Serial Vascular Responses of Balloon-Expandable Stent With Biodegradable Film-Type Graft in a Rabbit Iliac Artery Dissection Model (BioGard Study).

IF 3 3区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Sang Min Park, Kyung-Chan Choi, Byeong Han Lee, Sang Yol Yoo, Christopher Y Kim
{"title":"Serial Vascular Responses of Balloon-Expandable Stent With Biodegradable Film-Type Graft in a Rabbit Iliac Artery Dissection Model (BioGard Study).","authors":"Sang Min Park, Kyung-Chan Choi, Byeong Han Lee, Sang Yol Yoo, Christopher Y Kim","doi":"10.4070/kcj.2024.0049","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong>Arterial dissection during endovascular therapy rarely occurs but can be lethal. A fabric-based covered graft stents yield poor clinical outcomes. A novel balloon-expandable stent with biodegradable film graft for overcoming these issues was evaluated in a rabbit iliac artery model.</p><p><strong>Method: </strong>Eighteen rabbits with iliac artery dissections were induced by balloon over-inflation on angiography (Ellis type 2 or 3) and treated using the test device (3.0×24 mm). Subsequently, survived twelve animals underwent histologic examinations and micro-computed tomography (CT) at 0, 2, 4, and 8 weeks and 3, 6, 9, and 12 months and angiography at one-year.</p><p><strong>Results: </strong>There were no adverse cardiovascular events during the one-year. Early-stage histologic examination revealed complete sealing of disrupted vessels by the device, exhibiting mural hematoma, peri-stent red thrombi, and dense infiltration of inflammatory cells. Mid- and long-term histologic examination showed patent stents with neointimal hyperplasia over the stents (% area stenosis: 11.8 at 2 weeks, 26.1 at 1 month, 29.7 at 3 months, 49.2 at 9 months, and 51.0 at 1 year), along with mild peri-strut inflammatory response (Grade: 1-2 at mid-term and 0-1 at long-term). The graft film became scarcely visible after six months. Both CT and angiography revealed no instances of thrombotic occlusion or in-stent restenosis (% diameter stenosis: 5.7 at 2 weeks, 12.3 at 1 month, 14.2 at 3 months, 25.1 at 9 months, and 26.6 at 1 year).</p><p><strong>Conclusions: </strong>The novel balloon-expandable stent with a biodegradable film graft demonstrates feasibility in managing severe artery dissection and preventing lethal vascular events in animal model.</p>","PeriodicalId":17850,"journal":{"name":"Korean Circulation Journal","volume":"54 8","pages":"499-512"},"PeriodicalIF":3.0000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11306422/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Circulation Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4070/kcj.2024.0049","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background and objectives: Arterial dissection during endovascular therapy rarely occurs but can be lethal. A fabric-based covered graft stents yield poor clinical outcomes. A novel balloon-expandable stent with biodegradable film graft for overcoming these issues was evaluated in a rabbit iliac artery model.

Method: Eighteen rabbits with iliac artery dissections were induced by balloon over-inflation on angiography (Ellis type 2 or 3) and treated using the test device (3.0×24 mm). Subsequently, survived twelve animals underwent histologic examinations and micro-computed tomography (CT) at 0, 2, 4, and 8 weeks and 3, 6, 9, and 12 months and angiography at one-year.

Results: There were no adverse cardiovascular events during the one-year. Early-stage histologic examination revealed complete sealing of disrupted vessels by the device, exhibiting mural hematoma, peri-stent red thrombi, and dense infiltration of inflammatory cells. Mid- and long-term histologic examination showed patent stents with neointimal hyperplasia over the stents (% area stenosis: 11.8 at 2 weeks, 26.1 at 1 month, 29.7 at 3 months, 49.2 at 9 months, and 51.0 at 1 year), along with mild peri-strut inflammatory response (Grade: 1-2 at mid-term and 0-1 at long-term). The graft film became scarcely visible after six months. Both CT and angiography revealed no instances of thrombotic occlusion or in-stent restenosis (% diameter stenosis: 5.7 at 2 weeks, 12.3 at 1 month, 14.2 at 3 months, 25.1 at 9 months, and 26.6 at 1 year).

Conclusions: The novel balloon-expandable stent with a biodegradable film graft demonstrates feasibility in managing severe artery dissection and preventing lethal vascular events in animal model.

球囊扩张支架与生物降解膜式移植物在兔髂动脉离断模型中的连续血管反应(BioGard 研究)。
背景和目的:动脉夹层在血管内治疗过程中很少发生,但可能是致命的。以织物为基础的覆膜移植支架临床效果不佳。为了克服这些问题,我们在兔子髂动脉模型中评估了一种新型球囊扩张支架和生物可降解薄膜移植物:方法:在血管造影(Ellis 2 型或 3 型)中通过球囊过度充气诱发 18 只髂动脉断裂的兔子,并使用测试装置(3.0×24 毫米)进行治疗。随后,存活的 12 只动物分别在 0、2、4 和 8 周以及 3、6、9 和 12 个月时接受了组织学检查和微型计算机断层扫描(CT),并在一年时接受了血管造影检查:结果:一年内未发生不良心血管事件。早期组织学检查显示,装置完全封闭了中断的血管,出现壁血肿、支架周围红色血栓和致密的炎性细胞浸润。中期和长期组织学检查显示支架通畅,支架上有新的内膜增生(狭窄面积百分比:2 周为 11.8%,1 个月为 26.1%,3 个月为 29.7%,9 个月为 49.2%,1 年为 51.0%),支架周围有轻微的炎症反应(中期为 1-2 级,长期为 0-1 级)。六个月后,移植物膜变得几乎不可见。CT 和血管造影检查均未发现血栓闭塞或支架内再狭窄(直径狭窄率:2 周为 5.7%,1 个月为 12.3%,3 个月为 14.2%,9 个月为 25.1%,1 年为 26.6%):结论:在动物模型中,新型球囊扩张支架与可降解薄膜移植物在处理严重动脉夹层和预防致命性血管事件方面具有可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Korean Circulation Journal
Korean Circulation Journal CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
4.90
自引率
17.20%
发文量
103
期刊介绍: Korean Circulation Journal is the official journal of the Korean Society of Cardiology, the Korean Pediatric Heart Society, the Korean Society of Interventional Cardiology, and the Korean Society of Heart Failure. Abbreviated title is ''Korean Circ J''. Korean Circulation Journal, established in 1971, is a professional, peer-reviewed journal covering all aspects of cardiovascular medicine, including original articles of basic research and clinical findings, review articles, editorials, images in cardiovascular medicine, and letters to the editor. Korean Circulation Journal is published monthly in English and publishes scientific and state-of-the-art clinical articles aimed at improving human health in general and contributing to the treatment and prevention of cardiovascular diseases in particular. The journal is published on the official website (https://e-kcj.org). It is indexed in PubMed, PubMed Central, Science Citation Index Expanded (SCIE, Web of Science), Scopus, EMBASE, Chemical Abstracts Service (CAS), Google Scholar, KoreaMed, KoreaMed Synapse and KoMCI, and easily available to wide international researchers
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信