SISCOS in focal cortical dysplasia: localization and comparative analysis with MRI.

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS
ACS Applied Bio Materials Pub Date : 2024-11-01 Epub Date: 2024-07-26 DOI:10.1007/s00234-024-03434-8
Dikhra Khan, Sambit Sagar, Jasim Jaleel, Mohammad Umar, Madhavi Tripathi, Manjari Tripathi, M C Sharma, Chandrasekhar Bal
{"title":"SISCOS in focal cortical dysplasia: localization and comparative analysis with MRI.","authors":"Dikhra Khan, Sambit Sagar, Jasim Jaleel, Mohammad Umar, Madhavi Tripathi, Manjari Tripathi, M C Sharma, Chandrasekhar Bal","doi":"10.1007/s00234-024-03434-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study evaluates the efficacy of SISCOS (Subtraction ictal-interictal SPECT coregistered to SPECT) in localizing the epileptogenic zone (EZ) in focal cortical dysplasia (FCD), comparing its predictive performance with MRI and post-surgical outcomes based on ILAE classification.</p><p><strong>Methods: </strong>84 patients with drug refractory epilepsy (DRE) who were operated and had histopathology consistent with FCD, were included in the study. All patients had undergone a complete work-up including SISCOS and MRI for EZ localization, followed by discussion in the multidisciplinary epilepsy surgery meeting prior to surgery. Ictal & interictal perfusion SPECT studies were performed with Tc-99 m Ethylene Cysteinate Dimer (Tc-99 m ECD) followed by SISCOS analysis using SPM2 and Bioimage Suite 2.6. Concordance for localization was determined by comparing with the surgical resection site and post-surgical outcomes were assessed using the ILAE classification.</p><p><strong>Results: </strong>The concordance for EZ localization demonstrated by SISCOS was 73.8% and MRI was 82.1%. 52 patients (61.9%) had good surgical outcome and 31(59%) of these were FCD type 2. In patients with discordant MRI findings, SISCOS was able to provide localisation in 86% (13/15), with 69.2% showing good surgical outcomes. Sensitivity of SISCOS and MRI was 73% (95% CI = 59-84.8%) and 78% (95% CI = 67.5-90.3%) respectively with no significant difference between the two. In FCD type I, both SISCOS and MRI revealed a similar a sensitivity of 76.4% (95%CI = 50.1-93.2%). Concordant cases exhibited higher seizure-free odds ratios for both modalities.</p><p><strong>Conclusion: </strong>SISCOS is effective in localizing the EZ in FCD patients, comparable to MRI. Integrating SISCOS and MRI enhances lesion detection, especially in MRI discordant cases. A comprehensive diagnostic approach utilizing SISCOS and MRI can optimize the non-invasive pre-surgical assessment in DRE thereby guiding surgical decision-making in a resource-limited setting.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00234-024-03434-8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/26 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study evaluates the efficacy of SISCOS (Subtraction ictal-interictal SPECT coregistered to SPECT) in localizing the epileptogenic zone (EZ) in focal cortical dysplasia (FCD), comparing its predictive performance with MRI and post-surgical outcomes based on ILAE classification.

Methods: 84 patients with drug refractory epilepsy (DRE) who were operated and had histopathology consistent with FCD, were included in the study. All patients had undergone a complete work-up including SISCOS and MRI for EZ localization, followed by discussion in the multidisciplinary epilepsy surgery meeting prior to surgery. Ictal & interictal perfusion SPECT studies were performed with Tc-99 m Ethylene Cysteinate Dimer (Tc-99 m ECD) followed by SISCOS analysis using SPM2 and Bioimage Suite 2.6. Concordance for localization was determined by comparing with the surgical resection site and post-surgical outcomes were assessed using the ILAE classification.

Results: The concordance for EZ localization demonstrated by SISCOS was 73.8% and MRI was 82.1%. 52 patients (61.9%) had good surgical outcome and 31(59%) of these were FCD type 2. In patients with discordant MRI findings, SISCOS was able to provide localisation in 86% (13/15), with 69.2% showing good surgical outcomes. Sensitivity of SISCOS and MRI was 73% (95% CI = 59-84.8%) and 78% (95% CI = 67.5-90.3%) respectively with no significant difference between the two. In FCD type I, both SISCOS and MRI revealed a similar a sensitivity of 76.4% (95%CI = 50.1-93.2%). Concordant cases exhibited higher seizure-free odds ratios for both modalities.

Conclusion: SISCOS is effective in localizing the EZ in FCD patients, comparable to MRI. Integrating SISCOS and MRI enhances lesion detection, especially in MRI discordant cases. A comprehensive diagnostic approach utilizing SISCOS and MRI can optimize the non-invasive pre-surgical assessment in DRE thereby guiding surgical decision-making in a resource-limited setting.

Abstract Image

局灶性皮质发育不良的 SISCOS:定位及与核磁共振成像的对比分析。
目的:本研究评估了SISCOS(抽取发作期-发作间期SPECT与SPECT连接)在局灶性皮质发育不良(FCD)致痫区(EZ)定位中的疗效,并根据ILAE分类比较了SISCOS与MRI的预测性能和手术后疗效。所有患者均接受了完整的检查,包括SISCOS和用于EZ定位的核磁共振成像,并在手术前在多学科癫痫手术会议上进行了讨论。使用 Tc-99 m 乙撑半胱氨酸二聚体(Tc-99 m ECD)进行椎间期和发作间期灌注 SPECT 研究,然后使用 SPM2 和 Bioimage Suite 2.6 进行 SISCOS 分析。通过与手术切除部位的比较确定定位的一致性,并使用 ILAE 分类评估手术后的结果:SISCOS和MRI的EZ定位吻合率分别为73.8%和82.1%。52例患者(61.9%)手术效果良好,其中31例(59%)为FCD 2型。在磁共振成像结果不一致的患者中,SISCOS 能够为 86% 的患者(13/15)提供定位,其中 69.2% 的患者手术效果良好。SISCOS和磁共振成像的灵敏度分别为73%(95% CI = 59-84.8%)和78%(95% CI = 67.5-90.3%),两者之间无显著差异。在 FCD I 型中,SISCOS 和 MRI 的敏感性相似,均为 76.4% (95%CI = 50.1-93.2%)。结论:SISCOS对局部FCD有效:结论:SISCOS能有效定位FCD患者的EZ,其效果与磁共振成像相当。将 SISCOS 与核磁共振成像相结合可提高病灶检测率,尤其是在核磁共振成像不一致的病例中。利用 SISCOS 和 MRI 的综合诊断方法可以优化 DRE 的无创术前评估,从而在资源有限的情况下指导手术决策。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信