Clinical evaluation of implants placed within or beyond the boundaries of the alveolar ridge preservation: a retrospective case series with 10 weeks of observations in 28 patients.

IF 2.2 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Young-Chang Ko, Ki-Tae Koo, Ling Li, Dongseob Lee, Yong-Moo Lee, Yang-Jo Seol, Tae-Hyung Kim, Jungwon Lee
{"title":"Clinical evaluation of implants placed within or beyond the boundaries of the alveolar ridge preservation: a retrospective case series with 10 weeks of observations in 28 patients.","authors":"Young-Chang Ko, Ki-Tae Koo, Ling Li, Dongseob Lee, Yong-Moo Lee, Yang-Jo Seol, Tae-Hyung Kim, Jungwon Lee","doi":"10.5051/jpis.2400800040","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study investigated the effect of implant vertical positioning within alveolar ridge preservation (ARP) sites on implant stability quotient (ISQ) values, which were measured 10 weeks post-implantation.</p><p><strong>Methods: </strong>Patients who underwent ARP using collagenized deproteinized bovine bone mineral, followed by implant placement in the posterior area, were divided into 2 groups: the within-ARP group and the beyond-ARP group. In the within-ARP group, osteotomy and implant placement occurred within the ARP boundary. In contrast, in the beyond-ARP group, these procedures were performed beyond the ARP boundary, incorporating 3 mm of pristine bone at the implant's apex. Bone quality was assessed by tactile sense, and both insertion torque during implant surgery and ISQ values at 10 weeks post-implant surgery were measured. Multiple linear regression analysis and Pearson correlation analysis were used to explore the relationship between insertion torque and ISQ values.</p><p><strong>Results: </strong>In total, 30 ARP sites in 28 patients were analyzed. There was no significant difference in bone quality, as determined by tactile sense, between the within-ARP and beyond-ARP groups. At the time of implant placement, the beyond-ARP group exhibited a higher insertion torque (33.33±13.39 Ncm) compared to the within-ARP group (17.08±11.17 Ncm). However, the ISQ values were similar between the 2 groups 10 weeks after implant placement. A positive correlation between insertion torque and ISQ values was confirmed at 10 weeks post-implant.</p><p><strong>Conclusions: </strong>The engagement of pristine bone may facilitate high insertion torque during the placement of implants in ARP sites. Nevertheless, by 10 weeks post-implantation, the ISQ values were found to be comparable, irrespective of the implant's position.</p>","PeriodicalId":48795,"journal":{"name":"Journal of Periodontal and Implant Science","volume":" ","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2024-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Periodontal and Implant Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5051/jpis.2400800040","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study investigated the effect of implant vertical positioning within alveolar ridge preservation (ARP) sites on implant stability quotient (ISQ) values, which were measured 10 weeks post-implantation.

Methods: Patients who underwent ARP using collagenized deproteinized bovine bone mineral, followed by implant placement in the posterior area, were divided into 2 groups: the within-ARP group and the beyond-ARP group. In the within-ARP group, osteotomy and implant placement occurred within the ARP boundary. In contrast, in the beyond-ARP group, these procedures were performed beyond the ARP boundary, incorporating 3 mm of pristine bone at the implant's apex. Bone quality was assessed by tactile sense, and both insertion torque during implant surgery and ISQ values at 10 weeks post-implant surgery were measured. Multiple linear regression analysis and Pearson correlation analysis were used to explore the relationship between insertion torque and ISQ values.

Results: In total, 30 ARP sites in 28 patients were analyzed. There was no significant difference in bone quality, as determined by tactile sense, between the within-ARP and beyond-ARP groups. At the time of implant placement, the beyond-ARP group exhibited a higher insertion torque (33.33±13.39 Ncm) compared to the within-ARP group (17.08±11.17 Ncm). However, the ISQ values were similar between the 2 groups 10 weeks after implant placement. A positive correlation between insertion torque and ISQ values was confirmed at 10 weeks post-implant.

Conclusions: The engagement of pristine bone may facilitate high insertion torque during the placement of implants in ARP sites. Nevertheless, by 10 weeks post-implantation, the ISQ values were found to be comparable, irrespective of the implant's position.

牙槽嵴保留范围内外植入种植体的临床评估:对 28 名患者进行为期 10 周观察的回顾性病例系列。
目的:本研究探讨了牙槽嵴保留(ARP)部位内种植体垂直定位对种植体稳定性商(ISQ)值的影响:使用胶原蛋白化牛骨矿物质进行 ARP,然后在后部植入种植体的患者分为两组:ARP 内组和 ARP 外组。在 ARP 内组中,截骨和种植体植入均在 ARP 边界内进行。而在 ARP 以外组,这些手术在 ARP 边界以外进行,在种植体顶端植入 3 毫米的原始骨。通过触觉评估骨质,并测量种植手术中的插入扭矩和种植手术后 10 周的 ISQ 值。采用多元线性回归分析和皮尔逊相关分析来探讨插入扭矩和 ISQ 值之间的关系:共分析了 28 名患者的 30 个 ARP 位点。根据触觉判断,ARP内组和ARP外组的骨质无明显差异。在植入种植体时,ARP 外组的插入扭矩(33.33±13.39 Ncm)高于 ARP 内组(17.08±11.17 Ncm)。然而,两组患者在种植体植入 10 周后的 ISQ 值相似。种植体植入后 10 周时,植入扭矩和 ISQ 值之间的正相关性得到了证实:结论:在 ARP 位点植入种植体时,原始骨质的参与可能会促进较高的植入扭矩。尽管如此,在种植体植入后 10 周,无论种植体的位置如何,ISQ 值都是相当的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Periodontal and Implant Science
Journal of Periodontal and Implant Science DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.30
自引率
5.30%
发文量
38
期刊介绍: Journal of Periodontal & Implant Science (JPIS) is a peer-reviewed and open-access journal providing up-to-date information relevant to professionalism of periodontology and dental implantology. JPIS is dedicated to global and extensive publication which includes evidence-based original articles, and fundamental reviews in order to cover a variety of interests in the field of periodontal as well as implant science.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信