Efficacy of planned moderate to severe torque changes in maxillary central incisors with the Invisalign appliance: A retrospective investigation

IF 2.7 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
{"title":"Efficacy of planned moderate to severe torque changes in maxillary central incisors with the Invisalign appliance: A retrospective investigation","authors":"","doi":"10.1016/j.ajodo.2024.06.008","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>This study aimed to investigate whether there was a difference between the planned and achieved lingual root torque of the maxillary central incisors in patients treated with an initial series of Invisalign (Align Technology, Santa Clara, Calif) aligners in which &gt;10° change in the inclination of these teeth was prescribed via the ClinCheck facility.</div></div><div><h3>Methods</h3><div>The pretreatment, planned, and the digital models after wear of the initial series of aligners regarding adult patients who satisfied selection criteria and were treated using the Invisalign appliance were measured using the Geomagic Control X software (version 2017.0.3; 3D systems, Rock Hill, SC).</div></div><div><h3>Results</h3><div>A sample of 63 patients with 126 maxillary central incisors satisfied the inclusion criteria. The mean accuracy of the planned torque change of the maxillary central incisors that was achieved was 41.9%. A clinically significant shortfall (≥5°) was detected in 78.6% of the incisors, with the majority showing an underexpression between 10°-15°. Linear regression analyses indicated that weekly or biweekly wear protocols or the presence or absence of power ridges did not influence the accuracy of planned torque expression (<em>P</em> &gt;0.05).</div></div><div><h3>Conclusions</h3><div>The changes in torque expression with an initial series of Invisalign aligners were less than half of what was planned in patients in which at least a 10° change in lingual root torque of these teeth was prescribed. The presence of power ridges and the aligner change protocol did not appear to significantly affect the accuracy of maxillary central incisor torque expression.</div></div>","PeriodicalId":50806,"journal":{"name":"American Journal of Orthodontics and Dentofacial Orthopedics","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Orthodontics and Dentofacial Orthopedics","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0889540624002348","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

This study aimed to investigate whether there was a difference between the planned and achieved lingual root torque of the maxillary central incisors in patients treated with an initial series of Invisalign (Align Technology, Santa Clara, Calif) aligners in which >10° change in the inclination of these teeth was prescribed via the ClinCheck facility.

Methods

The pretreatment, planned, and the digital models after wear of the initial series of aligners regarding adult patients who satisfied selection criteria and were treated using the Invisalign appliance were measured using the Geomagic Control X software (version 2017.0.3; 3D systems, Rock Hill, SC).

Results

A sample of 63 patients with 126 maxillary central incisors satisfied the inclusion criteria. The mean accuracy of the planned torque change of the maxillary central incisors that was achieved was 41.9%. A clinically significant shortfall (≥5°) was detected in 78.6% of the incisors, with the majority showing an underexpression between 10°-15°. Linear regression analyses indicated that weekly or biweekly wear protocols or the presence or absence of power ridges did not influence the accuracy of planned torque expression (P >0.05).

Conclusions

The changes in torque expression with an initial series of Invisalign aligners were less than half of what was planned in patients in which at least a 10° change in lingual root torque of these teeth was prescribed. The presence of power ridges and the aligner change protocol did not appear to significantly affect the accuracy of maxillary central incisor torque expression.
使用隐适美(Invisalign)矫正器对上颌中切牙进行计划性中度至重度扭力改变的效果:回顾性研究。
前言:本研究旨在调查通过 ClinCheck 设备进行初始系列隐适美(Align Technology, Santa Clara, Calif)矫治器治疗的患者,其上颌中切牙倾斜度变化大于 10° 时,计划的上颌中切牙舌根扭力与实现的上颌中切牙舌根扭力之间是否存在差异:使用 Geomagic Control X 软件(2017.0.3 版;3D systems,Rock Hill,SC)对符合选择标准并使用隐适美(Invisalign)矫治器进行治疗的成年患者的预处理、计划和佩戴初始系列矫治器后的数字模型进行测量:符合纳入标准的上颌中切牙患者有 63 人,共 126 颗。上颌中切牙计划扭矩变化的平均准确率为 41.9%。在 78.6% 的切牙中发现了临床意义上的明显不足(≥5°),大多数切牙的不足程度在 10°-15° 之间。线性回归分析表明,每周或每两周戴牙一次、有无动力脊并不影响计划扭矩表达的准确性(P >0.05):结论:在对这些牙齿的舌根扭力至少有10°变化的患者中,初始系列隐适美矫正器的扭力变化不到计划的一半。动力脊的存在和矫治器更换方案似乎对上颌中切牙扭力表达的准确性没有显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.80
自引率
13.30%
发文量
432
审稿时长
66 days
期刊介绍: Published for more than 100 years, the American Journal of Orthodontics and Dentofacial Orthopedics remains the leading orthodontic resource. It is the official publication of the American Association of Orthodontists, its constituent societies, the American Board of Orthodontics, and the College of Diplomates of the American Board of Orthodontics. Each month its readers have access to original peer-reviewed articles that examine all phases of orthodontic treatment. Illustrated throughout, the publication includes tables, color photographs, and statistical data. Coverage includes successful diagnostic procedures, imaging techniques, bracket and archwire materials, extraction and impaction concerns, orthognathic surgery, TMJ disorders, removable appliances, and adult therapy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信