Michal Pruski, Susan O’Connell, Laura Knight, Rhys Morris
{"title":"Sedaconda ACD-S for Sedation with Volatile Anaesthetics in Intensive Care: A NICE Medical Technologies Guidance","authors":"Michal Pruski, Susan O’Connell, Laura Knight, Rhys Morris","doi":"10.1007/s40258-024-00903-2","DOIUrl":null,"url":null,"abstract":"<div><p>Intensive care unit (ICU) patients receive highly complex care and often require sedation as part of their management. ICU sedation has traditionally been delivered using intravenous (IV) agents due to the impractical use of anaesthetic machines in this setting, which are used to deliver volatile sedation. Sedaconda anaesthetic conserving device (ACD)-S (previously known as AnaConDa-S) is a device which allows for the delivery of volatile sedation via the majority of mechanical ventilators by being inserted in the breathing circuit where the heat and moisture exchanger is normally placed. The National Institute of Health and Care Excellence (NICE), as part of the Medical Technologies Evaluation Programme, considered the potential benefits of using Sedaconda ACD-S compared to standard IV sedation in ICU patients. Here we describe the evidence evaluation undertaken by NICE on this technology, supported by CEDAR. CEDAR considered the evidence present in 21 publications that compared the clinical outcomes of patients receiving Sedaconda ACD-S-delivered sedation and IV sedation, and critiqued the economic model provided by the manufacturer. Clinical expert input during the evaluation process was used extensively to ensure that the relevant clinical evidence was captured and that the economic model was suitable for the UK setting. Due to the uncertainty of the evidence, sensitivity analysis was carried out on the key economic inputs to ensure the reliability of the results. Economic modelling has shown that Sedaconda ACD-S–delivered isoflurane sedation is cost saving on a 30-day horizon compared to IV sedation by £3833.76 per adult patient and by £2837.41 per paediatric patient. Clinical evidence indicated that Sedaconda ACD-S-delivered isoflurane sedation is associated with faster patient wake-up times than standard of care. Consequently, NICE recommended Sedaconda ACD-S as an option for delivering sedation in the ICU setting, but noted that further research should inform whether Sedaconda ACD-S–delivered sedation is of benefit to any particular subgroup of patients.</p></div>","PeriodicalId":8065,"journal":{"name":"Applied Health Economics and Health Policy","volume":"22 6","pages":"805 - 813"},"PeriodicalIF":3.1000,"publicationDate":"2024-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Health Economics and Health Policy","FirstCategoryId":"3","ListUrlMain":"https://link.springer.com/article/10.1007/s40258-024-00903-2","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ECONOMICS","Score":null,"Total":0}
引用次数: 0
Abstract
Intensive care unit (ICU) patients receive highly complex care and often require sedation as part of their management. ICU sedation has traditionally been delivered using intravenous (IV) agents due to the impractical use of anaesthetic machines in this setting, which are used to deliver volatile sedation. Sedaconda anaesthetic conserving device (ACD)-S (previously known as AnaConDa-S) is a device which allows for the delivery of volatile sedation via the majority of mechanical ventilators by being inserted in the breathing circuit where the heat and moisture exchanger is normally placed. The National Institute of Health and Care Excellence (NICE), as part of the Medical Technologies Evaluation Programme, considered the potential benefits of using Sedaconda ACD-S compared to standard IV sedation in ICU patients. Here we describe the evidence evaluation undertaken by NICE on this technology, supported by CEDAR. CEDAR considered the evidence present in 21 publications that compared the clinical outcomes of patients receiving Sedaconda ACD-S-delivered sedation and IV sedation, and critiqued the economic model provided by the manufacturer. Clinical expert input during the evaluation process was used extensively to ensure that the relevant clinical evidence was captured and that the economic model was suitable for the UK setting. Due to the uncertainty of the evidence, sensitivity analysis was carried out on the key economic inputs to ensure the reliability of the results. Economic modelling has shown that Sedaconda ACD-S–delivered isoflurane sedation is cost saving on a 30-day horizon compared to IV sedation by £3833.76 per adult patient and by £2837.41 per paediatric patient. Clinical evidence indicated that Sedaconda ACD-S-delivered isoflurane sedation is associated with faster patient wake-up times than standard of care. Consequently, NICE recommended Sedaconda ACD-S as an option for delivering sedation in the ICU setting, but noted that further research should inform whether Sedaconda ACD-S–delivered sedation is of benefit to any particular subgroup of patients.
期刊介绍:
Applied Health Economics and Health Policy provides timely publication of cutting-edge research and expert opinion from this increasingly important field, making it a vital resource for payers, providers and researchers alike. The journal includes high quality economic research and reviews of all aspects of healthcare from various perspectives and countries, designed to communicate the latest applied information in health economics and health policy.
While emphasis is placed on information with practical applications, a strong basis of underlying scientific rigor is maintained.