Comparative Analysis of Endoscope Obscuration With Utilization of an Endonasal Access Guide for Endonasal Skull Base Surgery.

IF 1.7 4区 医学 Q3 CLINICAL NEUROLOGY
Operative Neurosurgery Pub Date : 2025-02-01 Epub Date: 2024-07-05 DOI:10.1227/ons.0000000000001267
Garni Barkhoudarian, David Zhou, Michael B Avery, Usman Khan, Regin Jay Mallari, Josh Emerson, Chester Griffiths, Daniel F Kelly
{"title":"Comparative Analysis of Endoscope Obscuration With Utilization of an Endonasal Access Guide for Endonasal Skull Base Surgery.","authors":"Garni Barkhoudarian, David Zhou, Michael B Avery, Usman Khan, Regin Jay Mallari, Josh Emerson, Chester Griffiths, Daniel F Kelly","doi":"10.1227/ons.0000000000001267","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong>In endoscopic endonasal approaches (EEAs) for skull base pathologies, endoscope view obscuration remains a persistent, time-consuming, and distracting issue for surgeons and may result in increased operative time. The endonasal access guide (EAG) has been demonstrated as a possible adjunct to minimize these events. However, to date, there have been no comparative studies performed and the potential time savings by using EAGs have yet to be quantified. This cohort study aimed to determine the operative efficiency benefits of the EAG in EEA operations.</p><p><strong>Methods: </strong>Analysis of EEA operative videos from an EAG cohort (n = 20) and a control cohort (n = 20) was performed, assessing 12-minute segments in the first, middle, and last third of each operation. The first segment in each cohort was selected before EAG placement, serving as an internal control. Every endoscope lens soiling instance was counted (measured as cleaning actions per minute), timed (obscuration time %), and identified as a withdrawal, irrigation, or other cleaning action. Perioperative variables including skull base repair and postoperative cerebrospinal fluid leakage were assessed.</p><p><strong>Results: </strong>Within the EAG cohort, obscuration time was reduced in the middle and last third compared with the first third (3.73% [CI: 2.39-5.07] vs 12.97% [CI: 10.24-15.70], P < .001; 4.19% [CI: 2.83-5.55] vs 12.97% [CI: 10.24-15.70], P < .001) and cleaning actions were also significantly reduced by EAG (0.69/min [CI: 0.39-0.99] vs 1.67/min [CI: 1.34-2.00], P = .001; 0.66/min [CI: 0.35-0.97] vs 1.67/min [CI: 1.34-2.00], P < .001). Between the control and EAG cohorts, there was no significant difference between obscuration time and cleaning actions in the first third (9.33% vs 12.97%, P = .086; 1.34/min vs 1.67/min, P = .151) or in the middle third (6.24% vs 3.73%, P = .140; 0.80/min vs 0.69/min, P = .335), but there was a significant difference in the last third (9.25% [CI: 6.95-11.55] vs 4.19% [CI: 2.83-5.55], P < .001; 0.95/min [CI: 0.73-1.17] vs 0.66/min [CI: 0.35-0.97], P = .018).</p><p><strong>Conclusion: </strong>EAG significantly reduces lens obscurations and cleaning events, particularly during the intradural portion of operations. This technology may offer a greater time-saving impact with patients undergoing long EEA operations.</p>","PeriodicalId":54254,"journal":{"name":"Operative Neurosurgery","volume":" ","pages":"203-209"},"PeriodicalIF":1.7000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Operative Neurosurgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1227/ons.0000000000001267","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/5 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and objectives: In endoscopic endonasal approaches (EEAs) for skull base pathologies, endoscope view obscuration remains a persistent, time-consuming, and distracting issue for surgeons and may result in increased operative time. The endonasal access guide (EAG) has been demonstrated as a possible adjunct to minimize these events. However, to date, there have been no comparative studies performed and the potential time savings by using EAGs have yet to be quantified. This cohort study aimed to determine the operative efficiency benefits of the EAG in EEA operations.

Methods: Analysis of EEA operative videos from an EAG cohort (n = 20) and a control cohort (n = 20) was performed, assessing 12-minute segments in the first, middle, and last third of each operation. The first segment in each cohort was selected before EAG placement, serving as an internal control. Every endoscope lens soiling instance was counted (measured as cleaning actions per minute), timed (obscuration time %), and identified as a withdrawal, irrigation, or other cleaning action. Perioperative variables including skull base repair and postoperative cerebrospinal fluid leakage were assessed.

