The bacterial displacement test: an in vitro microbiological test for the evaluation of intermittent catheters and urinary tract infection.

IF 3.2 3区 生物学 Q2 BIOTECHNOLOGY & APPLIED MICROBIOLOGY
Kate Meredith, David Pollard, Victoria Mason, Ased Ali
{"title":"The bacterial displacement test: an in vitro microbiological test for the evaluation of intermittent catheters and urinary tract infection.","authors":"Kate Meredith, David Pollard, Victoria Mason, Ased Ali","doi":"10.1093/jambio/lxae201","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Intermittent catheters (ICs) are commonly used in bladder management, but catheter-associated urinary tract infections (CAUTIs) remain challenging. Insertion tips may reduce the risk of CAUTIs by minimizing bacterial transfer along the urinary tract. However, there are few laboratory tests to evaluate such technologies. We describe the use of an adapted in vitro urethra agar model to assess bacterial displacement by ICs.</p><p><strong>Methods and results: </strong>Simulated urethra agar channels (UACs) were prepared with catheter-specific sized channels in selective media specific to the challenge organisms. UACs were inoculated with Escherichia coli and Enterococcus faecalis before insertion of ICs, and enumeration of UAC sections was performed following insertion. Four ICs were evaluated: Cure Catheter® Closed System (CCS), VaPro Plus Pocket™, Bard® Touchless® Plus, and SpeediCath® Flex Set. CCS demonstrated significantly reduced bacterial displacement along the UACs compared to the other ICs and was also the only IC with undetectable levels of bacteria toward the end of the UAC (representing the proximal urethra).</p><p><strong>Conclusion: </strong>The bacterial displacement test demonstrated significant differences in bacterial transfer between the test ICs with insertion tips, which may reflect their different designs. This method is useful for evaluating CAUTI prevention technology and may help guide future technology innovations.</p>","PeriodicalId":15036,"journal":{"name":"Journal of Applied Microbiology","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Microbiology","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1093/jambio/lxae201","RegionNum":3,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: Intermittent catheters (ICs) are commonly used in bladder management, but catheter-associated urinary tract infections (CAUTIs) remain challenging. Insertion tips may reduce the risk of CAUTIs by minimizing bacterial transfer along the urinary tract. However, there are few laboratory tests to evaluate such technologies. We describe the use of an adapted in vitro urethra agar model to assess bacterial displacement by ICs.

Methods and results: Simulated urethra agar channels (UACs) were prepared with catheter-specific sized channels in selective media specific to the challenge organisms. UACs were inoculated with Escherichia coli and Enterococcus faecalis before insertion of ICs, and enumeration of UAC sections was performed following insertion. Four ICs were evaluated: Cure Catheter® Closed System (CCS), VaPro Plus Pocket™, Bard® Touchless® Plus, and SpeediCath® Flex Set. CCS demonstrated significantly reduced bacterial displacement along the UACs compared to the other ICs and was also the only IC with undetectable levels of bacteria toward the end of the UAC (representing the proximal urethra).

Conclusion: The bacterial displacement test demonstrated significant differences in bacterial transfer between the test ICs with insertion tips, which may reflect their different designs. This method is useful for evaluating CAUTI prevention technology and may help guide future technology innovations.

细菌置换试验:用于评估间歇性导尿管和尿路感染的体外微生物试验。
目的:间歇性导尿管(IC)常用于膀胱管理,但导尿管相关性尿路感染(CAUTI)仍是一项挑战。插入尖端可最大限度地减少细菌沿尿路转移,从而降低 CAUTI 的风险。然而,目前很少有实验室测试对此类技术进行评估。我们介绍了如何使用经过改良的体外尿道琼脂模型来评估集成电路的细菌转移情况:模拟尿道琼脂通道(UAC)是在针对挑战微生物的选择性培养基中用导管特异大小的通道制备的。在插入 IC 之前,先在 UAC 上接种大肠杆菌和粪大肠杆菌,插入 IC 后对 UAC 切片进行计数。对四种 IC 进行了评估:Cure Catheter® Closed System (CCS)、VaPro Plus PocketTM、Bard® Touchless® Plus 和 SpeediCath® Flex Set。与其他 IC 相比,CCS 显示沿 UAC 的细菌移位明显减少,也是唯一在 UAC 末端(代表近端尿道)检测不到细菌的 IC:细菌移位测试表明,带插入尖的测试集成电路在细菌转移方面存在显著差异,这可能反映了它们的不同设计。这种方法有助于评估 CAUTI 预防技术,并为未来的技术创新提供指导。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Applied Microbiology
Journal of Applied Microbiology 生物-生物工程与应用微生物
CiteScore
7.30
自引率
2.50%
发文量
427
审稿时长
2.7 months
期刊介绍: Journal of & Letters in Applied Microbiology are two of the flagship research journals of the Society for Applied Microbiology (SfAM). For more than 75 years they have been publishing top quality research and reviews in the broad field of applied microbiology. The journals are provided to all SfAM members as well as having a global online readership totalling more than 500,000 downloads per year in more than 200 countries. Submitting authors can expect fast decision and publication times, averaging 33 days to first decision and 34 days from acceptance to online publication. There are no page charges.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信