A case of truncus arteriosus with severe heart failure and pulmonary stenosis: bridge to transplant candidacy with surgical correction and a ventricular-assist device.

IF 1.1 4区 医学 Q4 ENGINEERING, BIOMEDICAL
Kazuki Tanimoto, Takashi Kido, Masaki Taira, Takuji Watanabe, Jun Narita, Hidekazu Ishida, Ryo Ishii, Takayoshi Ueno, Shigeru Miyagawa
{"title":"A case of truncus arteriosus with severe heart failure and pulmonary stenosis: bridge to transplant candidacy with surgical correction and a ventricular-assist device.","authors":"Kazuki Tanimoto, Takashi Kido, Masaki Taira, Takuji Watanabe, Jun Narita, Hidekazu Ishida, Ryo Ishii, Takayoshi Ueno, Shigeru Miyagawa","doi":"10.1007/s10047-024-01456-w","DOIUrl":null,"url":null,"abstract":"<p><p>Ventricular-assist device therapy for small patients with congenital heart disease is challenging due to its complex anatomy and hemodynamics. We describe a 3-year-old patient with heart failure with truncus arteriosus in the palliative stage. The patient underwent palliative right ventricular outflow tract reconstruction following bilateral pulmonary artery banding. At 6 months of age, the patient developed severe truncal valve regurgitation and left ventricular dysfunction. Emergent truncal valve replacement with a mechanical valve was performed, but left ventricular dysfunction persisted. At 3 years of age, the patient developed acute progression of heart failure triggered by influenza infection. The patient was intubated and transferred to our center to determine the indication for heart transplantation. On the second day after admission, signs of multiorgan failure appeared. Emergent ventricular-assist device implantation for both ventricles was performed with truncal valve closure, ventricular septal defect closure, atrial septal defect closure, and re-right ventricular outflow tract reconstruction. The right ventricular-assist device was successfully removed on the seventh postoperative day. Due to the small pulmonary arteries, severe pulmonary stenosis persisted after ventricular-assist device implantation, but it gradually improved with multiple pulmonary angioplasties. The patient was registered in the Japanese organ transplant network and is awaiting a donor organ in a stable condition.</p>","PeriodicalId":15177,"journal":{"name":"Journal of Artificial Organs","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10047-024-01456-w","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Ventricular-assist device therapy for small patients with congenital heart disease is challenging due to its complex anatomy and hemodynamics. We describe a 3-year-old patient with heart failure with truncus arteriosus in the palliative stage. The patient underwent palliative right ventricular outflow tract reconstruction following bilateral pulmonary artery banding. At 6 months of age, the patient developed severe truncal valve regurgitation and left ventricular dysfunction. Emergent truncal valve replacement with a mechanical valve was performed, but left ventricular dysfunction persisted. At 3 years of age, the patient developed acute progression of heart failure triggered by influenza infection. The patient was intubated and transferred to our center to determine the indication for heart transplantation. On the second day after admission, signs of multiorgan failure appeared. Emergent ventricular-assist device implantation for both ventricles was performed with truncal valve closure, ventricular septal defect closure, atrial septal defect closure, and re-right ventricular outflow tract reconstruction. The right ventricular-assist device was successfully removed on the seventh postoperative day. Due to the small pulmonary arteries, severe pulmonary stenosis persisted after ventricular-assist device implantation, but it gradually improved with multiple pulmonary angioplasties. The patient was registered in the Japanese organ transplant network and is awaiting a donor organ in a stable condition.

Abstract Image

一例动脉导管未闭并伴有严重心衰和肺动脉狭窄的病例:通过手术矫正和心室辅助装置为移植候选者搭建桥梁。
由于先天性心脏病患者的解剖结构和血流动力学非常复杂,因此对体型较小的患者进行心室辅助装置治疗具有挑战性。我们描述了一名 3 岁心力衰竭伴动脉导管未闭患者的姑息治疗情况。患者在接受双侧肺动脉束扎术后,接受了姑息性右室流出道重建术。6 个月大时,患者出现严重的截流瓣反流和左心室功能障碍。医生紧急用机械瓣膜进行了截流瓣置换术,但左心室功能障碍依然存在。3 岁时,患者因感染流感引发急性心力衰竭。患者被插管并转入本中心,以确定心脏移植的适应症。入院后第二天,出现了多器官衰竭的迹象。我们紧急为患者的两个心室植入了心室辅助装置,同时进行了截流瓣关闭术、室间隔缺损关闭术、房间隔缺损关闭术和右心室流出道重建术。术后第七天,成功取出了右室辅助装置。由于肺动脉较小,植入心室辅助装置后仍存在严重的肺动脉狭窄,但经过多次肺血管成形术后,情况逐渐好转。患者已在日本器官移植网络注册,目前正在等待供体器官,病情稳定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Artificial Organs
Journal of Artificial Organs 医学-工程:生物医学
CiteScore
2.80
自引率
15.40%
发文量
68
审稿时长
6-12 weeks
期刊介绍: The aim of the Journal of Artificial Organs is to introduce to colleagues worldwide a broad spectrum of important new achievements in the field of artificial organs, ranging from fundamental research to clinical applications. The scope of the Journal of Artificial Organs encompasses but is not restricted to blood purification, cardiovascular intervention, biomaterials, and artificial metabolic organs. Additionally, the journal will cover technical and industrial innovations. Membership in the Japanese Society for Artificial Organs is not a prerequisite for submission.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信