Erosion and intergranular corrosion induced failure of S31254 stainless steel – Case study on Venturi scrubber in a natural gas purification plant

IF 3.6 3区 工程技术 Q2 ENGINEERING, CHEMICAL
Ganghua Huang , Jingjing Jiang , Rui Fan , Chao Miao , Yongfan Tang , Shuang Yang
{"title":"Erosion and intergranular corrosion induced failure of S31254 stainless steel – Case study on Venturi scrubber in a natural gas purification plant","authors":"Ganghua Huang ,&nbsp;Jingjing Jiang ,&nbsp;Rui Fan ,&nbsp;Chao Miao ,&nbsp;Yongfan Tang ,&nbsp;Shuang Yang","doi":"10.1016/j.jlp.2024.105374","DOIUrl":null,"url":null,"abstract":"<div><p>The flue gases such as SO<sub>2</sub>, SO<sub>3</sub>, and CO<sub>2</sub> generated during the purification process of sulfur-containing natural gas need to be treated to a certain concentration before they can be discharged into the atmosphere. The flue gas unit of a purification plant in Sichuan adopts the new Cansolv flue gas treatment process. After running for a period of time, the Venturi scrubber experienced severe corrosion failure, resulting in equipment shutdown and significant economic losses. This paper utilizes an actual failed device as a case study to analyze the corrosion environment of the Venturi scrubber. It conducts a comprehensive failure analysis, encompassing material mechanical properties, metallographic analysis, and failure microstructure analysis, aiming to elucidate the reasons behind the Venturi scrubber failure. Systematic analysis shows that the manufacturing materials used in this scrubber meet all design requirements. However, flue gas at temperatures reaching 280 °C enters the scrubber tower at a flow rate exceeding 10 m/s. The dissolution of acidic gases leads to a significant drop in the pH of the cooling water to 1, manifesting evident signs of erosion corrosion and intergranular corrosion on the material surface. These observations suggest that erosion and intergranular corrosion in high-temperature acidic environments are the predominant factors contributing to the corrosion failure of the Venturi scrubber.</p></div>","PeriodicalId":16291,"journal":{"name":"Journal of Loss Prevention in The Process Industries","volume":null,"pages":null},"PeriodicalIF":3.6000,"publicationDate":"2024-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Loss Prevention in The Process Industries","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0950423024001323","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The flue gases such as SO2, SO3, and CO2 generated during the purification process of sulfur-containing natural gas need to be treated to a certain concentration before they can be discharged into the atmosphere. The flue gas unit of a purification plant in Sichuan adopts the new Cansolv flue gas treatment process. After running for a period of time, the Venturi scrubber experienced severe corrosion failure, resulting in equipment shutdown and significant economic losses. This paper utilizes an actual failed device as a case study to analyze the corrosion environment of the Venturi scrubber. It conducts a comprehensive failure analysis, encompassing material mechanical properties, metallographic analysis, and failure microstructure analysis, aiming to elucidate the reasons behind the Venturi scrubber failure. Systematic analysis shows that the manufacturing materials used in this scrubber meet all design requirements. However, flue gas at temperatures reaching 280 °C enters the scrubber tower at a flow rate exceeding 10 m/s. The dissolution of acidic gases leads to a significant drop in the pH of the cooling water to 1, manifesting evident signs of erosion corrosion and intergranular corrosion on the material surface. These observations suggest that erosion and intergranular corrosion in high-temperature acidic environments are the predominant factors contributing to the corrosion failure of the Venturi scrubber.

S31254 不锈钢的腐蚀和晶间腐蚀诱发故障 - 天然气净化厂文丘里洗涤器案例研究
含硫天然气在净化过程中产生的 SO2、SO3 和 CO2 等烟气需要处理到一定浓度后才能排放到大气中。四川某净化厂的烟气装置采用了新型 Cansolv 烟气处理工艺。运行一段时间后,文丘里洗涤器出现严重腐蚀故障,导致设备停运,造成重大经济损失。本文以实际故障设备为案例,分析了文丘里洗涤器的腐蚀环境。本文进行了全面的失效分析,包括材料机械性能、金相分析和失效微观结构分析,旨在阐明文丘里洗涤器失效的原因。系统分析显示,该洗涤器使用的制造材料符合所有设计要求。然而,温度高达 280 °C 的烟气以超过 10 m/s 的流速进入洗涤塔。酸性气体的溶解导致冷却水的 pH 值显著降至 1,材料表面出现明显的侵蚀腐蚀和晶间腐蚀迹象。这些观察结果表明,高温酸性环境中的侵蚀和晶间腐蚀是导致文丘里洗涤器腐蚀失效的主要因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.20
自引率
14.30%
发文量
226
审稿时长
52 days
期刊介绍: The broad scope of the journal is process safety. Process safety is defined as the prevention and mitigation of process-related injuries and damage arising from process incidents involving fire, explosion and toxic release. Such undesired events occur in the process industries during the use, storage, manufacture, handling, and transportation of highly hazardous chemicals.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信