Amit S Piple, Jennifer C Wang, William Hill, Matthew S Chen, Brandon S Gettleman, Kevin C Liu, Nathanael D Heckmann, Alexander B Christ
{"title":"Postoperative outcomes and trends in computer-navigated and robotic-assisted total hip arthroplasty.","authors":"Amit S Piple, Jennifer C Wang, William Hill, Matthew S Chen, Brandon S Gettleman, Kevin C Liu, Nathanael D Heckmann, Alexander B Christ","doi":"10.1177/11207000241264256","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>As the volume of technology-assisted total hip arthroplasty (THA) increases, there is a need to characterise the outcomes of robotic-assisted (RA) and computer-navigated (CN) THA. The goal of this study was to assess outcomes and opioid consumption following CN-THA and RA-THA compared to conventionally-instrumented (CON) THA.</p><p><strong>Methods: </strong>The Premier Database was queried for all patients who underwent primary, elective THA from 2015-2020. Patients were divided into 3 groups: CN, RA, or CON-THA. Yearly usage trends were assessed. Univariate and multivariate analyses were performed to assess the 90-day risk of postoperative complications. Opioid consumption was reported in morphine milligram equivalents (MME) for postoperative days (POD) 0 and 1.</p><p><strong>Results: </strong>Overall, 474,707 elective THAs were identified (95.7% CON, 2.1% CN, 2.2% RA. After accounting for confounders, CN-THA patients were at decreased risk for periprosthetic joint infection (PJI) (aOR: 0.55, <i>p</i> < 0.001) and dislocation (aOR 0.45, <i>p</i> < 0.001), but increased risk for blood transfusion (aOR 1.97, <0.001) compared to CON-THA. RA-THA patients were at decreased risk of dislocation (aOR:0.66, <i>p</i> < 0.001) but increased risk for transfusion (aOR 1.20, <i>p</i> < 0.001), prosthesis breakage (aOR 3.88, <i>p</i> < 0.001), and periprosthetic fracture (aOR 1.72, <i>p</i> < 0.001). Opioid consumption for CN-THA patients was lower on POD1 and lower for RA-THA patients POD0 and 2 compared to CON-THA.</p><p><strong>Discussion: </strong>CN-THA was associated with reduced rates of PJI and dislocation, but increased rates of blood transfusion while RA-THA was associated with decreased rates of dislocation, but increased rates of blood transfusion, prosthesis complications, and periprosthetic fracture compared to CON-THA. Technology-assisted THA was associated with lower postoperative opioid consumption.</p>","PeriodicalId":12911,"journal":{"name":"HIP International","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"HIP International","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11207000241264256","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/8 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: As the volume of technology-assisted total hip arthroplasty (THA) increases, there is a need to characterise the outcomes of robotic-assisted (RA) and computer-navigated (CN) THA. The goal of this study was to assess outcomes and opioid consumption following CN-THA and RA-THA compared to conventionally-instrumented (CON) THA.
Methods: The Premier Database was queried for all patients who underwent primary, elective THA from 2015-2020. Patients were divided into 3 groups: CN, RA, or CON-THA. Yearly usage trends were assessed. Univariate and multivariate analyses were performed to assess the 90-day risk of postoperative complications. Opioid consumption was reported in morphine milligram equivalents (MME) for postoperative days (POD) 0 and 1.
Results: Overall, 474,707 elective THAs were identified (95.7% CON, 2.1% CN, 2.2% RA. After accounting for confounders, CN-THA patients were at decreased risk for periprosthetic joint infection (PJI) (aOR: 0.55, p < 0.001) and dislocation (aOR 0.45, p < 0.001), but increased risk for blood transfusion (aOR 1.97, <0.001) compared to CON-THA. RA-THA patients were at decreased risk of dislocation (aOR:0.66, p < 0.001) but increased risk for transfusion (aOR 1.20, p < 0.001), prosthesis breakage (aOR 3.88, p < 0.001), and periprosthetic fracture (aOR 1.72, p < 0.001). Opioid consumption for CN-THA patients was lower on POD1 and lower for RA-THA patients POD0 and 2 compared to CON-THA.
Discussion: CN-THA was associated with reduced rates of PJI and dislocation, but increased rates of blood transfusion while RA-THA was associated with decreased rates of dislocation, but increased rates of blood transfusion, prosthesis complications, and periprosthetic fracture compared to CON-THA. Technology-assisted THA was associated with lower postoperative opioid consumption.
期刊介绍:
HIP International is the official journal of the European Hip Society. It is the only international, peer-reviewed, bi-monthly journal dedicated to diseases of the hip. HIP International considers contributions relating to hip surgery, traumatology of the hip, prosthetic surgery, biomechanics, and basic sciences relating to the hip. HIP International invites reviews from leading specialists with the aim of informing its readers of current evidence-based best practice.
The journal also publishes supplements containing proceedings of symposia, special meetings or articles of special educational merit.
HIP International is divided into six independent sections led by editors of the highest scientific merit. These sections are:
• Biomaterials
• Biomechanics
• Conservative Hip Surgery
• Paediatrics
• Primary and Revision Hip Arthroplasty
• Traumatology