Indoor CO2 phytoremediation using ornamental plants: A case study in Gresik, Indonesia

IF 1.7 4区 环境科学与生态学 Q3 ECOLOGY
Bieby Voijant Tangahu, Arkadiusz Przybysz, Mashudi Mashudi, Robert Popek, M. Rosichunal Ilmi Faz, Harmin Su‐listiyaning Titah, Ipung Fitri Purwanti, Mariia Pismanik, Sarwoko Mangkoedihardjo
{"title":"Indoor CO2 phytoremediation using ornamental plants: A case study in Gresik, Indonesia","authors":"Bieby Voijant Tangahu, Arkadiusz Przybysz, Mashudi Mashudi, Robert Popek, M. Rosichunal Ilmi Faz, Harmin Su‐listiyaning Titah, Ipung Fitri Purwanti, Mariia Pismanik, Sarwoko Mangkoedihardjo","doi":"10.1111/1440-1703.12511","DOIUrl":null,"url":null,"abstract":"Nowadays, people tend to spend more time indoor, especially in the home and office environment. Indoor air pollution such as CO<jats:sub>2</jats:sub> is prevalent in domestic rooms because it is emitted mostly from human metabolism and daily activities such as cooking. This study aims to examine the change of CO<jats:sub>2</jats:sub> concentration in the office of company providing logistic services located in Gresik (Indonesia) as a response to phytoremediation and evaluate the effectiveness of selected ornamental plants in controlling CO<jats:sub>2</jats:sub> level. The study employed two plants species namely <jats:italic>Maranta leuconeura</jats:italic> E. Morren and <jats:italic>Epipremnum aureum</jats:italic> (Linden &amp; André) G. S. Bunting to be placed in the first floor whereas the similar rooms in second floor were used as a control (without plants). The CO<jats:sub>2</jats:sub> level in all rooms have previously been measured and compared to quality standard. The required quantity of each plant was calculated based on CO<jats:sub>2</jats:sub> pollution load, office dimension, and CO<jats:sub>2</jats:sub> removal rate of plants. The presence of plants did not reduce CO<jats:sub>2</jats:sub> levels in the studied offices. In none of the offices with plants CO<jats:sub>2</jats:sub> concentrations dropped to the recommended levels. However, the plants maintained relatively stable CO<jats:sub>2</jats:sub> concentrations, unlike offices without plants, where the concentrations fluctuated and single peaks of increased concentrations were recorded. Room characteristics, exposure to sunlight, placement location of plants, and other external factors may affect efficiency of indoor phytoremediation.","PeriodicalId":11434,"journal":{"name":"Ecological Research","volume":"43 1","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2024-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ecological Research","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1111/1440-1703.12511","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ECOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Nowadays, people tend to spend more time indoor, especially in the home and office environment. Indoor air pollution such as CO2 is prevalent in domestic rooms because it is emitted mostly from human metabolism and daily activities such as cooking. This study aims to examine the change of CO2 concentration in the office of company providing logistic services located in Gresik (Indonesia) as a response to phytoremediation and evaluate the effectiveness of selected ornamental plants in controlling CO2 level. The study employed two plants species namely Maranta leuconeura E. Morren and Epipremnum aureum (Linden & André) G. S. Bunting to be placed in the first floor whereas the similar rooms in second floor were used as a control (without plants). The CO2 level in all rooms have previously been measured and compared to quality standard. The required quantity of each plant was calculated based on CO2 pollution load, office dimension, and CO2 removal rate of plants. The presence of plants did not reduce CO2 levels in the studied offices. In none of the offices with plants CO2 concentrations dropped to the recommended levels. However, the plants maintained relatively stable CO2 concentrations, unlike offices without plants, where the concentrations fluctuated and single peaks of increased concentrations were recorded. Room characteristics, exposure to sunlight, placement location of plants, and other external factors may affect efficiency of indoor phytoremediation.
利用观赏植物进行室内二氧化碳植物修复:印度尼西亚格雷斯克的案例研究
如今,人们倾向于在室内度过更多时间,尤其是在家庭和办公环境中。室内空气污染(如二氧化碳)在居室中十分普遍,因为它主要是由人类新陈代谢和日常活动(如烹饪)排放出来的。本研究旨在考察位于格雷斯克(印度尼西亚)的物流服务公司办公室内二氧化碳浓度的变化对植物修复的响应,并评估所选观赏植物在控制二氧化碳水平方面的效果。研究采用了两种植物,即 Maranta leuconeura E. Morren 和 Epipremnum aureum (Linden & André) G. S. Bunting,将其放置在一楼,而二楼的类似房间则作为对照(无植物)。所有房间的二氧化碳浓度都已测量过,并与质量标准进行了比较。根据二氧化碳污染负荷、办公室面积和植物的二氧化碳去除率,计算出了每种植物所需的数量。在所研究的办公室中,植物的存在并没有降低二氧化碳含量。在种植了植物的办公室中,二氧化碳浓度都没有下降到建议水平。不过,植物保持了相对稳定的二氧化碳浓度,不像没有植物的办公室,二氧化碳浓度会出现波动和单次峰值上升。室内特征、阳光照射、植物摆放位置和其他外部因素可能会影响室内植物修复的效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Ecological Research
Ecological Research 环境科学-生态学
CiteScore
4.40
自引率
5.00%
发文量
87
审稿时长
5.6 months
期刊介绍: Ecological Research has been published in English by the Ecological Society of Japan since 1986. Ecological Research publishes original papers on all aspects of ecology, in both aquatic and terrestrial ecosystems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信