Posterior approach to correct for focal plane offsets in lattice light-sheet structured illumination microscopy.

IF 3 3区 医学 Q2 BIOCHEMICAL RESEARCH METHODS
Journal of Biomedical Optics Pub Date : 2024-08-01 Epub Date: 2024-07-31 DOI:10.1117/1.JBO.29.8.086502
Yu Shi, Tim A Daugird, Wesley R Legant
{"title":"Posterior approach to correct for focal plane offsets in lattice light-sheet structured illumination microscopy.","authors":"Yu Shi, Tim A Daugird, Wesley R Legant","doi":"10.1117/1.JBO.29.8.086502","DOIUrl":null,"url":null,"abstract":"<p><strong>Significance: </strong>Lattice light-sheet structured illumination microscopy (latticeSIM) has proven highly effective in producing three-dimensional images with super resolution rapidly and with minimal photobleaching. However, due to the use of two separate objectives, sample-induced aberrations can result in an offset between the planes of excitation and detection, causing artifacts in the reconstructed images.</p><p><strong>Aim: </strong>We introduce a posterior approach to detect and correct the axial offset between the excitation and detection focal planes in latticeSIM and provide a method to minimize artifacts in the reconstructed images.</p><p><strong>Approach: </strong>We utilized the residual phase information within the overlap regions of the laterally shifted structured illumination microscopy information components in frequency space to retrieve the axial offset between the excitation and the detection focal planes in latticeSIM.</p><p><strong>Results: </strong>We validated our technique through simulations and experiments, encompassing a range of samples from fluorescent beads to subcellular structures of adherent cells. We also show that using transfer functions with the same axial offset as the one present during data acquisition results in reconstructed images with minimal artifacts and salvages otherwise unusable data.</p><p><strong>Conclusion: </strong>We envision that our method will be a valuable addition to restore image quality in latticeSIM datasets even for those acquired under non-ideal experimental conditions.</p>","PeriodicalId":15264,"journal":{"name":"Journal of Biomedical Optics","volume":"29 8","pages":"086502"},"PeriodicalIF":3.0000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11289499/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomedical Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1117/1.JBO.29.8.086502","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/31 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Significance: Lattice light-sheet structured illumination microscopy (latticeSIM) has proven highly effective in producing three-dimensional images with super resolution rapidly and with minimal photobleaching. However, due to the use of two separate objectives, sample-induced aberrations can result in an offset between the planes of excitation and detection, causing artifacts in the reconstructed images.

Aim: We introduce a posterior approach to detect and correct the axial offset between the excitation and detection focal planes in latticeSIM and provide a method to minimize artifacts in the reconstructed images.

Approach: We utilized the residual phase information within the overlap regions of the laterally shifted structured illumination microscopy information components in frequency space to retrieve the axial offset between the excitation and the detection focal planes in latticeSIM.

Results: We validated our technique through simulations and experiments, encompassing a range of samples from fluorescent beads to subcellular structures of adherent cells. We also show that using transfer functions with the same axial offset as the one present during data acquisition results in reconstructed images with minimal artifacts and salvages otherwise unusable data.

Conclusion: We envision that our method will be a valuable addition to restore image quality in latticeSIM datasets even for those acquired under non-ideal experimental conditions.

在晶格光片结构照明显微镜中校正焦平面偏移的后置方法。
意义重大:格子光片结构照明显微镜(latticeSIM)已被证明在快速生成具有超分辨率的三维图像方面非常有效,而且光漂白极少。然而,由于使用两个独立的物镜,样品引起的像差会导致激发平面和检测平面之间的偏移,从而在重建图像中造成伪影。目的:我们介绍了一种后发方法,用于检测和纠正晶格光片结构照明显微镜(latticeSIM)中激发焦点平面和检测焦点平面之间的轴向偏移,并提供了一种方法,可最大限度地减少重建图像中的伪影:方法:我们利用频率空间中横向偏移的结构照明显微镜信息分量重叠区域内的残留相位信息来检索 latticeSIM 中激发焦平面和检测焦平面之间的轴向偏移:我们通过模拟和实验验证了我们的技术,涵盖了从荧光珠到粘附细胞亚细胞结构等一系列样品。结果:我们通过模拟和实验验证了我们的技术,涵盖了从荧光珠到粘附细胞的亚细胞结构等一系列样品。我们还证明,使用与数据采集时相同轴向偏移的传递函数,重建的图像可以将伪影降到最低,并挽救无法使用的数据:我们认为,即使是在非理想的实验条件下获取的数据集,我们的方法也将成为恢复晶格SIM数据集图像质量的重要补充。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.40
自引率
5.70%
发文量
263
审稿时长
2 months
期刊介绍: The Journal of Biomedical Optics publishes peer-reviewed papers on the use of modern optical technology for improved health care and biomedical research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信