{"title":"Time-Domain Differential Protection Based on Operating and Restraining Trajectory Indices for Lines Connecting Battery Storage Energy Stations","authors":"Yingyu Liang;Cunyue Pan","doi":"10.35833/MPCE.2023.000618","DOIUrl":null,"url":null,"abstract":"Battery energy storage stations (BESSs) pose several challenges for both phasor-based differential protection and the newly-proposed time-domain differential protection. These challenges include low sensitivity and even rejection. Besides, the negative impact of various nonideal conditions, including current transformer (CT) saturation, errors, and outliers, on the security of differential protection remains an important problem. Motivated by the aforementioned issues, this study accounts for the trajectory distribution discrepancy on Cartesian plane under various conditions and proposes a time-domain differential protection method. In this paper, the trajectory formed by operating and restraining current samples is developed. Subsequently, after considering different operating states, the fault severity levels, and nonideal conditions, the variances in trajectory distribution between internal and external faults are extensively analyzed. On this basis, the Cartesian plane is divided into operating, uncertainty, and restraining zones. Further, the operating and restraining trajectory indices are meticulously designed and a protection criterion based on these indices is formed to accurately separate internal faults from other events, unaffected by CT saturation, errors, and outliers. The exceptional performance of the proposed protection method is extensively validated through PSCAD simulations and a hardware-in-the-loop testing platform. Regarding the dependability, sensitivity, and security, the proposed protection method outperforms three state-of-the-art differential protection methods.","PeriodicalId":51326,"journal":{"name":"Journal of Modern Power Systems and Clean Energy","volume":"12 4","pages":"1074-1086"},"PeriodicalIF":5.7000,"publicationDate":"2024-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10422879","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Modern Power Systems and Clean Energy","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10422879/","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
Battery energy storage stations (BESSs) pose several challenges for both phasor-based differential protection and the newly-proposed time-domain differential protection. These challenges include low sensitivity and even rejection. Besides, the negative impact of various nonideal conditions, including current transformer (CT) saturation, errors, and outliers, on the security of differential protection remains an important problem. Motivated by the aforementioned issues, this study accounts for the trajectory distribution discrepancy on Cartesian plane under various conditions and proposes a time-domain differential protection method. In this paper, the trajectory formed by operating and restraining current samples is developed. Subsequently, after considering different operating states, the fault severity levels, and nonideal conditions, the variances in trajectory distribution between internal and external faults are extensively analyzed. On this basis, the Cartesian plane is divided into operating, uncertainty, and restraining zones. Further, the operating and restraining trajectory indices are meticulously designed and a protection criterion based on these indices is formed to accurately separate internal faults from other events, unaffected by CT saturation, errors, and outliers. The exceptional performance of the proposed protection method is extensively validated through PSCAD simulations and a hardware-in-the-loop testing platform. Regarding the dependability, sensitivity, and security, the proposed protection method outperforms three state-of-the-art differential protection methods.
期刊介绍:
Journal of Modern Power Systems and Clean Energy (MPCE), commencing from June, 2013, is a newly established, peer-reviewed and quarterly published journal in English. It is the first international power engineering journal originated in mainland China. MPCE publishes original papers, short letters and review articles in the field of modern power systems with focus on smart grid technology and renewable energy integration, etc.