{"title":"Investigation of current guidelines for prescribing spectacles to children using a modified Delphi approach and the AGREE II tool.","authors":"Salma Wilson, Catherine Suttle, Rakhee Shah, Miriam Conway, Irene Ctori","doi":"10.1111/opo.13358","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to identify clinical guidelines that provide recommendations on prescribing refractive error correction in children, evaluate the overall quality of these guidelines using the Appraisal of Guidelines for REsearch and Evaluation II (AGREE II) tool and subsequently gain consensus on the prescribing recommendations from high-quality guidelines using the modified Delphi technique.</p><p><strong>Methods: </strong>A comprehensive search for prescribing guidelines was conducted using databases and professional websites. The quality appraisal of eligible guidelines was undertaken by scoring the six AGREE II domains. Subsequently, the modified Delphi technique was used by 10 experts (sub-specialist optometrists, ophthalmologists and orthoptists) to gain consensus on the prescribing recommendation statements extracted from guidelines that had been identified as high quality. Three rounds were conducted in which agreement of these statements were scored using a 9-point Likert scale with a free-text option for any additional comments.</p><p><strong>Results: </strong>Five eligible guidelines were identified. The AGREE II tool demonstrated that the guidelines varied substantially in quality, with only one guideline identified as being of high quality. A total of 168 prescribing statements were reviewed in the Delphi procedure. Of these, 95 statements reached expert consensus as being appropriate prescribing recommendations.</p><p><strong>Conclusion: </strong>There is significant scope for improving current guidelines for prescribing refractive error correction in children. We used the modified Delphi technique to find points of agreement on prescribing recommendations to support professionals prescribing refractive error correction in children. We recommend that further work is needed to address gaps in the guidelines.</p>","PeriodicalId":19522,"journal":{"name":"Ophthalmic and Physiological Optics","volume":" ","pages":"1162-1187"},"PeriodicalIF":2.8000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic and Physiological Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/opo.13358","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/31 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: This study aimed to identify clinical guidelines that provide recommendations on prescribing refractive error correction in children, evaluate the overall quality of these guidelines using the Appraisal of Guidelines for REsearch and Evaluation II (AGREE II) tool and subsequently gain consensus on the prescribing recommendations from high-quality guidelines using the modified Delphi technique.
Methods: A comprehensive search for prescribing guidelines was conducted using databases and professional websites. The quality appraisal of eligible guidelines was undertaken by scoring the six AGREE II domains. Subsequently, the modified Delphi technique was used by 10 experts (sub-specialist optometrists, ophthalmologists and orthoptists) to gain consensus on the prescribing recommendation statements extracted from guidelines that had been identified as high quality. Three rounds were conducted in which agreement of these statements were scored using a 9-point Likert scale with a free-text option for any additional comments.
Results: Five eligible guidelines were identified. The AGREE II tool demonstrated that the guidelines varied substantially in quality, with only one guideline identified as being of high quality. A total of 168 prescribing statements were reviewed in the Delphi procedure. Of these, 95 statements reached expert consensus as being appropriate prescribing recommendations.
Conclusion: There is significant scope for improving current guidelines for prescribing refractive error correction in children. We used the modified Delphi technique to find points of agreement on prescribing recommendations to support professionals prescribing refractive error correction in children. We recommend that further work is needed to address gaps in the guidelines.
期刊介绍:
Ophthalmic & Physiological Optics, first published in 1925, is a leading international interdisciplinary journal that addresses basic and applied questions pertinent to contemporary research in vision science and optometry.
OPO publishes original research papers, technical notes, reviews and letters and will interest researchers, educators and clinicians concerned with the development, use and restoration of vision.