{"title":"Detection of congestive heart failure based on Gramian angular field and two-dimensional symbolic phase permutation entropy","authors":"","doi":"10.1016/j.bbe.2024.06.005","DOIUrl":null,"url":null,"abstract":"<div><p><span>Congestive heart failure (CHF) is a serious threat to human health. Electrocardiogram (ECG) signals have been proven to be useful in the detection of CHF. However, the low amplitude and short duration of the ECG signals, as well as the superimposed noise during the real-time acquisition of the signal, seriously affect the CHF detection. To improve the detection rate of CHF, this paper proposes a congestive heart failure detection method based on Gramian angular field (GAF) and two-dimensional symbolic phase permutation entropy (SPPE2D). The significant advantage of this method is that it reduces the sensitivity to noise, and good performance can be obtained without denoising using raw ECG signals. We segment the original ECG signals into 2 s non-overlapping segments and convert them into images using the GAF method. Then, the SPPE2D algorithm is proposed to measure the complexity between </span>normal sinus rhythm<span> (NSR) and CHF, and analyze the anti-noise performance of the algorithm. Finally, the SPPE2D features of GAF images are computed and input into a support vector machine<span> (SVM) for CHF detection. Classification accuracy on the Massachusetts Institute of Technology − Beth Israel Hospital Normal Sinus Rhythm Database and Beth Israel Deaconess Medical Center Congestive Heart Failure Database is 99.59%, sensitivity is 99.42%, specificity is 99.80%, and F1-score is 99.62%. The accuracy of detecting CHF reach more than 97.75% in the other five CHF databases. The experimental results show that the method based on GAF and SPPE2D can effectively detect CHF by images of ECG signals and has good robustness. CHF can be detected using the 2 s sample lengths of ECG signals recording with high sensitivity, giving clinicians ample time to treat patients with CHF.</span></span></p></div>","PeriodicalId":55381,"journal":{"name":"Biocybernetics and Biomedical Engineering","volume":null,"pages":null},"PeriodicalIF":5.3000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biocybernetics and Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0208521624000469","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Congestive heart failure (CHF) is a serious threat to human health. Electrocardiogram (ECG) signals have been proven to be useful in the detection of CHF. However, the low amplitude and short duration of the ECG signals, as well as the superimposed noise during the real-time acquisition of the signal, seriously affect the CHF detection. To improve the detection rate of CHF, this paper proposes a congestive heart failure detection method based on Gramian angular field (GAF) and two-dimensional symbolic phase permutation entropy (SPPE2D). The significant advantage of this method is that it reduces the sensitivity to noise, and good performance can be obtained without denoising using raw ECG signals. We segment the original ECG signals into 2 s non-overlapping segments and convert them into images using the GAF method. Then, the SPPE2D algorithm is proposed to measure the complexity between normal sinus rhythm (NSR) and CHF, and analyze the anti-noise performance of the algorithm. Finally, the SPPE2D features of GAF images are computed and input into a support vector machine (SVM) for CHF detection. Classification accuracy on the Massachusetts Institute of Technology − Beth Israel Hospital Normal Sinus Rhythm Database and Beth Israel Deaconess Medical Center Congestive Heart Failure Database is 99.59%, sensitivity is 99.42%, specificity is 99.80%, and F1-score is 99.62%. The accuracy of detecting CHF reach more than 97.75% in the other five CHF databases. The experimental results show that the method based on GAF and SPPE2D can effectively detect CHF by images of ECG signals and has good robustness. CHF can be detected using the 2 s sample lengths of ECG signals recording with high sensitivity, giving clinicians ample time to treat patients with CHF.
期刊介绍:
Biocybernetics and Biomedical Engineering is a quarterly journal, founded in 1981, devoted to publishing the results of original, innovative and creative research investigations in the field of Biocybernetics and biomedical engineering, which bridges mathematical, physical, chemical and engineering methods and technology to analyse physiological processes in living organisms as well as to develop methods, devices and systems used in biology and medicine, mainly in medical diagnosis, monitoring systems and therapy. The Journal''s mission is to advance scientific discovery into new or improved standards of care, and promotion a wide-ranging exchange between science and its application to humans.