{"title":"Utilization of international normalized ratio-derived formula to predict plasma rivaroxaban level—Validation study and real-world experience","authors":"Chun-fun Sin, Ka-ping Wong, Chun Wah Siu, Tsz-fu Wong, Hoi-man Wong","doi":"10.1111/ijlh.14347","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Introduction</h3>\n \n <p>Specific assays of plasma rivaroxaban level are not always readily available with short turnaround time, which hamper the management of urgent clinical situations. In this study, we aimed to build a predictive formula of plasma rivaroxaban levels from international normalized ratio (INR) value and validated in real world clinical situations.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Ninety-four patients who were taking rivaroxaban participated in the study. Patients were randomized into testing cohort and validation cohorts. The prediction formula was built from the testing cohort and then validated in validation cohort. The predictive performance was further validated on real-world clinical requests.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The root mean square error (RMSE) of the predictive formula for the testing and validation cohorts were 61.81 and 69.32 ng/mL, respectively. The sensitivity and specificity for the formula to predict the threshold plasma rivaroxaban level of 75 ng/mL were 95% (95% CI: 85.4%–100%) and 87.5% (95% CI: 71.3%–100%), respectively, in real-world clinical situations.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>Plasma rivaroxaban level of threshold level of 75 ng/mL can be calculated from prediction formula by INR value with satisfactory accuracy and it can be used to guide the decision for reversal.</p>\n </section>\n </div>","PeriodicalId":14120,"journal":{"name":"International Journal of Laboratory Hematology","volume":"46 6","pages":"1101-1108"},"PeriodicalIF":2.2000,"publicationDate":"2024-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/ijlh.14347","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Laboratory Hematology","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/ijlh.14347","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction
Specific assays of plasma rivaroxaban level are not always readily available with short turnaround time, which hamper the management of urgent clinical situations. In this study, we aimed to build a predictive formula of plasma rivaroxaban levels from international normalized ratio (INR) value and validated in real world clinical situations.
Methods
Ninety-four patients who were taking rivaroxaban participated in the study. Patients were randomized into testing cohort and validation cohorts. The prediction formula was built from the testing cohort and then validated in validation cohort. The predictive performance was further validated on real-world clinical requests.
Results
The root mean square error (RMSE) of the predictive formula for the testing and validation cohorts were 61.81 and 69.32 ng/mL, respectively. The sensitivity and specificity for the formula to predict the threshold plasma rivaroxaban level of 75 ng/mL were 95% (95% CI: 85.4%–100%) and 87.5% (95% CI: 71.3%–100%), respectively, in real-world clinical situations.
Conclusion
Plasma rivaroxaban level of threshold level of 75 ng/mL can be calculated from prediction formula by INR value with satisfactory accuracy and it can be used to guide the decision for reversal.
期刊介绍:
The International Journal of Laboratory Hematology provides a forum for the communication of new developments, research topics and the practice of laboratory haematology.
The journal publishes invited reviews, full length original articles, and correspondence.
The International Journal of Laboratory Hematology is the official journal of the International Society for Laboratory Hematology, which addresses the following sub-disciplines: cellular analysis, flow cytometry, haemostasis and thrombosis, molecular diagnostics, haematology informatics, haemoglobinopathies, point of care testing, standards and guidelines.
The journal was launched in 2006 as the successor to Clinical and Laboratory Hematology, which was first published in 1979. An active and positive editorial policy ensures that work of a high scientific standard is reported, in order to bridge the gap between practical and academic aspects of laboratory haematology.