Effect of Aligning Forces by Two Preadjusted Edgewise Techniques on a Buccally Positioned Maxillary Canine at Varying Vertical Displacements: A Finite Element Study.

IF 0.8 Q4 DENTISTRY, ORAL SURGERY & MEDICINE
Steve Mathew, Puneet Batra, Nitin Arora, Ashish Kumar Singh, Sridhar Kannan, Aditya Talwar
{"title":"Effect of Aligning Forces by Two Preadjusted Edgewise Techniques on a Buccally Positioned Maxillary Canine at Varying Vertical Displacements: A Finite Element Study.","authors":"Steve Mathew, Puneet Batra, Nitin Arora, Ashish Kumar Singh, Sridhar Kannan, Aditya Talwar","doi":"10.4274/TurkJOrthod.2023.2022.172","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the effect of continuous arch and piggyback mechanics in a straight wire appliance (SWA) for the alignment of buccal and variably vertically positioned maxillary canines.</p><p><strong>Methods: </strong>A three-dimensional finite element model with near-normal occlusion and buccal and vertically displaced maxillary canines was used. Two groups were created to simulate two commonly used SWAs techniques, continuous archwire (Group 1) and piggyback models (Group 2). Each group had three subgroups with varying vertical displacement of the canine from 2 to 6 mm from the occlusal plane. The displacement and stress distribution were noted in each group.</p><p><strong>Results: </strong>As the vertical displacement increased in Group 1, the concentration of von Mises stress increased progressively at the incisal third (0.36, 0.41 and 0.44 MPa) at 2, 4, and 6 mm, respectively, with decreased maximum occlusal movement in the vertical plane with respect to the canine. Group 2 exhibited a similar pattern but greater occlusal movement of the canine compared with Group 1.</p><p><strong>Conclusion: </strong>A vertical displacement of 4 mm is the optimal level at which continuous arch mechanics should be considered. For displacements beyond 4 mm, the piggyback wire technique is a suitable alternative.</p>","PeriodicalId":37013,"journal":{"name":"Turkish Journal of Orthodontics","volume":"37 2","pages":"122-129"},"PeriodicalIF":0.8000,"publicationDate":"2024-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11589248/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Orthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4274/TurkJOrthod.2023.2022.172","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To evaluate the effect of continuous arch and piggyback mechanics in a straight wire appliance (SWA) for the alignment of buccal and variably vertically positioned maxillary canines.

Methods: A three-dimensional finite element model with near-normal occlusion and buccal and vertically displaced maxillary canines was used. Two groups were created to simulate two commonly used SWAs techniques, continuous archwire (Group 1) and piggyback models (Group 2). Each group had three subgroups with varying vertical displacement of the canine from 2 to 6 mm from the occlusal plane. The displacement and stress distribution were noted in each group.

Results: As the vertical displacement increased in Group 1, the concentration of von Mises stress increased progressively at the incisal third (0.36, 0.41 and 0.44 MPa) at 2, 4, and 6 mm, respectively, with decreased maximum occlusal movement in the vertical plane with respect to the canine. Group 2 exhibited a similar pattern but greater occlusal movement of the canine compared with Group 1.

Conclusion: A vertical displacement of 4 mm is the optimal level at which continuous arch mechanics should be considered. For displacements beyond 4 mm, the piggyback wire technique is a suitable alternative.

两种预调边缘技术在不同垂直位移下对颊侧定位上颌犬齿的对齐力影响:有限元研究。
目的评估直丝矫治器(SWA)中的连续牙弓和捎带机制对上颌颊侧和不同垂直位置的犬齿排列的影响:方法: 使用一个三维有限元模型,该模型的咬合情况接近正常,上颌犬齿有颊侧和垂直位移。模型分为两组,分别模拟两种常用的SWAs技术:连续弓丝(第1组)和捎带模型(第2组)。每组有三个子组,上颌犬齿的垂直位移从咬合平面的 2 毫米到 6 毫米不等。结果:结果:随着第 1 组垂直位移的增加,在 2、4 和 6 mm 时,切缘三分之一处的 von Mises 应力浓度逐渐增加(分别为 0.36、0.41 和 0.44 MPa),相对于犬齿,垂直面上的最大咬合移动量减少。与第一组相比,第二组表现出类似的模式,但犬齿的咬合移动更大:结论:4 毫米的垂直位移是考虑连续牙弓力学的最佳水平。结论:4 毫米的垂直位移是考虑连续牙弓力学的最佳水平,对于超过 4 毫米的位移,背负式钢丝技术是一个合适的替代方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Turkish Journal of Orthodontics
Turkish Journal of Orthodontics Dentistry-Orthodontics
CiteScore
2.10
自引率
9.10%
发文量
34
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信