{"title":"BSA-Incorporated Sulphur and Nitrogen Doped Carbon dots (BSA-S,N-CDs) Based Platform for turn-on Fluorescence Detection of Histidine in Presence of Cu2+ ion","authors":"Aswathy A. O,&nbsp;Sony George","doi":"10.1007/s10876-024-02661-6","DOIUrl":null,"url":null,"abstract":"<div><p>Measuring of histidine levels can be used as an indication of the onset of diseases such as chronic kidney disease (CKD), anaemia, and cancer, etc. Due to its abnormal level in human diseases, histidine (His) monitoring has received a lot of interest. Here a feasible, sulphur and nitrogen-doped carbon dots-based (BSA-S,N-CDs) fluorescent switch-off-on nano sensor has been developed for the detection of histidine in an aqueous solution. The BSA-S,N-CDs was synthesized <i>via</i> microwave-assisted method from citric acid, urea, and bovine serum albumin (BSA). The blue fluorescence of BSA-S,N-CDs ( λ<sub>em</sub>: 444 nm) was quenched in the presence of Cu<sup>2+</sup> ion by static quenching and the quenched probe (BSA-S,N-CDs@Cu<sup>2+</sup> ) was used for the detection of histidine in the linear range from 0.29 to 2.33 mM. The limit of detection (LOD) and quantification (LOQ) of the probe was obtained as 34.55 µM and 115.18 µM respectively. The sensor exhibits good selectivity and less interference toward various biomolecules and ions. The BSA-S,N-CDs@Cu<sup>2+</sup> probe was used to detect histidine in spiked human serum and urine samples. Additionally, a paper strip-based sensor was developed to validate its practical applicability.</p></div>","PeriodicalId":618,"journal":{"name":"Journal of Cluster Science","volume":"35 7","pages":"2341 - 2352"},"PeriodicalIF":2.7000,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cluster Science","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s10876-024-02661-6","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
引用次数: 0

Abstract

Measuring of histidine levels can be used as an indication of the onset of diseases such as chronic kidney disease (CKD), anaemia, and cancer, etc. Due to its abnormal level in human diseases, histidine (His) monitoring has received a lot of interest. Here a feasible, sulphur and nitrogen-doped carbon dots-based (BSA-S,N-CDs) fluorescent switch-off-on nano sensor has been developed for the detection of histidine in an aqueous solution. The BSA-S,N-CDs was synthesized via microwave-assisted method from citric acid, urea, and bovine serum albumin (BSA). The blue fluorescence of BSA-S,N-CDs ( λem: 444 nm) was quenched in the presence of Cu2+ ion by static quenching and the quenched probe (BSA-S,N-CDs@Cu2+ ) was used for the detection of histidine in the linear range from 0.29 to 2.33 mM. The limit of detection (LOD) and quantification (LOQ) of the probe was obtained as 34.55 µM and 115.18 µM respectively. The sensor exhibits good selectivity and less interference toward various biomolecules and ions. The BSA-S,N-CDs@Cu2+ probe was used to detect histidine in spiked human serum and urine samples. Additionally, a paper strip-based sensor was developed to validate its practical applicability.

Abstract Image

基于 BSA 嵌入式硫氮掺杂碳点(BSA-S,N-CDs)的 Cu2+ 离子存在时组氨酸荧光检测平台
组氨酸水平的测量可作为慢性肾病(CKD)、贫血和癌症等疾病发病的征兆。由于组氨酸(His)在人类疾病中的异常含量,组氨酸(His)的监测受到了广泛关注。在此,我们开发了一种可行的、基于掺硫和掺氮碳点(BSA-S,N-CDs)的荧光开关式纳米传感器,用于检测水溶液中的组氨酸。BSA-S,N-CDs 是由柠檬酸、尿素和牛血清白蛋白(BSA)通过微波辅助方法合成的。在Cu2+离子存在下,BSA-S,N-CDs的蓝色荧光(λem: 444 nm)被静态淬灭,淬灭探针(BSA-S,N-CDs@Cu2+)用于检测组氨酸,线性范围为0.29-2.33 mM。探针的检测限(LOD)和定量限(LOQ)分别为 34.55 µM 和 115.18 µM。该传感器对各种生物大分子和离子具有良好的选择性和较少的干扰。利用 BSA-S,N-CDs@Cu2+探针检测了添加组氨酸的人体血清和尿液样品。此外,还开发了一种基于纸条的传感器,以验证其实际应用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Cluster Science
Journal of Cluster Science 化学-无机化学与核化学
CiteScore
6.70
自引率
0.00%
发文量
166
审稿时长
3 months
期刊介绍: The journal publishes the following types of papers: (a) original and important research; (b) authoritative comprehensive reviews or short overviews of topics of current interest; (c) brief but urgent communications on new significant research; and (d) commentaries intended to foster the exchange of innovative or provocative ideas, and to encourage dialogue, amongst researchers working in different cluster disciplines.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信