A 3D micro-CT assessment of composition and structure of bone tissue after vertical and horizontal alveolar ridge augmentation using CAD/CAM-customized titanium mesh
Alessandro Cucchi, Gregorio Marchiori, Maria Sartori, Milena Fini, Antonino Fiorino, Raffaele Donati, Giuseppe Corinaldesi, Melania Maglio
{"title":"A 3D micro-CT assessment of composition and structure of bone tissue after vertical and horizontal alveolar ridge augmentation using CAD/CAM-customized titanium mesh","authors":"Alessandro Cucchi, Gregorio Marchiori, Maria Sartori, Milena Fini, Antonino Fiorino, Raffaele Donati, Giuseppe Corinaldesi, Melania Maglio","doi":"10.1111/clr.14342","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objectives</h3>\n \n <p>To date, no studies have exploited micro-CT in humans to evaluate bone morphology and structure after bone augmentation with CAD/CAM-customized titanium mesh, in mandible and maxilla. The aim of this study was to assess the composition and microstructure of bone biopsy through micro-CT analysis.</p>\n </section>\n \n <section>\n \n <h3> Materials and Methods</h3>\n \n <p>Bone augmentation at both maxillary and mandible sites was performed on 30 patients randomly treated with customized mesh, either alone (M−) or covered with resorbable membrane (M+), in both cases filled 50:50 with autogenous bone and xenograft. After 6 months, biopsies were taken and micro-CT was performed on consecutive 1-mm-thick VOIs from coronal to apical side, measuring tissue volumes, trabecular thickness, spacing, and number.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>In both groups, irrespective of membrane use, bone tissue (M−: 29.76% vs. M+: 30.84%) and residual graft material (M−: 14.87% vs. M+: 13.11%) values were similar. Differences were site-related (maxillary vs. mandibular) with higher percentage of bone tissue and trabecular density of low-mineralized bone and overall bone in the mandible.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The composition and structure of bone tissue, as assessed by micro-CT after alveolar ridge augmentation using CAD/CAM-customized titanium meshes, showed similar features regardless of whether a collagen membrane was applied.</p>\n </section>\n </div>","PeriodicalId":10455,"journal":{"name":"Clinical Oral Implants Research","volume":"35 12","pages":"1546-1559"},"PeriodicalIF":4.8000,"publicationDate":"2024-08-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11629439/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Oral Implants Research","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/clr.14342","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives
To date, no studies have exploited micro-CT in humans to evaluate bone morphology and structure after bone augmentation with CAD/CAM-customized titanium mesh, in mandible and maxilla. The aim of this study was to assess the composition and microstructure of bone biopsy through micro-CT analysis.
Materials and Methods
Bone augmentation at both maxillary and mandible sites was performed on 30 patients randomly treated with customized mesh, either alone (M−) or covered with resorbable membrane (M+), in both cases filled 50:50 with autogenous bone and xenograft. After 6 months, biopsies were taken and micro-CT was performed on consecutive 1-mm-thick VOIs from coronal to apical side, measuring tissue volumes, trabecular thickness, spacing, and number.
Results
In both groups, irrespective of membrane use, bone tissue (M−: 29.76% vs. M+: 30.84%) and residual graft material (M−: 14.87% vs. M+: 13.11%) values were similar. Differences were site-related (maxillary vs. mandibular) with higher percentage of bone tissue and trabecular density of low-mineralized bone and overall bone in the mandible.
Conclusions
The composition and structure of bone tissue, as assessed by micro-CT after alveolar ridge augmentation using CAD/CAM-customized titanium meshes, showed similar features regardless of whether a collagen membrane was applied.
期刊介绍:
Clinical Oral Implants Research conveys scientific progress in the field of implant dentistry and its related areas to clinicians, teachers and researchers concerned with the application of this information for the benefit of patients in need of oral implants. The journal addresses itself to clinicians, general practitioners, periodontists, oral and maxillofacial surgeons and prosthodontists, as well as to teachers, academicians and scholars involved in the education of professionals and in the scientific promotion of the field of implant dentistry.