{"title":"A mitochondria-targeted fluorescent sensor for imaging endogenous peroxynitrite changes in acute lung injury","authors":"","doi":"10.1016/j.talanta.2024.126561","DOIUrl":null,"url":null,"abstract":"<div><p>Acute lung injury (ALI) is a serious pulmonary inflammatory disease resulting from excessive reactive oxygen species (ROS) which could cause the damage of the alveolar epithelial cells and capillary endothelial cells. Peroxynitrite, as one of short-lived reactive oxygen species, is closely related to the process of ALI. Thus, it is important to monitor the fluctuation of peroxynitrite in living system for understanding the process of ALI. Herein, the novel mitochondria-targeted fluorescent probe <strong>BHMT</strong> was designed to respond to peroxynitrite and pH with distinct fluorescence properties respectively. The absorption spectrum of the probe <strong>BHMT</strong> exhibited a notable red shift as the pH value declined from 8.8 to 2.6. Upon reaction with peroxynitrite, BHMT had a significant increase of fluorescence intensity (63-fold) with maintaining a detection limit of only 43.7 nM. Furthermore, <strong>BHMT</strong> could detect the levels of endogenous peroxynitrite and image the intracellular pH in ratiometric channels utilizing cell imaging. In addition, <strong>BHMT</strong> was successfully applied to revealing the relationship between the peroxynitrite and the extent of ALI. Thus, these results indicated the probe <strong>BHMT</strong> could be a potential tool for diagnosing the early stage of ALI and revealed the peroxynitrite was likely to be a crucial therapeutic target in ALI treatment.</p></div>","PeriodicalId":435,"journal":{"name":"Talanta","volume":null,"pages":null},"PeriodicalIF":5.6000,"publicationDate":"2024-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0039914024009408","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Acute lung injury (ALI) is a serious pulmonary inflammatory disease resulting from excessive reactive oxygen species (ROS) which could cause the damage of the alveolar epithelial cells and capillary endothelial cells. Peroxynitrite, as one of short-lived reactive oxygen species, is closely related to the process of ALI. Thus, it is important to monitor the fluctuation of peroxynitrite in living system for understanding the process of ALI. Herein, the novel mitochondria-targeted fluorescent probe BHMT was designed to respond to peroxynitrite and pH with distinct fluorescence properties respectively. The absorption spectrum of the probe BHMT exhibited a notable red shift as the pH value declined from 8.8 to 2.6. Upon reaction with peroxynitrite, BHMT had a significant increase of fluorescence intensity (63-fold) with maintaining a detection limit of only 43.7 nM. Furthermore, BHMT could detect the levels of endogenous peroxynitrite and image the intracellular pH in ratiometric channels utilizing cell imaging. In addition, BHMT was successfully applied to revealing the relationship between the peroxynitrite and the extent of ALI. Thus, these results indicated the probe BHMT could be a potential tool for diagnosing the early stage of ALI and revealed the peroxynitrite was likely to be a crucial therapeutic target in ALI treatment.
期刊介绍:
Talanta provides a forum for the publication of original research papers, short communications, and critical reviews in all branches of pure and applied analytical chemistry. Papers are evaluated based on established guidelines, including the fundamental nature of the study, scientific novelty, substantial improvement or advantage over existing technology or methods, and demonstrated analytical applicability. Original research papers on fundamental studies, and on novel sensor and instrumentation developments, are encouraged. Novel or improved applications in areas such as clinical and biological chemistry, environmental analysis, geochemistry, materials science and engineering, and analytical platforms for omics development are welcome.
Analytical performance of methods should be determined, including interference and matrix effects, and methods should be validated by comparison with a standard method, or analysis of a certified reference material. Simple spiking recoveries may not be sufficient. The developed method should especially comprise information on selectivity, sensitivity, detection limits, accuracy, and reliability. However, applying official validation or robustness studies to a routine method or technique does not necessarily constitute novelty. Proper statistical treatment of the data should be provided. Relevant literature should be cited, including related publications by the authors, and authors should discuss how their proposed methodology compares with previously reported methods.