Nathália Moraes Carvalho Barreto Brandão, Raiane Machado Maia, Victor de Morais Gomes, Carolina Resende, Alberto Nogueira da Gama Antunes, Bernardo Quiroga Souki
{"title":"Bonding positional accuracy of attachments and marginal adaptation of in-house aligners – A quality improvement laboratory study","authors":"Nathália Moraes Carvalho Barreto Brandão, Raiane Machado Maia, Victor de Morais Gomes, Carolina Resende, Alberto Nogueira da Gama Antunes, Bernardo Quiroga Souki","doi":"10.1111/ocr.12843","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objectives</h3>\n \n <p>To evaluate the 3D accuracy of attachment positioning and the adaptation of aligners to attachments using in-house templates made with either polyethylene terephthalate glycol (PETG) or ethylene-vinyl acetate (EVA) and either pressure or vacuum thermoforming machines.</p>\n </section>\n \n <section>\n \n <h3> Materials and Methods</h3>\n \n <p>Overall, 140 test specimens were resin-printed. Templates for the attachment bonding were made with 1-mm EVA or 0.5-mm PETG laminates. Orthodontic aligners were manufactured with 0.75-mm PETG. The thermoplastification process was carried out using either vacuum or pressure machines. The positional differences between the virtual and bonded attachments were assessed in the <i>X</i>, <i>Y</i> and <i>Z</i> coordinates. The marginal adaptation between the aligners and the attachments was measured.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Minor inaccuracies in the positioning of the attachments were observed in all combinations of thermoforming machines and plastic laminates used to fabricate the templates, mainly in the superior–inferior (<i>Z</i>) dimension. PETG performed better than EVA in the anterior region (<i>p</i> < .05). No association was found between thermoplastification machines and the accuracy of the positioning of the attachments (<i>p</i> > .05). While small misadaptations between the aligners and the attachments were observed, the EVA templates performed better than the PETG templates.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The inaccuracy of the attachment positioning and the misadaptation of the aligners to the attachments were slight. The vacuum and pressure thermoplastification machines showed no difference in attachment positioning accuracy. The PETG template was better than the EVA template in the anterior region, but the EVA attachments presented a better adaptation to the aligners than the PETG attachments.</p>\n </section>\n </div>","PeriodicalId":19652,"journal":{"name":"Orthodontics & Craniofacial Research","volume":"27 S2","pages":"120-130"},"PeriodicalIF":2.4000,"publicationDate":"2024-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthodontics & Craniofacial Research","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/ocr.12843","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives
To evaluate the 3D accuracy of attachment positioning and the adaptation of aligners to attachments using in-house templates made with either polyethylene terephthalate glycol (PETG) or ethylene-vinyl acetate (EVA) and either pressure or vacuum thermoforming machines.
Materials and Methods
Overall, 140 test specimens were resin-printed. Templates for the attachment bonding were made with 1-mm EVA or 0.5-mm PETG laminates. Orthodontic aligners were manufactured with 0.75-mm PETG. The thermoplastification process was carried out using either vacuum or pressure machines. The positional differences between the virtual and bonded attachments were assessed in the X, Y and Z coordinates. The marginal adaptation between the aligners and the attachments was measured.
Results
Minor inaccuracies in the positioning of the attachments were observed in all combinations of thermoforming machines and plastic laminates used to fabricate the templates, mainly in the superior–inferior (Z) dimension. PETG performed better than EVA in the anterior region (p < .05). No association was found between thermoplastification machines and the accuracy of the positioning of the attachments (p > .05). While small misadaptations between the aligners and the attachments were observed, the EVA templates performed better than the PETG templates.
Conclusions
The inaccuracy of the attachment positioning and the misadaptation of the aligners to the attachments were slight. The vacuum and pressure thermoplastification machines showed no difference in attachment positioning accuracy. The PETG template was better than the EVA template in the anterior region, but the EVA attachments presented a better adaptation to the aligners than the PETG attachments.
期刊介绍:
Orthodontics & Craniofacial Research - Genes, Growth and Development is published to serve its readers as an international forum for the presentation and critical discussion of issues pertinent to the advancement of the specialty of orthodontics and the evidence-based knowledge of craniofacial growth and development. This forum is based on scientifically supported information, but also includes minority and conflicting opinions.
The objective of the journal is to facilitate effective communication between the research community and practicing clinicians. Original papers of high scientific quality that report the findings of clinical trials, clinical epidemiology, and novel therapeutic or diagnostic approaches are appropriate submissions. Similarly, we welcome papers in genetics, developmental biology, syndromology, surgery, speech and hearing, and other biomedical disciplines related to clinical orthodontics and normal and abnormal craniofacial growth and development. In addition to original and basic research, the journal publishes concise reviews, case reports of substantial value, invited essays, letters, and announcements.
The journal is published quarterly. The review of submitted papers will be coordinated by the editor and members of the editorial board. It is policy to review manuscripts within 3 to 4 weeks of receipt and to publish within 3 to 6 months of acceptance.