Reproducibility for carotid wall segmentation using T1-weighted DANTE-SPACE sequence on high-resolution 3-T carotid MRI.

IF 1.1 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Acta radiologica Pub Date : 2024-10-01 Epub Date: 2024-08-08 DOI:10.1177/02841851241268467
So Yeon Won, Kijeong Lee, Ilah Shin, Hyun Seok Choi, Jai Ho Choi, Bum-Soo Kim, Yong Sam Shin
{"title":"Reproducibility for carotid wall segmentation using T1-weighted DANTE-SPACE sequence on high-resolution 3-T carotid MRI.","authors":"So Yeon Won, Kijeong Lee, Ilah Shin, Hyun Seok Choi, Jai Ho Choi, Bum-Soo Kim, Yong Sam Shin","doi":"10.1177/02841851241268467","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>T1-weighted (T1W) magnetic resonance imaging (MRI) using the delay alternating with nutation for excitation-sampling perfection with application-optimized contrasts using different flip angle evolution (DANTE-SPACE) is the preferred imaging technique for evaluation of the vessel wall.</p><p><strong>Purpose: </strong>To evaluate the intra- and inter-rater reproducibility of carotid wall segmentation on T1W DANTE-SPACE in patients with symptomatic (acute stroke or transient ischemic attack) internal carotid artery (ICA) stenosis.</p><p><strong>Material and methods: </strong>This prospective study included 25 patients with acute (≤3 months) stroke or transient ischemic attack and 50%-99% stenosis of the ICA. All patients underwent 3.0-T high-resolution carotid MRI. Two radiologists independently performed the manual segmentation of the vessel wall and inner lumen of the bilateral carotid artery on DANTE-SPACE. The intraclass correlation coefficient (ICC), Dice similarity coefficient (DSC), and Hausdorff distance (HD) were calculated.</p><p><strong>Results: </strong>The ICCs for intra-rater reproducibility of carotid wall volume, inner lumen volume, and normalized wall index were 0.965, 0.990, and 0.962, respectively. The ICCs for inter-rater reproducibility of carotid wall volume, inner lumen, and normalized wall index were 0.856, 0.981, and 0.904. DSC and HD for intra- and inter-rater reproducibility of carotid wall segmentation were as follows: 0.873 and 0.809 (DSC); and 0.079 and 0.118 (HD), respectively. For evaluation of reproducibility only in the carotid artery with symptomatic stenosis, the ICCs for intra- and inter-rater reproducibility indicated all perfect agreement.</p><p><strong>Conclusion: </strong>T1W DANTE-SPACE is a reproducible sequence for evaluation of the carotid wall using carotid MRI in patients with symptomatic ICA stenosis.</p>","PeriodicalId":7143,"journal":{"name":"Acta radiologica","volume":" ","pages":"1196-1204"},"PeriodicalIF":1.1000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta radiologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/02841851241268467","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/8 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: T1-weighted (T1W) magnetic resonance imaging (MRI) using the delay alternating with nutation for excitation-sampling perfection with application-optimized contrasts using different flip angle evolution (DANTE-SPACE) is the preferred imaging technique for evaluation of the vessel wall.

Purpose: To evaluate the intra- and inter-rater reproducibility of carotid wall segmentation on T1W DANTE-SPACE in patients with symptomatic (acute stroke or transient ischemic attack) internal carotid artery (ICA) stenosis.

Material and methods: This prospective study included 25 patients with acute (≤3 months) stroke or transient ischemic attack and 50%-99% stenosis of the ICA. All patients underwent 3.0-T high-resolution carotid MRI. Two radiologists independently performed the manual segmentation of the vessel wall and inner lumen of the bilateral carotid artery on DANTE-SPACE. The intraclass correlation coefficient (ICC), Dice similarity coefficient (DSC), and Hausdorff distance (HD) were calculated.

Results: The ICCs for intra-rater reproducibility of carotid wall volume, inner lumen volume, and normalized wall index were 0.965, 0.990, and 0.962, respectively. The ICCs for inter-rater reproducibility of carotid wall volume, inner lumen, and normalized wall index were 0.856, 0.981, and 0.904. DSC and HD for intra- and inter-rater reproducibility of carotid wall segmentation were as follows: 0.873 and 0.809 (DSC); and 0.079 and 0.118 (HD), respectively. For evaluation of reproducibility only in the carotid artery with symptomatic stenosis, the ICCs for intra- and inter-rater reproducibility indicated all perfect agreement.

Conclusion: T1W DANTE-SPACE is a reproducible sequence for evaluation of the carotid wall using carotid MRI in patients with symptomatic ICA stenosis.

在高分辨率 3-T 颈动脉磁共振成像上使用 T1 加权 DANTE-SPACE 序列进行颈动脉壁分割的再现性。
背景:目的:评估无症状(急性中风或短暂性脑缺血发作)颈内动脉(ICA)狭窄患者在T1W DANTE-SPACE上进行颈动脉壁分割的评分内和评分间可重复性:这项前瞻性研究包括25名急性(≤3个月)中风或短暂性脑缺血发作且颈内动脉狭窄50%-99%的患者。所有患者均接受了 3.0 T 高分辨率颈动脉磁共振成像检查。两名放射科医生在DANTE-SPACE上独立完成了双侧颈动脉血管壁和内腔的手动分割。计算了类内相关系数(ICC)、Dice相似性系数(DSC)和Hausdorff距离(HD):颈动脉壁容积、内腔容积和归一化壁指数的评分者内再现性 ICC 分别为 0.965、0.990 和 0.962。颈动脉壁容积、内腔容积和归一化壁指数的评分者间重现性 ICC 分别为 0.856、0.981 和 0.904。颈动脉壁分割的 DSC 和 HD 在评分者内部和评分者之间的重现性如下:分别为 0.873 和 0.809(DSC);0.079 和 0.118(HD)。仅对有症状狭窄的颈动脉进行重现性评估时,评分者内部和评分者之间的重现性ICCs显示完全一致:结论:T1W DANTE-SPACE 是使用颈动脉磁共振成像对有症状的 ICA 狭窄患者的颈动脉壁进行评估的可重复性序列。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta radiologica
Acta radiologica 医学-核医学
CiteScore
2.70
自引率
0.00%
发文量
170
审稿时长
3-8 weeks
期刊介绍: Acta Radiologica publishes articles on all aspects of radiology, from clinical radiology to experimental work. It is known for articles based on experimental work and contrast media research, giving priority to scientific original papers. The distinguished international editorial board also invite review articles, short communications and technical and instrumental notes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信