Inclinometer use in primary total hip arthroplasty does not improve acetabular component positioning: a non-randomized control trial.

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS
Kyle Goldstein, Wyatt Tyndall, Michaela E Nickol, Johannes M van der Merwe
{"title":"Inclinometer use in primary total hip arthroplasty does not improve acetabular component positioning: a non-randomized control trial.","authors":"Kyle Goldstein, Wyatt Tyndall, Michaela E Nickol, Johannes M van der Merwe","doi":"10.1186/s42836-024-00258-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Total hip arthroplasty (THA) is a common surgical procedure that aims to relieve pain, improve function, and increase mobility in patients with hip joint pathology. One of the most challenging aspects of THA is to determine the correct angle of the acetabular component's placement. Intraoperative inclinometers have emerged as a promising tool to obtain accurate measurements of the acetabular component's inclination. The primary objective of this study was to evaluate the accuracy and efficacy of using intraoperative inclinometers for THA.</p><p><strong>Methods: </strong>This non-randomized control trial evaluated patients undergoing primary THA. Patients in the inclinometer group had an inclinometer used intraoperatively to measure acetabular component inclination, and patients in the control group had no inclinometer. Inclination and anteversion of the acetabular component were measured on postoperative radiographs.</p><p><strong>Results: </strong>A total of 223 patients were included in the study. The mean inclination angle of the acetabular cup was significantly higher in the inclinometer group (43.9° vs. 41.5°, P < 0.001). This difference was not clinically significant. There was no significant difference in anteversion. There were no significant differences in the number of patients within the safe zones for inclination or anteversion, or in the number of patients experiencing a dislocation. No correlation was found between inclinometer measurement and measured acetabular component inclination. Inclinometer use and body mass index (BMI) were the sole statistically significant factors in determining acetabular component inclination.</p><p><strong>Conclusions: </strong>This study indicated no current benefit to inclinometer use during primary THA, as measured by inclination, anteversion, and dislocation rate. However, this might be confounded by subtle variations in patient positioning, which may be a strong area of study in the future.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11229020/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s42836-024-00258-y","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Total hip arthroplasty (THA) is a common surgical procedure that aims to relieve pain, improve function, and increase mobility in patients with hip joint pathology. One of the most challenging aspects of THA is to determine the correct angle of the acetabular component's placement. Intraoperative inclinometers have emerged as a promising tool to obtain accurate measurements of the acetabular component's inclination. The primary objective of this study was to evaluate the accuracy and efficacy of using intraoperative inclinometers for THA.

Methods: This non-randomized control trial evaluated patients undergoing primary THA. Patients in the inclinometer group had an inclinometer used intraoperatively to measure acetabular component inclination, and patients in the control group had no inclinometer. Inclination and anteversion of the acetabular component were measured on postoperative radiographs.

Results: A total of 223 patients were included in the study. The mean inclination angle of the acetabular cup was significantly higher in the inclinometer group (43.9° vs. 41.5°, P < 0.001). This difference was not clinically significant. There was no significant difference in anteversion. There were no significant differences in the number of patients within the safe zones for inclination or anteversion, or in the number of patients experiencing a dislocation. No correlation was found between inclinometer measurement and measured acetabular component inclination. Inclinometer use and body mass index (BMI) were the sole statistically significant factors in determining acetabular component inclination.

Conclusions: This study indicated no current benefit to inclinometer use during primary THA, as measured by inclination, anteversion, and dislocation rate. However, this might be confounded by subtle variations in patient positioning, which may be a strong area of study in the future.

在初次全髋关节置换术中使用倾斜仪并不能改善髋臼组件的定位:一项非随机对照试验。
简介:全髋关节置换术(THA)是一种常见的外科手术,旨在减轻髋关节病变患者的疼痛、改善功能并增加活动度。全髋关节置换术最具挑战性的一点是确定髋臼组件的正确放置角度。术中倾角仪是一种很有前途的工具,可用于准确测量髋臼组件的倾角。本研究的主要目的是评估在 THA 中使用术中倾角仪的准确性和有效性:这项非随机对照试验对接受初级 THA 的患者进行了评估。倾角仪组患者术中使用倾角仪测量髋臼组件倾角,对照组患者不使用倾角仪。术后拍片时测量髋臼组件的倾斜度和前倾角:共有 223 名患者参与了研究。倾角仪组的髋臼杯平均倾角明显更高(43.9° vs. 41.5°,P 结论:该研究表明,使用倾角仪目前没有任何益处:这项研究表明,从倾斜度、前倾角和脱位率来看,在初次 THA 中使用倾角仪目前没有任何益处。不过,这可能受到患者体位微妙变化的影响,这可能是未来研究的一个重点领域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信