Ugur Nadir Karakulak, Levent Sahiner, Ergun Baris Kaya, Yusuf Ziya Sener, Ahmet Hakan Ates, Kudret Aytemir, Necla Ozer
{"title":"Prediction of New-Onset Atrial Fibrillation in Transcatheter Aortic Valve Implantation.","authors":"Ugur Nadir Karakulak, Levent Sahiner, Ergun Baris Kaya, Yusuf Ziya Sener, Ahmet Hakan Ates, Kudret Aytemir, Necla Ozer","doi":"10.6515/ACS.202407_40(4).20240201A","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study investigates the association between prolonged total atrial conduction time and the development of new-onset atrial fibrillation (AF) following transcatheter aortic valve implantation (TAVI).</p><p><strong>Methods: </strong>We enrolled 307 patients who underwent TAVI. Total atrial conduction time was calculated as the time between the onset of the P wave on the electrocardiography and the peak of the a' wave velocity (PA-TDI duration) on tissue Doppler imaging echocardiography.</p><p><strong>Results: </strong>A total of 263 patients were analyzed after excluding 44 with pre-existing AF. Of these 263 patients, 47 (17.8%) experienced new-onset AF after the TAVI procedure. The new-onset AF group had an older median age (80.6 vs. 77.5 years) and a higher incidence of paravalvular aortic regurgitation than those without AF (none 29.8%, mild 46.8%, moderate 23.4%). The new-onset AF group had increased end-systolic diameter (35.0 vs. 31.7 mm, p = 0.03), left atrial diameter (44.7 vs. 41.9 mm, p = 0.049), and PA-TDI duration (137.0 vs. 125.4 ms, p = 0.009). Older age, the presence of paravalvular aortic regurgitation, and prolonged PA-TDI duration were independently associated with new-onset AF in multivariate analysis. The optimal cut-off value for PA-TDI duration was 123.5 ms.</p><p><strong>Conclusions: </strong>AF in patients treated with TAVI may pose significant risks for morbidity and mortality. PA-TDI duration, a readily available echocardiographic parameter, can detect patients with a high risk of new-onset AF.</p>","PeriodicalId":6957,"journal":{"name":"Acta Cardiologica Sinica","volume":"40 4","pages":"437-444"},"PeriodicalIF":1.8000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11261363/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Cardiologica Sinica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.6515/ACS.202407_40(4).20240201A","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: This study investigates the association between prolonged total atrial conduction time and the development of new-onset atrial fibrillation (AF) following transcatheter aortic valve implantation (TAVI).
Methods: We enrolled 307 patients who underwent TAVI. Total atrial conduction time was calculated as the time between the onset of the P wave on the electrocardiography and the peak of the a' wave velocity (PA-TDI duration) on tissue Doppler imaging echocardiography.
Results: A total of 263 patients were analyzed after excluding 44 with pre-existing AF. Of these 263 patients, 47 (17.8%) experienced new-onset AF after the TAVI procedure. The new-onset AF group had an older median age (80.6 vs. 77.5 years) and a higher incidence of paravalvular aortic regurgitation than those without AF (none 29.8%, mild 46.8%, moderate 23.4%). The new-onset AF group had increased end-systolic diameter (35.0 vs. 31.7 mm, p = 0.03), left atrial diameter (44.7 vs. 41.9 mm, p = 0.049), and PA-TDI duration (137.0 vs. 125.4 ms, p = 0.009). Older age, the presence of paravalvular aortic regurgitation, and prolonged PA-TDI duration were independently associated with new-onset AF in multivariate analysis. The optimal cut-off value for PA-TDI duration was 123.5 ms.
Conclusions: AF in patients treated with TAVI may pose significant risks for morbidity and mortality. PA-TDI duration, a readily available echocardiographic parameter, can detect patients with a high risk of new-onset AF.
期刊介绍:
Acta Cardiologica Sinica welcomes all the papers in the fields related to cardiovascular medicine including basic research, vascular biology, clinical pharmacology, clinical trial, critical care medicine, coronary artery disease, interventional cardiology, arrythmia and electrophysiology, atherosclerosis, hypertension, cardiomyopathy and heart failure, valvular and structure cardiac disease, pediatric cardiology, cardiovascular surgery, and so on. We received papers from more than 20 countries and areas of the world. Currently, 40% of the papers were submitted to Acta Cardiologica Sinica from Taiwan, 20% from China, and 20% from the other countries and areas in the world. The acceptance rate for publication was around 50% in general.