Evaluation of polymerization shrinkage stress and cuspal strain in natural and typodont teeth.

IF 1.5 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Brazilian oral research Pub Date : 2024-08-05 eCollection Date: 2024-01-01 DOI:10.1590/1807-3107bor-2024.vol38.0061
Luiza Santos Cardoso, Amanda Alves de Oliveira, Gabrielly D'Paula Muniz Barbosa, Maria Luisa Prazeres Ribeiro, Tainah Costa Firmiano, Crisnicaw Veríssimo
{"title":"Evaluation of polymerization shrinkage stress and cuspal strain in natural and typodont teeth.","authors":"Luiza Santos Cardoso, Amanda Alves de Oliveira, Gabrielly D'Paula Muniz Barbosa, Maria Luisa Prazeres Ribeiro, Tainah Costa Firmiano, Crisnicaw Veríssimo","doi":"10.1590/1807-3107bor-2024.vol38.0061","DOIUrl":null,"url":null,"abstract":"<p><p>To evaluate the polymerization shrinkage stress and cuspal strain (CS) generated in an artificial (typodont) and in a natural tooth using different resin composites. Twenty artificial and 20 extracted natural molars were selected. Each tooth was prepared with a 4x4 mm MOD cavity. The natural and typodont teeth were divided into four experimental groups (n=10), according to the resin composite used: Filtek Z100 (3M Oral Care) and Beautifil II LS (Shofu Dental). The cavities were filled using two horizontal increments and the CS (µS) was measured by the strain gauge method. Samples were sectioned into stick-shaped specimens and the bond strength (BS) (MPa) was evaluated using a microtensile BS test. Shrinkage stress and CS were analyzed using 3D finite element analysis. No difference was found between the type of teeth for the CS as shown by the pooled averages: Natural tooth: 541.2 A; Typodont model: 591.4 A. Filtek Z100 CS values were higher than those obtained for Beautifil II LS, regardless of the type of teeth. No statistical difference was found for the BS data. Adhesive failures were more prevalent (79.9%). High shrinkage stress values were observed for Filtek Z100 resin, regardless of tooth type. The CS of typodont teeth showed a shrinkage stress effect, generated during restoration, equivalent to that of natural teeth.</p>","PeriodicalId":9240,"journal":{"name":"Brazilian oral research","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2024-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian oral research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/1807-3107bor-2024.vol38.0061","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

To evaluate the polymerization shrinkage stress and cuspal strain (CS) generated in an artificial (typodont) and in a natural tooth using different resin composites. Twenty artificial and 20 extracted natural molars were selected. Each tooth was prepared with a 4x4 mm MOD cavity. The natural and typodont teeth were divided into four experimental groups (n=10), according to the resin composite used: Filtek Z100 (3M Oral Care) and Beautifil II LS (Shofu Dental). The cavities were filled using two horizontal increments and the CS (µS) was measured by the strain gauge method. Samples were sectioned into stick-shaped specimens and the bond strength (BS) (MPa) was evaluated using a microtensile BS test. Shrinkage stress and CS were analyzed using 3D finite element analysis. No difference was found between the type of teeth for the CS as shown by the pooled averages: Natural tooth: 541.2 A; Typodont model: 591.4 A. Filtek Z100 CS values were higher than those obtained for Beautifil II LS, regardless of the type of teeth. No statistical difference was found for the BS data. Adhesive failures were more prevalent (79.9%). High shrinkage stress values were observed for Filtek Z100 resin, regardless of tooth type. The CS of typodont teeth showed a shrinkage stress effect, generated during restoration, equivalent to that of natural teeth.

评估天然牙齿和矫正牙齿的聚合收缩应力和牙尖应变。
评估使用不同树脂复合材料在人工牙(类型牙)和天然牙中产生的聚合收缩应力和牙尖应变(CS)。选择 20 颗人工臼齿和 20 颗拔出的天然臼齿。每颗牙齿都准备了一个 4x4 毫米的 MOD 牙洞。根据所用树脂复合材料的不同,天然牙和类型牙被分为四个实验组(n=10):Filtek Z100(3M 口腔护理公司)和 Beautifil II LS(尚福齿科)。用两个水平增量填充龋洞,并用应变计法测量 CS(µS)。将样品切成棒状试样,使用微拉伸 BS 测试评估粘接强度 (BS) (兆帕)。采用三维有限元分析法对收缩应力和 CS 进行了分析。从集合平均值来看,不同类型的牙齿在 CS 方面没有差异:天然牙自然牙:541.2 A;暴牙模型:591.4 A:无论牙齿类型如何,Filtek Z100 的 CS 值都高于 Beautifil II LS 的 CS 值。BS 数据没有统计差异。粘合剂失效更普遍(79.9%)。Filtek Z100 树脂的收缩应力值较高,与牙齿类型无关。类型牙的 CS 在修复过程中产生的收缩应力效应与天然牙相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.70
自引率
4.00%
发文量
107
审稿时长
12 weeks
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信