Research on Microclimate Optimization of Traditional Residential Buildings in Central Anhui Based on Humid and Hot Climate Characteristics and Regional Architectural Features
IF 3.1 3区 工程技术Q2 CONSTRUCTION & BUILDING TECHNOLOGY
Shan Wu, Lei Zhang, Ziteng Han, Chun Hu, Dongbing An
{"title":"Research on Microclimate Optimization of Traditional Residential Buildings in Central Anhui Based on Humid and Hot Climate Characteristics and Regional Architectural Features","authors":"Shan Wu, Lei Zhang, Ziteng Han, Chun Hu, Dongbing An","doi":"10.3390/buildings14082323","DOIUrl":null,"url":null,"abstract":"This study examines how building space, materials, and structure affect the microclimate of Liu Tong Xinglongzhuang in central Anhui, known for its hot, humid climate and distinct architecture. Using qualitative and quantitative methods, including field monitoring, PHOENICS simulation, and Ladybug Tools, the following conclusions were drawn: (1) Building materials: wood reduces indoor temperature; a glass roof over the patio lowers temperature and improves wind speed; and reducing tile area decreases solar radiation. (2) Building space: optimal comfort in stairwells is achieved with a length-to-width ratio of 1.5:1 and height-to-width ratio of 2:1; courtyards are most comfortable with a length-to-width ratio of 2.5:1 and height-to-width ratio of 1.5:1; walk-through halls are optimal with a length-to-width ratio of 2:1 and height-to-width ratio of 1.5:1; and wings achieve the highest comfort with a length-to-width ratio of 2.5:1 and height-to-width ratio of 1.5:1. (3) Building structure: optimal wind speed and temperature are achieved with specific window height-to-width ratios of 1:1 for exterior and 1.5:1 for interior windows; the lowest temperatures occur at 2:1 ratios; hexagonal exterior and circular interior windows maximize wind speed and temperature reduction; and smaller exterior door openings lower indoor temperatures and are best achieved with an interior door ratio of 2:1. These findings offer valuable data and methods for optimizing the microclimate of traditional houses, with significant practical implications.","PeriodicalId":48546,"journal":{"name":"Buildings","volume":null,"pages":null},"PeriodicalIF":3.1000,"publicationDate":"2024-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Buildings","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/buildings14082323","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
This study examines how building space, materials, and structure affect the microclimate of Liu Tong Xinglongzhuang in central Anhui, known for its hot, humid climate and distinct architecture. Using qualitative and quantitative methods, including field monitoring, PHOENICS simulation, and Ladybug Tools, the following conclusions were drawn: (1) Building materials: wood reduces indoor temperature; a glass roof over the patio lowers temperature and improves wind speed; and reducing tile area decreases solar radiation. (2) Building space: optimal comfort in stairwells is achieved with a length-to-width ratio of 1.5:1 and height-to-width ratio of 2:1; courtyards are most comfortable with a length-to-width ratio of 2.5:1 and height-to-width ratio of 1.5:1; walk-through halls are optimal with a length-to-width ratio of 2:1 and height-to-width ratio of 1.5:1; and wings achieve the highest comfort with a length-to-width ratio of 2.5:1 and height-to-width ratio of 1.5:1. (3) Building structure: optimal wind speed and temperature are achieved with specific window height-to-width ratios of 1:1 for exterior and 1.5:1 for interior windows; the lowest temperatures occur at 2:1 ratios; hexagonal exterior and circular interior windows maximize wind speed and temperature reduction; and smaller exterior door openings lower indoor temperatures and are best achieved with an interior door ratio of 2:1. These findings offer valuable data and methods for optimizing the microclimate of traditional houses, with significant practical implications.
期刊介绍:
BUILDINGS content is primarily staff-written and submitted information is evaluated by the editors for its value to the audience. Such information may be used in articles with appropriate attribution to the source. The editorial staff considers information on the following topics: -Issues directed at building owners and facility managers in North America -Issues relevant to existing buildings, including retrofits, maintenance and modernization -Solution-based content, such as tips and tricks -New construction but only with an eye to issues involving maintenance and operation We generally do not review the following topics because these are not relevant to our readers: -Information on the residential market with the exception of multifamily buildings -International news unrelated to the North American market -Real estate market updates or construction updates