Results: Within the EAG cohort, obscuration time was reduced in the middle and last third compared with the first third (3.73% [CI: 2.39-5.07] vs 12.97% [CI: 10.24-15.70], P < .001; 4.19% [CI: 2.83-5.55] vs 12.97% [CI: 10.24-15.70], P < .001) and cleaning actions were also significantly reduced by EAG (0.69/min [CI: 0.39-0.99] vs 1.67/min [CI: 1.34-2.00], P = .001; 0.66/min [CI: 0.35-0.97] vs 1.67/min [CI: 1.34-2.00], P < .001). Between the control and EAG cohorts, there was no significant difference between obscuration time and cleaning actions in the first third (9.33% vs 12.97%, P = .086; 1.34/min vs 1.67/min, P = .151) or in the middle third (6.24% vs 3.73%, P = .140; 0.80/min vs 0.69/min, P = .335), but there was a significant difference in the last third (9.25% [CI: 6.95-11.55] vs 4.19% [CI: 2.83-5.55], P < .001; 0.95/min [CI: 0.73-1.17] vs 0.66/min [CI: 0.35-0.97], P = .018).

Conclusion: EAG significantly reduces lens obscurations and cleaning events, particularly during the intradural portion of operations. This technology may offer a greater time-saving impact with patients undergoing long EEA operations.

颅底内窥镜手术中使用内窥镜入路导向器时内窥镜遮挡情况的对比分析
背景和目的:在内窥镜颅内入路(EEA)治疗颅底病变的过程中,内窥镜视线模糊仍然是一个持续存在、耗时且分散外科医生注意力的问题,并可能导致手术时间延长。内窥镜入路引导器(EAG)已被证明是一种可能的辅助工具,可最大限度地减少此类事件的发生。然而,迄今为止还没有进行过比较研究,使用 EAG 可能节省的时间也尚未量化。这项队列研究旨在确定 EAG 在 EEA 手术中的手术效率优势:对来自 EAG 队列(n = 20)和对照队列(n = 20)的 EEA 手术视频进行分析,评估每个手术的前三分之一、中间三分之一和最后三分之一的 12 分钟片段。每个队列中的第一个片段都是在放置 EAG 之前选取的,作为内部对照。对每个内窥镜镜头弄脏的情况进行计数(以每分钟的清洁动作来衡量)、计时(模糊时间%),并确定是抽出、冲洗还是其他清洁动作。对包括颅底修复和术后脑脊液漏在内的围手术期变量进行了评估:结果:在 EAG 队列中,与前三分之一相比,中间和后三分之一的模糊时间缩短(3.73% [CI: 2.39-5.07] vs 12.97% [CI: 10.24-15.70], P < .001;4.19% [CI: 2.83-5.55] vs 12.97% [CI: 10.24-15.70],P < .001),清洁动作也因 EAG 而显著减少(0.69/分钟 [CI: 0.39-0.99] vs 1.67/min [CI: 1.34-2.00],P = .001;0.66/分钟 [CI: 0.35-0.97] vs 1.67/min [CI: 1.34-2.00],P < .001)。在对照组和 EAG 组之间,前三分之一(9.33% vs 12.97%,P = .086;1.34/min vs 1.67/min,P = .151)或中间三分之一(6.24% vs 3. 73%,P = .140;1.34/min vs 1.67/min,P = .151)的遮盖时间和清洁动作之间没有显著差异。73%,P = .140;0.80/min vs 0.69/min,P = .335),但最后三分之一有显著差异(9.25% [CI: 6.95-11.55] vs 4.19% [CI: 2.83-5.55], P < .001;0.95/min [CI: 0.73-1.17] vs 0.66/min [CI: 0.35-0.97], P = .018):结论:EAG 能明显减少晶状体混浊和清洁事件,尤其是在硬膜外手术中。结论:EAG 可明显减少晶状体模糊和清洁事件,尤其是在手术的椎管内部分。这项技术可为进行长时间 EEA 手术的患者节省更多时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Operative Neurosurgery
Operative Neurosurgery Medicine-Neurology (clinical)
CiteScore
3.10
自引率
13.00%
发文量
530
期刊介绍: Operative Neurosurgery is a bi-monthly, unique publication focusing exclusively on surgical technique and devices, providing practical, skill-enhancing guidance to its readers. Complementing the clinical and research studies published in Neurosurgery, Operative Neurosurgery brings the reader technical material that highlights operative procedures, anatomy, instrumentation, devices, and technology. Operative Neurosurgery is the practical resource for cutting-edge material that brings the surgeon the most up to date literature on operative practice and technique
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信