Transcending Patient Morphometry: Acromiohumeral Interval to Glenoid Ratio as a Universal Diagnostic Tool for Massive Rotator Cuff Tears.

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
Accounts of Chemical Research Pub Date : 2024-08-01 Epub Date: 2024-05-28 DOI:10.4055/cios23381
Chidchanok Sakdapanichkul, Napat Chantarapitak, Nichaphat Kasemwong, Janyavath Suwanalai, Triwish Wimolsate, Thunwarath Jirawasinroj, Thitiporn Sakolsujin, Pinkawas Kongmalai
{"title":"Transcending Patient Morphometry: Acromiohumeral Interval to Glenoid Ratio as a Universal Diagnostic Tool for Massive Rotator Cuff Tears.","authors":"Chidchanok Sakdapanichkul, Napat Chantarapitak, Nichaphat Kasemwong, Janyavath Suwanalai, Triwish Wimolsate, Thunwarath Jirawasinroj, Thitiporn Sakolsujin, Pinkawas Kongmalai","doi":"10.4055/cios23381","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Morphological differences among various ethnicities can significantly impact the reliability of acromiohumeral interval (AHI) measurements in diagnosing massive rotator cuff tears. This variation raises questions about the generalizability of AHI studies conducted in Western populations to the Asian population. Consequently, the primary objective of this study was to develop a novel parameter that can enhance the diagnosis of massive rotator cuff tears, irrespective of morphometric disparities between individuals of different ethnic backgrounds.</p><p><strong>Methods: </strong>A 10-year retrospective analysis of shoulder arthroscopic surgery patients was conducted, categorizing them into 3 groups based on intraoperative findings: those without rotator cuff tears, those with non-massive tears, and those with massive tears. AHI-glenoid ratio (AHIGR) was measured by individuals with varying academic backgrounds, and its diagnostic performance was compared to AHI. Sensitivity, specificity, accuracy, and intra- and inter-rater reliability were evaluated.</p><p><strong>Results: </strong>AHIGR exhibited significantly improved sensitivity, specificity, and accuracy as a diagnostic tool for massive rotator cuff tears, compared to AHI. A proposed cut-off point of AHIGR ≤ 0.2 yielded comparable results to AHI < 7 mm. Intra- and inter-rater reliability was excellent among different observers.</p><p><strong>Conclusions: </strong>AHIGR emerges as a promising diagnostic tool for massive rotator cuff tears, offering improved sensitivity and specificity compared to AHI. Its reproducibility among diverse observers underscores its potential clinical utility. While further research with larger and more diverse patient cohorts is necessary, AHIGR offers significant potential as a reference for enhancing the assessment of massive rotator cuff tears.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11262935/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4055/cios23381","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/28 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Morphological differences among various ethnicities can significantly impact the reliability of acromiohumeral interval (AHI) measurements in diagnosing massive rotator cuff tears. This variation raises questions about the generalizability of AHI studies conducted in Western populations to the Asian population. Consequently, the primary objective of this study was to develop a novel parameter that can enhance the diagnosis of massive rotator cuff tears, irrespective of morphometric disparities between individuals of different ethnic backgrounds.

Methods: A 10-year retrospective analysis of shoulder arthroscopic surgery patients was conducted, categorizing them into 3 groups based on intraoperative findings: those without rotator cuff tears, those with non-massive tears, and those with massive tears. AHI-glenoid ratio (AHIGR) was measured by individuals with varying academic backgrounds, and its diagnostic performance was compared to AHI. Sensitivity, specificity, accuracy, and intra- and inter-rater reliability were evaluated.

Results: AHIGR exhibited significantly improved sensitivity, specificity, and accuracy as a diagnostic tool for massive rotator cuff tears, compared to AHI. A proposed cut-off point of AHIGR ≤ 0.2 yielded comparable results to AHI < 7 mm. Intra- and inter-rater reliability was excellent among different observers.

Conclusions: AHIGR emerges as a promising diagnostic tool for massive rotator cuff tears, offering improved sensitivity and specificity compared to AHI. Its reproducibility among diverse observers underscores its potential clinical utility. While further research with larger and more diverse patient cohorts is necessary, AHIGR offers significant potential as a reference for enhancing the assessment of massive rotator cuff tears.

超越患者形态测量:肱骨盂与盂间比率作为肩袖大面积撕裂的通用诊断工具。
背景:不同种族之间的形态差异会严重影响肩峰肱骨间距(AHI)测量在诊断肩袖大面积撕裂时的可靠性。这种差异使人怀疑在西方人群中进行的 AHI 研究能否推广到亚洲人群中。因此,本研究的主要目的是开发一种新的参数,以提高对肩袖撕裂的诊断率,而不考虑不同种族背景的个体之间的形态差异:方法: 对肩关节镜手术患者进行了一项为期 10 年的回顾性分析,根据术中发现将患者分为 3 组:无肩袖撕裂者、非大块撕裂者和大块撕裂者。AHI-韧带比值(AHIGR)由具有不同学术背景的人员测量,其诊断性能与 AHI 进行了比较。对敏感性、特异性、准确性以及评分者内部和评分者之间的可靠性进行了评估:结果:与 AHI 相比,AHIGR 作为大面积肩袖撕裂诊断工具的灵敏度、特异性和准确性都有明显提高。AHIGR ≤ 0.2 的临界点与 AHI < 7 mm 的结果相当。不同观察者之间的内部和相互评分可靠性都非常好:结论:与 AHI 相比,AHIGR 具有更高的灵敏度和特异性,是一种很有前途的大面积肩袖撕裂诊断工具。不同观察者之间的可重复性强调了其潜在的临床实用性。虽然有必要对更大规模、更多样化的患者群体进行进一步研究,但 AHIGR 作为一种参考工具,在增强对肩袖撕裂的评估方面具有巨大潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信