. Also included are editorials, readers'' comments, and symposia.