Baseline lung allograft dysfunction after bilateral deceased-donor lung transplantation: A single-center experience in Japan

IF 2.4 Q2 RESPIRATORY SYSTEM
{"title":"Baseline lung allograft dysfunction after bilateral deceased-donor lung transplantation: A single-center experience in Japan","authors":"","doi":"10.1016/j.resinv.2024.07.009","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Baseline lung allograft dysfunction (BLAD) refers to a condition in which a lung transplant recipient does not achieve normal pulmonary function (i.e., forced expiratory volume in 1 s or forced vital capacity of &lt;80% of predicted values). Although BLAD is reportedly associated with a poor prognosis, the condition has not been examined in Japanese patients.</p></div><div><h3>Methods</h3><p>In this study, we retrospectively examined 38 Japanese adults who underwent bilateral lung transplantation from 2015 to 2022 in a single center.</p></div><div><h3>Results</h3><p>Twenty-one (55%) patients met the criteria for BLAD. No significant differences were found in recipient or donor factors between the BLAD and non-BLAD groups, but the donor–recipient ratio of the predicted vital capacity was lower in the BLAD group (<em>p</em> = 0.009). The intensive care unit length of stay, ventilator duration, and blood loss during transplant surgery were significantly higher in the BLAD group (<em>p</em> &lt; 0.05). No significant difference was found in survival. The median observation period was significantly shorter in the BLAD than non-BLAD group (744 vs.1192 days, respectively; <em>p</em> = 0.031). The time to reach the normal threshold of pulmonary function after lung transplantation varied among the patients, ranging from 6 months to 4 years.</p></div><div><h3>Conclusions</h3><p>The characteristics of these Japanese patients with BLAD were similar to those of other patients in previous reports. The effects of the observation period and donor–recipient age discrepancy on BLAD require further exploration.</p></div>","PeriodicalId":20934,"journal":{"name":"Respiratory investigation","volume":null,"pages":null},"PeriodicalIF":2.4000,"publicationDate":"2024-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2212534524001102/pdfft?md5=fac5a56079a944fe09beb28ab2c249b5&pid=1-s2.0-S2212534524001102-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Respiratory investigation","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2212534524001102","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Baseline lung allograft dysfunction (BLAD) refers to a condition in which a lung transplant recipient does not achieve normal pulmonary function (i.e., forced expiratory volume in 1 s or forced vital capacity of <80% of predicted values). Although BLAD is reportedly associated with a poor prognosis, the condition has not been examined in Japanese patients.

Methods

In this study, we retrospectively examined 38 Japanese adults who underwent bilateral lung transplantation from 2015 to 2022 in a single center.

Results

Twenty-one (55%) patients met the criteria for BLAD. No significant differences were found in recipient or donor factors between the BLAD and non-BLAD groups, but the donor–recipient ratio of the predicted vital capacity was lower in the BLAD group (p = 0.009). The intensive care unit length of stay, ventilator duration, and blood loss during transplant surgery were significantly higher in the BLAD group (p < 0.05). No significant difference was found in survival. The median observation period was significantly shorter in the BLAD than non-BLAD group (744 vs.1192 days, respectively; p = 0.031). The time to reach the normal threshold of pulmonary function after lung transplantation varied among the patients, ranging from 6 months to 4 years.

Conclusions

The characteristics of these Japanese patients with BLAD were similar to those of other patients in previous reports. The effects of the observation period and donor–recipient age discrepancy on BLAD require further exploration.

双侧已故供体肺移植术后肺异体功能障碍的基线:日本单中心经验。
背景:肺移植基线功能障碍(BLAD)是指肺移植受者的肺功能(即1秒内用力呼气容积或1秒内用力肺活量)不能达到正常水平的情况:在这项研究中,我们对 2015 年至 2022 年在一个中心接受双肺移植手术的 38 名日本成人进行了回顾性研究:21例(55%)患者符合BLAD标准。BLAD组和非BLAD组之间的受体或供体因素无明显差异,但BLAD组的供体-受体预测生命容量比值较低(P = 0.009)。BLAD组的重症监护室住院时间、呼吸机持续时间和移植手术中的失血量均明显高于非BLAD组(P 结论:BLAD组的移植手术中失血量明显高于非BLAD组(P = 0.009):这些日本 BLAD 患者的特征与之前报道的其他患者相似。需要进一步探讨观察期和供体与受体年龄差异对 BLAD 的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Respiratory investigation
Respiratory investigation RESPIRATORY SYSTEM-
CiteScore
4.90
自引率
6.50%
发文量
114
审稿时长
64 days
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信