Léna Pélissier, Duane Beraud, Bruno Pereira, Alexis Couret, Laurie Isacco, David Thivel
{"title":"Are anti-gravity treadmills reliable to explore exercise energy metabolism at low degrees of alleviation in normal-weight male individuals?","authors":"Léna Pélissier, Duane Beraud, Bruno Pereira, Alexis Couret, Laurie Isacco, David Thivel","doi":"10.3233/THC-240314","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Exploring the independent effect of mechanical discharge in response to weight loss (WL) seems necessary but remains highly challenging from a methodological point. Anti-gravity treadmills could be relevant to simulate a mechanical WL by body weight support (BWS), but their reliability remains unclear to properly explore exercise energy metabolism, especially at low degrees of alleviations.</p><p><strong>Objective: </strong>The study aimed to evaluate the accuracy and reproducibility of an anti-gravity treadmill to generate BWS, and the reproducibility of cardiometabolic responses to an exercise performed at low degrees of BWS on this device.</p><p><strong>Methods: </strong>Observed BWS of 18 normal-weight males was obtained twice at seven degrees of target BWS (i.e., 0, 3, 6, 9, 12, 15, 18%) using a digital scale inside the anti-gravity treadmill, and was compared to the expected BWS. Then, 15 of them performed 5-min bout of low-intensity walking exercise at these degrees of BWS in a randomized order, separated by 4-min rest. The exercise was identically repeated on three occasions separated by a minimum of 3 days. Energy metabolism and heart rate (HR) were measured throughout the exercise by indirect calorimetry and a HR monitor, respectively.</p><p><strong>Results: </strong>The observed BWS were significantly different from the expected BWS (p< 0.001), and there was a high inter- and intra-individual variability in BWS generated by the anti-gravity treadmill. Results showed an overall good reliability of VO2 (intraclass correlation coefficients (ICC) values ranging from 0.67 to 0.85) and HR (ICC > 0.8) in response to exercise. An effect of the degree of BWS was observed for VO2 (p< 0.001), illustrating reduced values at 15% and 18% of BWS compared to 0, 3, and 6%.</p><p><strong>Conclusions: </strong>Such device might not be adapted to simulate low degrees of WL in normal-weight males, particularly when it comes to the exploration of energy metabolism.</p>","PeriodicalId":48978,"journal":{"name":"Technology and Health Care","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-07-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technology and Health Care","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3233/THC-240314","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Exploring the independent effect of mechanical discharge in response to weight loss (WL) seems necessary but remains highly challenging from a methodological point. Anti-gravity treadmills could be relevant to simulate a mechanical WL by body weight support (BWS), but their reliability remains unclear to properly explore exercise energy metabolism, especially at low degrees of alleviations.
Objective: The study aimed to evaluate the accuracy and reproducibility of an anti-gravity treadmill to generate BWS, and the reproducibility of cardiometabolic responses to an exercise performed at low degrees of BWS on this device.
Methods: Observed BWS of 18 normal-weight males was obtained twice at seven degrees of target BWS (i.e., 0, 3, 6, 9, 12, 15, 18%) using a digital scale inside the anti-gravity treadmill, and was compared to the expected BWS. Then, 15 of them performed 5-min bout of low-intensity walking exercise at these degrees of BWS in a randomized order, separated by 4-min rest. The exercise was identically repeated on three occasions separated by a minimum of 3 days. Energy metabolism and heart rate (HR) were measured throughout the exercise by indirect calorimetry and a HR monitor, respectively.
Results: The observed BWS were significantly different from the expected BWS (p< 0.001), and there was a high inter- and intra-individual variability in BWS generated by the anti-gravity treadmill. Results showed an overall good reliability of VO2 (intraclass correlation coefficients (ICC) values ranging from 0.67 to 0.85) and HR (ICC > 0.8) in response to exercise. An effect of the degree of BWS was observed for VO2 (p< 0.001), illustrating reduced values at 15% and 18% of BWS compared to 0, 3, and 6%.
Conclusions: Such device might not be adapted to simulate low degrees of WL in normal-weight males, particularly when it comes to the exploration of energy metabolism.
期刊介绍:
Technology and Health Care is intended to serve as a forum for the presentation of original articles and technical notes, observing rigorous scientific standards. Furthermore, upon invitation, reviews, tutorials, discussion papers and minisymposia are featured. The main focus of THC is related to the overlapping areas of engineering and medicine. The following types of contributions are considered:
1.Original articles: New concepts, procedures and devices associated with the use of technology in medical research and clinical practice are presented to a readership with a widespread background in engineering and/or medicine. In particular, the clinical benefit deriving from the application of engineering methods and devices in clinical medicine should be demonstrated. Typically, full length original contributions have a length of 4000 words, thereby taking duly into account figures and tables.
2.Technical Notes and Short Communications: Technical Notes relate to novel technical developments with relevance for clinical medicine. In Short Communications, clinical applications are shortly described. 3.Both Technical Notes and Short Communications typically have a length of 1500 words.
Reviews and Tutorials (upon invitation only): Tutorial and educational articles for persons with a primarily medical background on principles of engineering with particular significance for biomedical applications and vice versa are presented. The Editorial Board is responsible for the selection of topics.
4.Minisymposia (upon invitation only): Under the leadership of a Special Editor, controversial or important issues relating to health care are highlighted and discussed by various authors.
5.Letters to the Editors: Discussions or short statements (not indexed).