Ivan Onone Gialain, Marlene Kasumi Gantier-Takano, Leonardo Folmer Rodrigues da Silva, Marina Guimarães Roscoe, Otavio Henrique Pinhata-Baptista, Josete Barbosa Cruz Meira, Alex Siu Lun Fok
{"title":"A finite element study on the risk of bone loss around posterior short implants in an atrophic mandible.","authors":"Ivan Onone Gialain, Marlene Kasumi Gantier-Takano, Leonardo Folmer Rodrigues da Silva, Marina Guimarães Roscoe, Otavio Henrique Pinhata-Baptista, Josete Barbosa Cruz Meira, Alex Siu Lun Fok","doi":"10.2186/jpr.JPR_D_24_00003","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to evaluate the risk of bone loss around single short molar crown-supporting implants in an atrophic mandible.</p><p><strong>Methods: </strong>Implants of different lengths (L = 4 or 6 mm) and diameters (Ø = 4.1 or 4.8 mm) were placed in the molar area of an atrophic mandible. Additional control mandible models were simulated for 4.1 mm diameter implants (L = 4, 6, 8, and 10 mm). A vertical masticatory load of 200 N was applied to three or six occlusal contact areas (3ca or 6ca) of the prosthetic crown. The bone strain energy density (SED) of 109.6 µJ/mm<sup>3</sup> was assumed to be the pathological threshold for cortical bone. The peri-implant bone resorption risk index (PIBRri) was calculated by dividing the maximum SED of the crestal cortical bone by the SED pathological threshold.</p><p><strong>Results: </strong>Increasing the implant length from 4 to 6 mm, implant diameter from 4.1 to 4.8 mm, and number of contact areas from 3 to 6 reduced the SED and PIBRri values by approximately 20%, 35%, and 40%, respectively, when comparing pairs of models that isolated a specific variable. All models with 6ca had a low bone resorption risk (PIBRri<0.8), while the Ø4.1 short implant with 3ca had a medium (0.8≤PIBRri≤1.0) or high (PIBRri>1.0) resorption risk.</p><p><strong>Conclusions: </strong>Increasing the diameter or occlusal contact area of a 4 mm short implant in an atrophic mandible resulted in reduced bone resorption risks, similar to or lower than those observed in a regular mandible with standard-length implants.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2186/jpr.JPR_D_24_00003","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: This study aimed to evaluate the risk of bone loss around single short molar crown-supporting implants in an atrophic mandible.
Methods: Implants of different lengths (L = 4 or 6 mm) and diameters (Ø = 4.1 or 4.8 mm) were placed in the molar area of an atrophic mandible. Additional control mandible models were simulated for 4.1 mm diameter implants (L = 4, 6, 8, and 10 mm). A vertical masticatory load of 200 N was applied to three or six occlusal contact areas (3ca or 6ca) of the prosthetic crown. The bone strain energy density (SED) of 109.6 µJ/mm3 was assumed to be the pathological threshold for cortical bone. The peri-implant bone resorption risk index (PIBRri) was calculated by dividing the maximum SED of the crestal cortical bone by the SED pathological threshold.
Results: Increasing the implant length from 4 to 6 mm, implant diameter from 4.1 to 4.8 mm, and number of contact areas from 3 to 6 reduced the SED and PIBRri values by approximately 20%, 35%, and 40%, respectively, when comparing pairs of models that isolated a specific variable. All models with 6ca had a low bone resorption risk (PIBRri<0.8), while the Ø4.1 short implant with 3ca had a medium (0.8≤PIBRri≤1.0) or high (PIBRri>1.0) resorption risk.
Conclusions: Increasing the diameter or occlusal contact area of a 4 mm short implant in an atrophic mandible resulted in reduced bone resorption risks, similar to or lower than those observed in a regular mandible with standard-length implants.