Automated data transfer for digital twin applications: Two case studies.

IF 2.5 4区 环境科学与生态学 Q3 ENGINEERING, ENVIRONMENTAL
Hanna Molin, Christoffer Wärff, Erik Lindblom, Magnus Arnell, Bengt Carlsson, Per Mattsson, Jonas Bäckman, Ulf Jeppsson
{"title":"Automated data transfer for digital twin applications: Two case studies.","authors":"Hanna Molin, Christoffer Wärff, Erik Lindblom, Magnus Arnell, Bengt Carlsson, Per Mattsson, Jonas Bäckman, Ulf Jeppsson","doi":"10.1002/wer.11074","DOIUrl":null,"url":null,"abstract":"<p><p>Digital twins have been gaining an immense interest in various fields over the last decade. Bringing conventional process simulation models into (near) real time are thought to provide valuable insights for operators, decision makers, and stakeholders in many industries. The objective of this paper is to describe two methods for implementing digital twins at water resource recovery facilities and highlight and discuss their differences and preferable use situations, with focus on the automated data transfer from the real process. Case 1 uses a tailor-made infrastructure for automated data transfer between the facility and the digital twin. Case 2 uses edge computing for rapid automated data transfer. The data transfer lag from process to digital twin is low compared to the simulation frequency in both systems. The presented digital twin objectives can be achieved using either of the presented methods. The method of Case 1 is better suited for automatic recalibration of model parameters, although workarounds exist for the method in Case 2. The method of Case 2 is well suited for objectives such as soft sensors due to its integration with the SCADA system and low latency. The objective of the digital twin, and the required latency of the system, should guide the choice of method. PRACTITIONER POINTS: Various methods can be used for automated data transfer between the physical system and a digital twin. Delays in the data transfer differ depending on implementation method. The digital twin objective determines the required simulation frequency. Implementation method should be chosen based on the required simulation frequency.</p>","PeriodicalId":23621,"journal":{"name":"Water Environment Research","volume":"96 7","pages":"e11074"},"PeriodicalIF":2.5000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Water Environment Research","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1002/wer.11074","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Digital twins have been gaining an immense interest in various fields over the last decade. Bringing conventional process simulation models into (near) real time are thought to provide valuable insights for operators, decision makers, and stakeholders in many industries. The objective of this paper is to describe two methods for implementing digital twins at water resource recovery facilities and highlight and discuss their differences and preferable use situations, with focus on the automated data transfer from the real process. Case 1 uses a tailor-made infrastructure for automated data transfer between the facility and the digital twin. Case 2 uses edge computing for rapid automated data transfer. The data transfer lag from process to digital twin is low compared to the simulation frequency in both systems. The presented digital twin objectives can be achieved using either of the presented methods. The method of Case 1 is better suited for automatic recalibration of model parameters, although workarounds exist for the method in Case 2. The method of Case 2 is well suited for objectives such as soft sensors due to its integration with the SCADA system and low latency. The objective of the digital twin, and the required latency of the system, should guide the choice of method. PRACTITIONER POINTS: Various methods can be used for automated data transfer between the physical system and a digital twin. Delays in the data transfer differ depending on implementation method. The digital twin objective determines the required simulation frequency. Implementation method should be chosen based on the required simulation frequency.

数字孪生应用的自动数据传输:两个案例研究。
过去十年来,数字孪生在各个领域都获得了极大的关注。人们认为,将传统工艺模拟模型带入(接近)实时状态可为许多行业的操作人员、决策者和利益相关者提供有价值的见解。本文旨在介绍在水资源回收设施中实施数字孪生的两种方法,并着重讨论它们之间的差异和可取的使用情况,重点是实际流程中的自动数据传输。案例 1 使用定制的基础设施在设施和数字孪生之间进行自动数据传输。案例 2 使用边缘计算实现快速自动数据传输。与两个系统的模拟频率相比,从流程到数字孪生的数据传输滞后较低。上述两种方法中的任何一种都能实现数字孪生的目标。情况 1 的方法更适合模型参数的自动重新校准,尽管情况 2 的方法存在变通方法。情况 2 的方法与 SCADA 系统集成,延迟时间短,非常适合软传感器等目标。数字孪生系统的目标和系统所需的延迟时间应指导方法的选择。实践点:物理系统与数字孪生系统之间的自动数据传输可采用多种方法。实施方法不同,数据传输的延迟时间也不同。数字孪生目标决定了所需的模拟频率。应根据所需的模拟频率选择实施方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Water Environment Research
Water Environment Research 环境科学-工程:环境
CiteScore
6.30
自引率
0.00%
发文量
138
审稿时长
11 months
期刊介绍: Published since 1928, Water Environment Research (WER) is an international multidisciplinary water resource management journal for the dissemination of fundamental and applied research in all scientific and technical areas related to water quality and resource recovery. WER''s goal is to foster communication and interdisciplinary research between water sciences and related fields such as environmental toxicology, agriculture, public and occupational health, microbiology, and ecology. In addition to original research articles, short communications, case studies, reviews, and perspectives are encouraged.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信