Cross-Cultural Adaptation of The Indonesian Version Functional Assessment of Denture Instrument as a Measuring Tool for Complete Denture Functional Quality.

Q1 Dentistry
Arrad Ibrahim Rambey, Nina Ariani, Lindawati Soetanto Kusdhany
{"title":"Cross-Cultural Adaptation of The Indonesian Version Functional Assessment of Denture Instrument as a Measuring Tool for Complete Denture Functional Quality.","authors":"Arrad Ibrahim Rambey, Nina Ariani, Lindawati Soetanto Kusdhany","doi":"10.1055/s-0044-1786843","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong> Making good quality dentures is necessary to avoid patients' discomfort when adapting to new dentures. Several studies regarding the assessment of the quality of dentures have been carried out in many other countries, such as using the Functional Assessment of Dentures (FAD) by Anastassiadou. However, studies have yet to be conducted in Indonesia. This study aims to obtain a valid and reliable instrument to measure the quality of complete dentures (CDs). This study also aims to find out whether the functional quality of a CD measured with the Indonesian version of the FAD Instrument (PFGT) can affect patient satisfaction in receiving CD treatment (measured with Indonesian version of Patient's Denture Assessment [PDA-Id]) and to find contributing factors to the functional quality of a CD.</p><p><strong>Materials and methods: </strong> The study was conducted in two stages. The first stage was a qualitative study using cross-cultural adaptation methods and focus group discussions with experts. The second stage was a quantitative test with a total of 40 subjects for statistical analysis in the form of a kappa test, test-retest, Kuder-Richardson (KR) 20, and a correlation test between PDA-Id and PFG. Multivariate analysis was done to analyze contributing factors to the functional quality of CD.</p><p><strong>Results: </strong> The final instrument was obtained from the qualitative test, which was tested for content and face validation. The interrater kappa test result of 0.828 shows an almost perfect agreement. The results of the intrarater test-retest (0.564; <i>p</i> > 0.05; intraclass correlation coefficient 0.889) showed excellent instrument stability. The results of the internal consistency test with Kuder-Richardson 20 (1.08; KR > 1) showed good internal consistency. The correlation test results between PFGT and PDA-Id (0.044; <i>p</i> < 0.05) showed a positive correlation. Multivariate analysis showed a relationship between the quality of the CD, the length of time the CD was used, and the patient's satisfaction with CD treatment.</p><p><strong>Conclusion: </strong> The PFGT instrument is considered a valid and reliable tool to measure the functional quality of a denture that can distinguish between good and bad quality.</p>","PeriodicalId":12028,"journal":{"name":"European Journal of Dentistry","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0044-1786843","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Objective:  Making good quality dentures is necessary to avoid patients' discomfort when adapting to new dentures. Several studies regarding the assessment of the quality of dentures have been carried out in many other countries, such as using the Functional Assessment of Dentures (FAD) by Anastassiadou. However, studies have yet to be conducted in Indonesia. This study aims to obtain a valid and reliable instrument to measure the quality of complete dentures (CDs). This study also aims to find out whether the functional quality of a CD measured with the Indonesian version of the FAD Instrument (PFGT) can affect patient satisfaction in receiving CD treatment (measured with Indonesian version of Patient's Denture Assessment [PDA-Id]) and to find contributing factors to the functional quality of a CD.

Materials and methods:  The study was conducted in two stages. The first stage was a qualitative study using cross-cultural adaptation methods and focus group discussions with experts. The second stage was a quantitative test with a total of 40 subjects for statistical analysis in the form of a kappa test, test-retest, Kuder-Richardson (KR) 20, and a correlation test between PDA-Id and PFG. Multivariate analysis was done to analyze contributing factors to the functional quality of CD.

Results:  The final instrument was obtained from the qualitative test, which was tested for content and face validation. The interrater kappa test result of 0.828 shows an almost perfect agreement. The results of the intrarater test-retest (0.564; p > 0.05; intraclass correlation coefficient 0.889) showed excellent instrument stability. The results of the internal consistency test with Kuder-Richardson 20 (1.08; KR > 1) showed good internal consistency. The correlation test results between PFGT and PDA-Id (0.044; p < 0.05) showed a positive correlation. Multivariate analysis showed a relationship between the quality of the CD, the length of time the CD was used, and the patient's satisfaction with CD treatment.

Conclusion:  The PFGT instrument is considered a valid and reliable tool to measure the functional quality of a denture that can distinguish between good and bad quality.

将印尼版义齿功能评估工具作为全口义齿功能质量的测量工具进行跨文化改编。
目的:为避免患者在适应新假牙时出现不适,必须制作质量上乘的假牙。许多其他国家已经开展了多项有关假牙质量评估的研究,例如 Anastassiadou 使用假牙功能评估 (FAD) 进行的研究。然而,印尼尚未开展相关研究。本研究旨在获得一种有效可靠的工具来测量全口义齿(CD)的质量。本研究还旨在找出用印尼版 FAD 工具 (PFGT) 测量的全口义齿功能质量是否会影响患者接受全口义齿治疗的满意度(用印尼版患者义齿评估 (PDA-Id) 测量),并找出影响全口义齿功能质量的因素:研究分两个阶段进行。第一阶段是定性研究,采用了跨文化适应方法,并与专家进行了焦点小组讨论。第二阶段是定量测试,共有 40 名受试者参加,以卡帕测试、重复测试、Kuder-Richardson (KR) 20 和 PDA-Id 与 PFG 之间的相关性测试等形式进行统计分析。此外,还进行了多变量分析,以分析影响 CD 功能质量的因素:通过定性测试获得了最终工具,并对其进行了内容和表面验证。研究者之间的卡帕检验结果为 0.828,表明两者几乎完全一致。内部测试-重复测试的结果(0.564;p>0.05;类内相关系数 0.889)显示了工具极佳的稳定性。Kuder-Richardson 20 的内部一致性测试结果(1.08;KR > 1)显示了良好的内部一致性。PFGT 与 PDA-Id 之间的相关性测试结果(0.044;P 结论:PFGT 与 PDA-Id 之间的相关性测试结果为 0.044:PFGT 工具被认为是测量义齿功能质量的有效而可靠的工具,可以区分义齿质量的好坏。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
European Journal of Dentistry
European Journal of Dentistry Dentistry-Dentistry (all)
CiteScore
5.10
自引率
0.00%
发文量
161
期刊介绍: The European Journal of Dentistry is the official journal of the Dental Investigations Society, based in Turkey. It is a double-blinded peer-reviewed, Open Access, multi-disciplinary international journal addressing various aspects of dentistry. The journal''s board consists of eminent investigators in dentistry from across the globe and presents an ideal international composition. The journal encourages its authors to submit original investigations, reviews, and reports addressing various divisions of dentistry including oral pathology, prosthodontics, endodontics, orthodontics etc. It is available both online and in print.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信