{"title":"Emission Factor Estimation Using Monte Carlo Simulation: Focusing on the Development of Dioxin Emission Factors in Cremation Facilities","authors":"Mi Hyeon Lee, Young-Kwon Park","doi":"10.1007/s11814-024-00211-4","DOIUrl":null,"url":null,"abstract":"<div><p>In this study, data from 23 domestic cremation facilities measured for 5 years (from 2016 to 2020) of 13 domestic cremation facilities was used to calculate the emission factors of dioxins (PCDD/DFs) of cremation facilities that use Liquified Natural Gas (LNG) as combustion fuel. We performed a statistical analysis for the first time to estimate the emission factor using limited measurement results from cremation facilities that are not easily accessible. We attempted to identify the emission concentration of dioxin as a representative persistent organic pollutants substance and developed a statistically based dioxin emission factor. The concentration of dioxins (PCDD/DFs) in the cremation facility ranged 0.001–4.440 ng I-TEQ/Sm<sup>3</sup> with an average concentration of 0.719 ng I-TEQ/Sm<sup>3</sup>. The emission factor calculated using the 23 measured data showed 0.010–21.485 μg I-TEQ/Cremation. A Monte Carlo Simulation was conducted using probability density distribution and parameter estimation. Consequently, 10,000 emission factors were selected, and the Pareto distribution was predicted to be the most appropriate probability density distribution. The emission factor values through Monte Carlo simulation showed a minimum value of 1.490 × 10–08 μg I-TEQ/Cremation and a maximum value of 7816 μg I-TEQ/Cremation. The average value was calculated as 39.920 μg I-TEQ/Cremation. Each parameter of the Pareto distribution is shape parameter (<i>α</i>) 1.026, location parameter (<i>μ</i>) – 1.021, and scale parameter (<i>λ</i>) 1.021. As a result of this study, the median value of the cumulative density function was selected as a representative value for the dioxin emission factor of cremation facilities and the emission factor was 0.986 μg I-TEQ/ Cremation. The 95% confidence interval in the Pareto distribution was presented as 0.026 μg I-TEQ/Cremation to 36.216 μg I-TEQ/ Cremation.</p></div>","PeriodicalId":684,"journal":{"name":"Korean Journal of Chemical Engineering","volume":"41 9","pages":"2607 - 2619"},"PeriodicalIF":2.9000,"publicationDate":"2024-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Chemical Engineering","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s11814-024-00211-4","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
In this study, data from 23 domestic cremation facilities measured for 5 years (from 2016 to 2020) of 13 domestic cremation facilities was used to calculate the emission factors of dioxins (PCDD/DFs) of cremation facilities that use Liquified Natural Gas (LNG) as combustion fuel. We performed a statistical analysis for the first time to estimate the emission factor using limited measurement results from cremation facilities that are not easily accessible. We attempted to identify the emission concentration of dioxin as a representative persistent organic pollutants substance and developed a statistically based dioxin emission factor. The concentration of dioxins (PCDD/DFs) in the cremation facility ranged 0.001–4.440 ng I-TEQ/Sm3 with an average concentration of 0.719 ng I-TEQ/Sm3. The emission factor calculated using the 23 measured data showed 0.010–21.485 μg I-TEQ/Cremation. A Monte Carlo Simulation was conducted using probability density distribution and parameter estimation. Consequently, 10,000 emission factors were selected, and the Pareto distribution was predicted to be the most appropriate probability density distribution. The emission factor values through Monte Carlo simulation showed a minimum value of 1.490 × 10–08 μg I-TEQ/Cremation and a maximum value of 7816 μg I-TEQ/Cremation. The average value was calculated as 39.920 μg I-TEQ/Cremation. Each parameter of the Pareto distribution is shape parameter (α) 1.026, location parameter (μ) – 1.021, and scale parameter (λ) 1.021. As a result of this study, the median value of the cumulative density function was selected as a representative value for the dioxin emission factor of cremation facilities and the emission factor was 0.986 μg I-TEQ/ Cremation. The 95% confidence interval in the Pareto distribution was presented as 0.026 μg I-TEQ/Cremation to 36.216 μg I-TEQ/ Cremation.
期刊介绍:
The Korean Journal of Chemical Engineering provides a global forum for the dissemination of research in chemical engineering. The Journal publishes significant research results obtained in the Asia-Pacific region, and simultaneously introduces recent technical progress made in other areas of the world to this region. Submitted research papers must be of potential industrial significance and specifically concerned with chemical engineering. The editors will give preference to papers having a clearly stated practical scope and applicability in the areas of chemical engineering, and to those where new theoretical concepts are supported by new experimental details. The Journal also regularly publishes featured reviews on emerging and industrially important subjects of chemical engineering as well as selected papers presented at international conferences on the subjects.