Sensitive determination of neodymium isotope in seawater by multi-collector inductively coupled plasma mass spectrometry with ultrasound nebulization-dielectric barrier discharge vapor generation as sample introduction†

IF 3.1 2区 化学 Q2 CHEMISTRY, ANALYTICAL
Dongyong Li, Guanghao Cui, Shanshan Chen, Yifan Qiao, Qian Liu, Jing Zhang and Qian He
{"title":"Sensitive determination of neodymium isotope in seawater by multi-collector inductively coupled plasma mass spectrometry with ultrasound nebulization-dielectric barrier discharge vapor generation as sample introduction†","authors":"Dongyong Li, Guanghao Cui, Shanshan Chen, Yifan Qiao, Qian Liu, Jing Zhang and Qian He","doi":"10.1039/D4JA00106K","DOIUrl":null,"url":null,"abstract":"<p >In this work, a highly sensitive Nd isotopic analysis method by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) with ultrasound nebulization-dielectric barrier discharge (UNDBD) vapor generation as sample introduction is developed. The sensitivities of Nd isotopes determined by UNDBD are enhanced about 4.5 fold and 1.5 fold compared to conventional wet plasma and dry plasma, respectively, attributed to the generation of volatile Nd species during the dielectric barrier discharge (DBD) induced vapor generation process. Fractionation of Nd isotopes in UNDBD exhibits a mass-dependent characteristic, enabling successful correction of the <small><sup>143</sup></small>Nd/<small><sup>144</sup></small>Nd ratio using the <small><sup>146</sup></small>Nd/<small><sup>144</sup></small>Nd ratio with an exponential law. The minimum Nd concentration and volume required per analysis by UNDBD-MC-ICP-MS can be as low as 0.5 μg L<small><sup>−1</sup></small> and 600 μL, thereby minimizing the sampling volume for Nd isotopic analysis in open seawater to 0.7 L. Interferences from residual major ions in seawater, present at mg L<small><sup>−1</sup></small> level after pretreatment, are found to be negligible for Nd isotopic analysis by UNDBD-MC-ICP-MS. The long-term external precision (2RSD) for <small><sup>143</sup></small>Nd/<small><sup>144</sup></small>Nd with 1 μg L<small><sup>−1</sup></small> of Nd using this method is calculated as 64 ppm. The accuracy of <small><sup>143</sup></small>Nd/<small><sup>144</sup></small>Nd determined by this method has been successfully validated by Nd isotopic standard solutions of GSB 04-3258-2015 and GBW04440. The Nd isotopic ratios determined in several seawater samples by UNDBD are in agreement with results obtained by the dry plasma method. UNDBD demonstrates both higher sensitivity and precision for Nd isotopic analysis compared to wet plasma and dry plasma sample introduction methods, making it more suitable for analyzing open seawater samples with low Nd concentrations and less sampling volume.</p>","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":" 10","pages":" 2395-2401"},"PeriodicalIF":3.1000,"publicationDate":"2024-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/ja/d4ja00106k","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In this work, a highly sensitive Nd isotopic analysis method by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) with ultrasound nebulization-dielectric barrier discharge (UNDBD) vapor generation as sample introduction is developed. The sensitivities of Nd isotopes determined by UNDBD are enhanced about 4.5 fold and 1.5 fold compared to conventional wet plasma and dry plasma, respectively, attributed to the generation of volatile Nd species during the dielectric barrier discharge (DBD) induced vapor generation process. Fractionation of Nd isotopes in UNDBD exhibits a mass-dependent characteristic, enabling successful correction of the 143Nd/144Nd ratio using the 146Nd/144Nd ratio with an exponential law. The minimum Nd concentration and volume required per analysis by UNDBD-MC-ICP-MS can be as low as 0.5 μg L−1 and 600 μL, thereby minimizing the sampling volume for Nd isotopic analysis in open seawater to 0.7 L. Interferences from residual major ions in seawater, present at mg L−1 level after pretreatment, are found to be negligible for Nd isotopic analysis by UNDBD-MC-ICP-MS. The long-term external precision (2RSD) for 143Nd/144Nd with 1 μg L−1 of Nd using this method is calculated as 64 ppm. The accuracy of 143Nd/144Nd determined by this method has been successfully validated by Nd isotopic standard solutions of GSB 04-3258-2015 and GBW04440. The Nd isotopic ratios determined in several seawater samples by UNDBD are in agreement with results obtained by the dry plasma method. UNDBD demonstrates both higher sensitivity and precision for Nd isotopic analysis compared to wet plasma and dry plasma sample introduction methods, making it more suitable for analyzing open seawater samples with low Nd concentrations and less sampling volume.

Abstract Image

Abstract Image

以超声雾化-介质阻挡放电蒸汽发生作为样品导入的多收集器电感耦合等离子体质谱法灵敏测定海水中的钕同位素
本研究采用多收集器电感耦合等离子体质谱法(MC-ICP-MS),以超声雾化-介质阻挡放电(UNDBD)蒸汽发生作为样品导入,建立了一种高灵敏度钕同位素分析方法。与传统的湿等离子体和干等离子体相比,通过 UNDBD 测定钕同位素的灵敏度分别提高了约 4.5 倍和 1.5 倍,这归因于在介质阻挡放电(DBD)诱导的蒸汽发生过程中产生了挥发性钕物种。Nd 同位素在 UNDBD 中的分馏表现出质量依赖性特征,这使得利用具有指数规律的 146Nd/144Nd 比率修正 143Nd/144Nd 比率成为可能。使用 UNDBD-MC-ICP-MS 进行分析所需的最低钕浓度和体积可低至 0.5 μg L-1 和 600 μL,从而将开放海水中钕同位素分析的采样体积降至 0.7 L。用这种方法计算出的 1 μg L-1 Nd 的 143Nd/144Nd 长期外部精度(2RSD)为 64 ppm。该方法测定的 143Nd/144Nd 的准确度已通过 GSB 04-3258-2015 和 GBW04440 的钕同位素标准溶液成功验证。用 UNDBD 测定的几个海水样品的钕同位素比值与干等离子体法测定的结果一致。与湿等离子体和干等离子体样品引入法相比,UNDBD在钕同位素分析方面具有更高的灵敏度和精确度,因此更适用于分析钕浓度较低、采样量较少的开放式海水样品。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.20
自引率
26.50%
发文量
228
审稿时长
1.7 months
期刊介绍: Innovative research on the fundamental theory and application of spectrometric techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信