Improved high-performance liquid chromatography tandem mass spectrometry method for quantification of infliximab in pediatric plasma and its application in therapeutic drug monitoring
{"title":"Improved high-performance liquid chromatography tandem mass spectrometry method for quantification of infliximab in pediatric plasma and its application in therapeutic drug monitoring","authors":"Boran Yu, Siyao Jin, Jiaqi Han, Xiaona Li, Jiamin Xu, Ning Sun, Liang Sun, Xiaoling Wang, Libo Zhao","doi":"10.1002/rcm.9865","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Rationale</h3>\n \n <p>The application of infliximab (IFX) to immune-mediated disease is limited by the significant individual variability and associated clinical nonresponse, emphasizing the importance of therapeutic drug monitoring (TDM). Because of the cross-reactivity, limited linear range, and high costs, the clinical application of the previous reported methods was limited. Here, an improved high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method was developed to address the issues.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>This study developed an improved bioanalytical HPLC-MS/MS method coupling nanosurface and molecular-orientation limited proteolysis technology. The commercially available compound P14R was selected as the internal standard. This method was developed with fewer volume of reagents and was thoroughly validated. The validated method was applied to TDM in pediatric inflammatory bowel disease (IBD).</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Chromatography was performed using a Shim-pack GISS-HP C<sub>18</sub> metal-free column (3 μm, 2.1 × 100 mm) with a gradient elution of 0.1% formic acid in water and acetonitrile at 0.4 mL/min. Detection and quantitation were performed using electrospray ionization (ESI) and multiple reaction monitoring in the positive ion mode. The method was validated to demonstrate its selectivity, linearity, accuracy, precision, recovery, matrix effect, and stability. The method exhibited a linear dynamic range of 0.3–100 μg/mL, with intra- and inter-day precision and relative errors below 15%. The recovery and matrix effect were measured as 87.28%–89.72% and 41.98%–67.17%, respectively, which were effectively compensated by the internal standard. A total of 32 samples collected from 24 pediatric patients with IBD were analyzed using the validated method, and only 46.9% achieved the reported targeted trough level.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>This study developed an improved HPLC-MS/MS method for the quantitative determination of IFX concentration in human plasma. The accurate, reliable, and cost-effective method was validated and utilized in the analysis of clinical samples. The results confirmed the importance of TDM on IFX and the clinical application prospects of the improved method.</p>\n </section>\n </div>","PeriodicalId":225,"journal":{"name":"Rapid Communications in Mass Spectrometry","volume":"38 18","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rapid Communications in Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/rcm.9865","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
Rationale
The application of infliximab (IFX) to immune-mediated disease is limited by the significant individual variability and associated clinical nonresponse, emphasizing the importance of therapeutic drug monitoring (TDM). Because of the cross-reactivity, limited linear range, and high costs, the clinical application of the previous reported methods was limited. Here, an improved high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method was developed to address the issues.
Methods
This study developed an improved bioanalytical HPLC-MS/MS method coupling nanosurface and molecular-orientation limited proteolysis technology. The commercially available compound P14R was selected as the internal standard. This method was developed with fewer volume of reagents and was thoroughly validated. The validated method was applied to TDM in pediatric inflammatory bowel disease (IBD).
Results
Chromatography was performed using a Shim-pack GISS-HP C18 metal-free column (3 μm, 2.1 × 100 mm) with a gradient elution of 0.1% formic acid in water and acetonitrile at 0.4 mL/min. Detection and quantitation were performed using electrospray ionization (ESI) and multiple reaction monitoring in the positive ion mode. The method was validated to demonstrate its selectivity, linearity, accuracy, precision, recovery, matrix effect, and stability. The method exhibited a linear dynamic range of 0.3–100 μg/mL, with intra- and inter-day precision and relative errors below 15%. The recovery and matrix effect were measured as 87.28%–89.72% and 41.98%–67.17%, respectively, which were effectively compensated by the internal standard. A total of 32 samples collected from 24 pediatric patients with IBD were analyzed using the validated method, and only 46.9% achieved the reported targeted trough level.
Conclusion
This study developed an improved HPLC-MS/MS method for the quantitative determination of IFX concentration in human plasma. The accurate, reliable, and cost-effective method was validated and utilized in the analysis of clinical samples. The results confirmed the importance of TDM on IFX and the clinical application prospects of the improved method.
期刊介绍:
Rapid Communications in Mass Spectrometry is a journal whose aim is the rapid publication of original research results and ideas on all aspects of the science of gas-phase ions; it covers all the associated scientific disciplines. There is no formal limit on paper length ("rapid" is not synonymous with "brief"), but papers should be of a length that is commensurate with the importance and complexity of the results being reported. Contributions may be theoretical or practical in nature; they may deal with methods, techniques and applications, or with the interpretation of results; they may cover any area in science that depends directly on measurements made upon gaseous ions or that is associated with such measurements.