André Luiz de Melo Moreno, Marcio Campaner, Clóvis Lamartine de Moraes Melo Neto, Nathaly Vilene de Araújo Moreno, Daniela Micheline Dos Santos, Marcelo Coelho Goiato
{"title":"Evaluation of Microstrain in the Regions Surrounding Morse Taper and External Hexagon Implants.","authors":"André Luiz de Melo Moreno, Marcio Campaner, Clóvis Lamartine de Moraes Melo Neto, Nathaly Vilene de Araújo Moreno, Daniela Micheline Dos Santos, Marcelo Coelho Goiato","doi":"10.1055/s-0044-1787696","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong> The aim of this study was to compare the Morse taper (MT) + titanium base (Ti-Base) abutment with the external hexagon (EH) + Ti-Base abutment by using the strain gauge method in the mesial, distal, and apical-buccal areas around these types of implants.</p><p><strong>Materials and methods: </strong> This study investigated two groups, MT and EH, each comprising five polyurethane samples with a dental implant in the area of artificial tooth 15 (3.75 × 11.5 mm) of a dental manikin. The strain gauges were glued to the mesial, distal, and apical-buccal polyurethane areas of all samples in relation to the implant. Ti-Base nonangled abutments measuring 5.0 × 4.7 × 1.0 mm (DSP, Brazil) were installed on the implants in each group. Ten identical zirconia crowns were constructed by scanning and milling and were subsequently cemented onto the Ti-base abutments with calcium hydroxide cement. Then, an axial load of 100 N was applied to the occlusal region of the zirconia crowns, and strain gauge measurements were taken.</p><p><strong>Statistical analysis: </strong> Strain gauge data were assessed by a two-way analysis of variance (ANOVA) with \"implant connection\" and \"strain gauge position\" factors, followed by the Bonferroni test (<i>p</i> < 0.05).</p><p><strong>Results: </strong> The MT group exhibited a statistically significant reduction in microstrain in the mesial and apical strain gauge measurements compared to the EH group.</p><p><strong>Conclusion: </strong> The MT group exhibited less microstrain in the mesial and apical areas of the polyurethane samples near the implant. Consequently, the MT connection was considered more biomechanically advantageous.</p>","PeriodicalId":12028,"journal":{"name":"European Journal of Dentistry","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0044-1787696","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: The aim of this study was to compare the Morse taper (MT) + titanium base (Ti-Base) abutment with the external hexagon (EH) + Ti-Base abutment by using the strain gauge method in the mesial, distal, and apical-buccal areas around these types of implants.
Materials and methods: This study investigated two groups, MT and EH, each comprising five polyurethane samples with a dental implant in the area of artificial tooth 15 (3.75 × 11.5 mm) of a dental manikin. The strain gauges were glued to the mesial, distal, and apical-buccal polyurethane areas of all samples in relation to the implant. Ti-Base nonangled abutments measuring 5.0 × 4.7 × 1.0 mm (DSP, Brazil) were installed on the implants in each group. Ten identical zirconia crowns were constructed by scanning and milling and were subsequently cemented onto the Ti-base abutments with calcium hydroxide cement. Then, an axial load of 100 N was applied to the occlusal region of the zirconia crowns, and strain gauge measurements were taken.
Statistical analysis: Strain gauge data were assessed by a two-way analysis of variance (ANOVA) with "implant connection" and "strain gauge position" factors, followed by the Bonferroni test (p < 0.05).
Results: The MT group exhibited a statistically significant reduction in microstrain in the mesial and apical strain gauge measurements compared to the EH group.
Conclusion: The MT group exhibited less microstrain in the mesial and apical areas of the polyurethane samples near the implant. Consequently, the MT connection was considered more biomechanically advantageous.
期刊介绍:
The European Journal of Dentistry is the official journal of the Dental Investigations Society, based in Turkey. It is a double-blinded peer-reviewed, Open Access, multi-disciplinary international journal addressing various aspects of dentistry. The journal''s board consists of eminent investigators in dentistry from across the globe and presents an ideal international composition. The journal encourages its authors to submit original investigations, reviews, and reports addressing various divisions of dentistry including oral pathology, prosthodontics, endodontics, orthodontics etc. It is available both online and in print.