Alignment Techniques in Total Knee Arthroplasty:Where do We Stand Today?

Q2 Medicine
Dhungana Hemanta, Jangid Subhash, Goyal Meghal
{"title":"Alignment Techniques in Total Knee Arthroplasty:Where do We Stand Today?","authors":"Dhungana Hemanta, Jangid Subhash, Goyal Meghal","doi":"10.24920/004372","DOIUrl":null,"url":null,"abstract":"<p><p>Achieving optimal alignment in total knee arthroplasty (TKA) is a critical factor in ensuring optimal outcomes and long-term implant survival. Traditionally, mechanical alignment has been favored to achieve neutral post-operative joint alignment. However, contemporary approaches, such as kinematic alignments and hybrid techniques including adjusted mechanical, restricted kinematic, inverse kinematic, and functional alignments, are gaining attention for their ability to restore native joint kinematics and anatomical alignment, potentially leading to enhanced functional outcomes and greater patient satisfaction. The ongoing debate on optimal alignment strategies considers the following factors: long-term implant durability, functional improvement, and resolution of individual anatomical variations. Furthermore, advancements of computer-navigated and robotic-assisted surgery has augmented the precision in implant positioning and objective measurements of soft tissue balance. Despite ongoing debates on balancing implant longevity and functional outcomes, there is an increasing advocacy for personalized alignment strategies that are tailored to individual anatomical variations. This review evaluates the spectrum of various alignment techniques in TKA, including mechanical alignment, patient-specific kinematic approaches, and emerging hybrid methods. Each technique is scrutinized based on its fundamental principles, procedural techniques, inherent advantages, and potential limitations, while identifying significant clinical gaps that underscore the need for further investigation.</p>","PeriodicalId":35615,"journal":{"name":"Chinese Medical Sciences Journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chinese Medical Sciences Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.24920/004372","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Achieving optimal alignment in total knee arthroplasty (TKA) is a critical factor in ensuring optimal outcomes and long-term implant survival. Traditionally, mechanical alignment has been favored to achieve neutral post-operative joint alignment. However, contemporary approaches, such as kinematic alignments and hybrid techniques including adjusted mechanical, restricted kinematic, inverse kinematic, and functional alignments, are gaining attention for their ability to restore native joint kinematics and anatomical alignment, potentially leading to enhanced functional outcomes and greater patient satisfaction. The ongoing debate on optimal alignment strategies considers the following factors: long-term implant durability, functional improvement, and resolution of individual anatomical variations. Furthermore, advancements of computer-navigated and robotic-assisted surgery has augmented the precision in implant positioning and objective measurements of soft tissue balance. Despite ongoing debates on balancing implant longevity and functional outcomes, there is an increasing advocacy for personalized alignment strategies that are tailored to individual anatomical variations. This review evaluates the spectrum of various alignment techniques in TKA, including mechanical alignment, patient-specific kinematic approaches, and emerging hybrid methods. Each technique is scrutinized based on its fundamental principles, procedural techniques, inherent advantages, and potential limitations, while identifying significant clinical gaps that underscore the need for further investigation.

全膝关节置换术中的对位技术:我们的现状如何?
在全膝关节置换术(TKA)中实现最佳对位是确保最佳治疗效果和植入物长期存活的关键因素。传统上,人们倾向于采用机械式对位来实现术后关节的中性对位。然而,运动学对位和混合技术(包括调整机械对位、限制性运动学对位、反向运动学对位和功能性对位)等现代方法因其能够恢复原始关节运动学和解剖学对位而日益受到关注,并有可能提高功能性治疗效果和患者满意度。目前关于最佳对位策略的争论主要考虑以下因素:植入物的长期耐久性、功能改善以及个体解剖变异的解决。此外,计算机导航和机器人辅助手术的发展也提高了种植体定位的精确度和软组织平衡的客观测量。尽管人们一直在争论如何平衡种植体的寿命和功能效果,但越来越多的人主张根据个体解剖变异制定个性化的对位策略。本综述评估了 TKA 中的各种对位技术,包括机械对位、患者特异性运动学方法和新兴的混合方法。每种技术都根据其基本原理、程序技术、固有优势和潜在局限性进行了仔细研究,同时找出了临床上的重大差距,强调了进一步研究的必要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Chinese Medical Sciences Journal
Chinese Medical Sciences Journal Medicine-Medicine (all)
CiteScore
2.40
自引率
0.00%
发文量
1275
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信