Nathan R. Blue MD, MSCI, Amanda A. Allshouse MS, Kimberly A. Moyle MD, MSCI, Keisha Dimick RDMS, Robert M. Silver MD
{"title":"A Pilot Study of Ultrasound Assessment of Umbilical Cord and Placental Vascular Flow for Cord Accident Stillbirth Prevention","authors":"Nathan R. Blue MD, MSCI, Amanda A. Allshouse MS, Kimberly A. Moyle MD, MSCI, Keisha Dimick RDMS, Robert M. Silver MD","doi":"10.1002/jum.16546","DOIUrl":null,"url":null,"abstract":"<div>\n \n <section>\n \n <h3> Objective</h3>\n \n <p>Our objective was to determine the feasibility and interobserver reliability of umbilical cord and placental arteriolar flow assessment in low-risk pregnancies near term.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>This was a prospective pilot study in low-risk pregnancies at 36 weeks with anterior placentas. We excluded any with an indication for antenatal testing or delivery before 39 weeks. Each participant underwent two ultrasounds by different examiners, which included arterial and venous velocimetry at three cord sites (fetal, free loop, and placental) in addition to maternal and fetal placental arterioles. The interobserver reliability was quantified using the Pearson correlation coefficient with that of standard clinical parameters serving as a benchmark for interpretation.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Among 53 participants scanned at 35<sup>6/7</sup>–37<sup>1/7</sup> weeks, the mean examination duration was 20.5 ± 4.2 minutes. Ascertainment success was high for measures at the free loop, placental cord insertion, and fetal placental arterioles (range 90.6%–99.1%) and was lower at the fetal cord insertion and maternal spiral arterioles (range 47.2%–87.7%). Interobserver reliability estimates for free-loop systolic/diastolic and pulsatility index ranged from 0.38 to 0.44. Interobserver reliability for experimental parameters varied by measurement site, and all were poor at the fetal insertion and in placental arterioles. Parameters had significant variation across cord sites (range 4.3%–21.7%).</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>In our cohort, flow assessments of the free loop, placental insertion, and placental arterioles are feasible, but interrater reliability varies by measurement type and cord site. Future studies are needed to establish feasibility and reliability in nonanterior placentation and to assess clinical relevance.</p>\n </section>\n </div>","PeriodicalId":17563,"journal":{"name":"Journal of Ultrasound in Medicine","volume":"43 11","pages":"2153-2162"},"PeriodicalIF":2.1000,"publicationDate":"2024-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jum.16546","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasound in Medicine","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jum.16546","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0
Abstract
Objective
Our objective was to determine the feasibility and interobserver reliability of umbilical cord and placental arteriolar flow assessment in low-risk pregnancies near term.
Methods
This was a prospective pilot study in low-risk pregnancies at 36 weeks with anterior placentas. We excluded any with an indication for antenatal testing or delivery before 39 weeks. Each participant underwent two ultrasounds by different examiners, which included arterial and venous velocimetry at three cord sites (fetal, free loop, and placental) in addition to maternal and fetal placental arterioles. The interobserver reliability was quantified using the Pearson correlation coefficient with that of standard clinical parameters serving as a benchmark for interpretation.
Results
Among 53 participants scanned at 356/7–371/7 weeks, the mean examination duration was 20.5 ± 4.2 minutes. Ascertainment success was high for measures at the free loop, placental cord insertion, and fetal placental arterioles (range 90.6%–99.1%) and was lower at the fetal cord insertion and maternal spiral arterioles (range 47.2%–87.7%). Interobserver reliability estimates for free-loop systolic/diastolic and pulsatility index ranged from 0.38 to 0.44. Interobserver reliability for experimental parameters varied by measurement site, and all were poor at the fetal insertion and in placental arterioles. Parameters had significant variation across cord sites (range 4.3%–21.7%).
Conclusion
In our cohort, flow assessments of the free loop, placental insertion, and placental arterioles are feasible, but interrater reliability varies by measurement type and cord site. Future studies are needed to establish feasibility and reliability in nonanterior placentation and to assess clinical relevance.
期刊介绍:
The Journal of Ultrasound in Medicine (JUM) is dedicated to the rapid, accurate publication of original articles dealing with all aspects of medical ultrasound, particularly its direct application to patient care but also relevant basic science, advances in instrumentation, and biological effects. The journal is an official publication of the American Institute of Ultrasound in Medicine and publishes articles in a variety of categories, including Original Research papers, Review Articles, Pictorial Essays, Technical Innovations, Case Series, Letters to the Editor, and more, from an international bevy of countries in a continual effort to showcase and promote advances in the ultrasound community.
Represented through these efforts are a wide variety of disciplines of ultrasound, including, but not limited to:
-Basic Science-
Breast Ultrasound-
Contrast-Enhanced Ultrasound-
Dermatology-
Echocardiography-
Elastography-
Emergency Medicine-
Fetal Echocardiography-
Gastrointestinal Ultrasound-
General and Abdominal Ultrasound-
Genitourinary Ultrasound-
Gynecologic Ultrasound-
Head and Neck Ultrasound-
High Frequency Clinical and Preclinical Imaging-
Interventional-Intraoperative Ultrasound-
Musculoskeletal Ultrasound-
Neurosonology-
Obstetric Ultrasound-
Ophthalmologic Ultrasound-
Pediatric Ultrasound-
Point-of-Care Ultrasound-
Public Policy-
Superficial Structures-
Therapeutic Ultrasound-
Ultrasound Education-
Ultrasound in Global Health-
Urologic Ultrasound-
Vascular Ultrasound