Grant D Senyei, Ala Eddin S Sagar, Brian Tran, Archan Shah, Russell Miller, Niral Patel, Keriann Van Nostrand, Roberto F Casal, George Z Cheng
{"title":"Incremental Application of Positive End-Expiratory Pressure for the Evaluation of Atelectasis During RP-EBUS and Bronchoscopy (I-APPEAR).","authors":"Grant D Senyei, Ala Eddin S Sagar, Brian Tran, Archan Shah, Russell Miller, Niral Patel, Keriann Van Nostrand, Roberto F Casal, George Z Cheng","doi":"10.1097/LBR.0000000000000969","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>CT-to-body divergence-described as the difference between preprocedural CT scans and intraprocedural lung architecture-is a significant barrier to improving diagnostic yield during navigational bronchoscopy. A major proposed contributor to CT-to-body divergence is the development of atelectasis, which can confound visualization of peripheral lung lesions via radial probe endobronchial ultrasound (RP-EBUS). High positive end-expiratory pressure (PEEP) ventilatory strategies have been used to decrease atelectasis, allowing the lesion to re-APPEAR on intraprocedure imaging. However, standardized PEEP levels may not be appropriate for all patients due to hemodynamic and ventilatory impacts.</p><p><strong>Methods: </strong>We performed a multicenter, prospective observational study in which patients were imaged with RP-EBUS under general anesthesia to determine if subsegmental atelectasis would resolve as incremental increases in PEEP were applied. Resolution of atelectasis was based on the transition from a non-aerated pattern to an aerated appearance on RP-EBUS. RP-EBUS images were reviewed by 3 experienced operators to determine correlation.</p><p><strong>Results: </strong>Forty-three patients underwent RP-EBUS examination following navigational bronchoscopy. Thirty-seven patients underwent incremental PEEP application and subsequent RP-EBUS imaging. Atelectasis was determined to have resolved in 33 patients (88.2%) following increased PEEP. The intraclass correlation coefficient between reviewers was 0.76. A recruitment maneuver was performed in 7 (16.3%) patients after atelectasis persisted at maximal PEEP. Atelectasis was not identified in the examined subsegments in 6 (10.8%) patients despite zero PEEP.</p><p><strong>Conclusion: </strong>RP-EBUS is an effective tool to monitor what pressure atelectasis within a lung segment has resolved with increasing levels of PEEP.</p>","PeriodicalId":15268,"journal":{"name":"Journal of Bronchology & Interventional Pulmonology","volume":null,"pages":null},"PeriodicalIF":3.3000,"publicationDate":"2024-06-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Bronchology & Interventional Pulmonology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/LBR.0000000000000969","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0
Abstract
Background: CT-to-body divergence-described as the difference between preprocedural CT scans and intraprocedural lung architecture-is a significant barrier to improving diagnostic yield during navigational bronchoscopy. A major proposed contributor to CT-to-body divergence is the development of atelectasis, which can confound visualization of peripheral lung lesions via radial probe endobronchial ultrasound (RP-EBUS). High positive end-expiratory pressure (PEEP) ventilatory strategies have been used to decrease atelectasis, allowing the lesion to re-APPEAR on intraprocedure imaging. However, standardized PEEP levels may not be appropriate for all patients due to hemodynamic and ventilatory impacts.
Methods: We performed a multicenter, prospective observational study in which patients were imaged with RP-EBUS under general anesthesia to determine if subsegmental atelectasis would resolve as incremental increases in PEEP were applied. Resolution of atelectasis was based on the transition from a non-aerated pattern to an aerated appearance on RP-EBUS. RP-EBUS images were reviewed by 3 experienced operators to determine correlation.
Results: Forty-three patients underwent RP-EBUS examination following navigational bronchoscopy. Thirty-seven patients underwent incremental PEEP application and subsequent RP-EBUS imaging. Atelectasis was determined to have resolved in 33 patients (88.2%) following increased PEEP. The intraclass correlation coefficient between reviewers was 0.76. A recruitment maneuver was performed in 7 (16.3%) patients after atelectasis persisted at maximal PEEP. Atelectasis was not identified in the examined subsegments in 6 (10.8%) patients despite zero PEEP.
Conclusion: RP-EBUS is an effective tool to monitor what pressure atelectasis within a lung segment has resolved with increasing levels of PEEP.