Influence of muscle soft tissue and lower limbs on the vibration behavior of the entire spine inside the seated human body: A finite element study.

IF 1.7 4区 医学 Q3 ENGINEERING, BIOMEDICAL
Zhuangqi Lu, Ruichun Dong, Zhong Liu, Xiang Cheng, Yunqiang Guo, Kaifeng Zhang
{"title":"Influence of muscle soft tissue and lower limbs on the vibration behavior of the entire spine inside the seated human body: A finite element study.","authors":"Zhuangqi Lu, Ruichun Dong, Zhong Liu, Xiang Cheng, Yunqiang Guo, Kaifeng Zhang","doi":"10.1177/09544119241262500","DOIUrl":null,"url":null,"abstract":"<p><p>The objective of the study is to investigate the vibration behavior of the entire spine inside the human body and the influence of muscle soft tissue and lower limbs on spinal response under vertical whole-body vibration. This study conducted modal and random response analyses to simulate the modal displacements and stress of all intervertebral discs in the vertical principal mode in the skeleton, upper, and whole body. Additionally, the acceleration response of intervertebral discs under vertical random excitation was investigated. The results revealed that removing muscle soft tissue and lower limbs significantly changed the resonant frequency, modal displacement, and stress. Particularly, there was a rapid increase in vertical displacement of the lumbar spine in the skeleton model. The reason for that was due to the lack of soft tissue to provide stability, leading to significant lumbar spine bending. Under random excitation, the fore-aft acceleration of intervertebral discs in the skeleton model was considerably larger than that in the whole body, especially in the lumbar spine where it can reach up to four times higher. Conversely, the vertical response of the intervertebral discs inside the human body model was 1.4-2.4 times larger than that of the skeleton model. Muscle soft tissue contributes to the strength of the spine, reducing fore-aft response. The muscle soft tissue in the gluteal region, connected below the spine, can lower the vertical natural frequency and attenuate spinal impact. Although the lower limbs enhance spinal stability, stimulation from the feet can superimpose vibrational responses in the spine.</p>","PeriodicalId":20666,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","volume":" ","pages":"731-740"},"PeriodicalIF":1.7000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/09544119241262500","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/24 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The objective of the study is to investigate the vibration behavior of the entire spine inside the human body and the influence of muscle soft tissue and lower limbs on spinal response under vertical whole-body vibration. This study conducted modal and random response analyses to simulate the modal displacements and stress of all intervertebral discs in the vertical principal mode in the skeleton, upper, and whole body. Additionally, the acceleration response of intervertebral discs under vertical random excitation was investigated. The results revealed that removing muscle soft tissue and lower limbs significantly changed the resonant frequency, modal displacement, and stress. Particularly, there was a rapid increase in vertical displacement of the lumbar spine in the skeleton model. The reason for that was due to the lack of soft tissue to provide stability, leading to significant lumbar spine bending. Under random excitation, the fore-aft acceleration of intervertebral discs in the skeleton model was considerably larger than that in the whole body, especially in the lumbar spine where it can reach up to four times higher. Conversely, the vertical response of the intervertebral discs inside the human body model was 1.4-2.4 times larger than that of the skeleton model. Muscle soft tissue contributes to the strength of the spine, reducing fore-aft response. The muscle soft tissue in the gluteal region, connected below the spine, can lower the vertical natural frequency and attenuate spinal impact. Although the lower limbs enhance spinal stability, stimulation from the feet can superimpose vibrational responses in the spine.

肌肉软组织和下肢对坐姿人体内部整个脊柱振动行为的影响:有限元研究
本研究的目的是研究人体内部整个脊柱的振动行为,以及肌肉软组织和下肢对垂直全身振动下脊柱响应的影响。本研究进行了模态和随机响应分析,以模拟骨骼、上身和全身所有椎间盘在垂直主模态下的模态位移和应力。此外,还研究了椎间盘在垂直随机激励下的加速度响应。结果显示,去除肌肉软组织和下肢后,共振频率、模态位移和应力都发生了显著变化。特别是在骨架模型中,腰椎的垂直位移迅速增加。究其原因,是由于缺乏软组织提供稳定性,导致腰椎明显弯曲。在随机激励下,骨架模型中椎间盘的前后加速度大大高于全身,尤其是腰椎的前后加速度可高达全身的四倍。相反,人体模型内部椎间盘的垂直响应是骨架模型的 1.4-2.4 倍。肌肉软组织有助于增强脊柱的强度,降低前后响应。连接脊柱下方的臀部肌肉软组织可以降低垂直固有频率,减弱脊柱冲击力。虽然下肢增强了脊柱的稳定性,但来自脚部的刺激会叠加脊柱的振动反应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.60
自引率
5.60%
发文量
122
审稿时长
6 months
期刊介绍: The Journal of Engineering in Medicine is an interdisciplinary journal encompassing all aspects of engineering in medicine. The Journal is a vital tool for maintaining an understanding of the newest techniques and research in medical engineering.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信