Julia E Todderud, Todd A Milbrandt, Edward Floyd, Geoffrey Haft, Ron El-Hawary, Michael Albert, A Noelle Larson
{"title":"Preliminary Study of Motion Preservation Following Posterior Dynamic Distraction Device in Adolescent Idiopathic Scoliosis Patients.","authors":"Julia E Todderud, Todd A Milbrandt, Edward Floyd, Geoffrey Haft, Ron El-Hawary, Michael Albert, A Noelle Larson","doi":"10.1097/BPO.0000000000002739","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Motion-sparing scoliosis surgeries such as the posterior dynamic distraction device (PDDD) are slowly increasing in use. However, there is limited clinical data documenting postoperative motion across the PDDD construct. With this cohort study, we aim to measure sagittal and coronal motion following PDDD. We hypothesize coronal and sagittal spinal motion will be partially preserved across the construct.</p><p><strong>Methods: </strong>Retrospective review of prospectively collected data. Preoperative and minimum 1-year postoperative coronal range of motion across the instrumented levels was compared. Available flexion/extension radiographs were evaluated postoperatively to assess sagittal arc of motion. Radiographs from latest follow-up were used.</p><p><strong>Results: </strong>At a mean of 1.9 years (1 to 5 y), flexibility radiographs were available on 29 patients treated with PDDD (17 thoracic, 12 lumbar). Mean age at surgery was 16 years (12 to 25). Postoperative coronal arc of motion in PDDD patients was 11 degrees (3 to 19 degrees) in the thoracic spine and 10 degrees (0 to 28 degrees) in the lumbar spine. Compared with preoperative motion, the thoracic arc of motion was maintained by 33% (35 to 11 degrees) and lumbar motion was maintained by 30% (34 to 10 degrees). Flexion-extension radiographs were available on 7 patients. Sagittal arc for the upper instrumented vertebral end plate to the lower instrumented vertebral endplate of the cohort was 10 degrees in the thoracic spine (6 to 18) and 14 degrees in the lumbar spine (5 to 21). Sagittal measurements for the changes in the arc of the upper and lower screws on the construct were 4 degrees in the thoracic group (2 to 8) and 9 degrees in the lumbar group (2 to 17). By latest follow-up 11 patients (38%) underwent reoperation, with most cases due to implant breakage (N=4, 14%), extender misalignment (N=2, 7%), and screw misplacement (N=2, 7%).</p><p><strong>Conclusion: </strong>At mean 1.9 years postoperatively, PDDD preserves measurable spinal motion over the construct both in the coronal and the sagittal plane without evidence for autofusion. Coronal arc of motion averages 10 to 12 degrees and sagittal arc of motion ranged from 4 to 14 degrees, although this varies by patient. This study confirms that PDDD for pediatric scoliosis preserves a measurable degree of postoperative flexibility both in the sagittal and coronal planes.</p><p><strong>Level of evidence: </strong>Level II-therapeutic study.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/BPO.0000000000002739","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/1 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Motion-sparing scoliosis surgeries such as the posterior dynamic distraction device (PDDD) are slowly increasing in use. However, there is limited clinical data documenting postoperative motion across the PDDD construct. With this cohort study, we aim to measure sagittal and coronal motion following PDDD. We hypothesize coronal and sagittal spinal motion will be partially preserved across the construct.
Methods: Retrospective review of prospectively collected data. Preoperative and minimum 1-year postoperative coronal range of motion across the instrumented levels was compared. Available flexion/extension radiographs were evaluated postoperatively to assess sagittal arc of motion. Radiographs from latest follow-up were used.
Results: At a mean of 1.9 years (1 to 5 y), flexibility radiographs were available on 29 patients treated with PDDD (17 thoracic, 12 lumbar). Mean age at surgery was 16 years (12 to 25). Postoperative coronal arc of motion in PDDD patients was 11 degrees (3 to 19 degrees) in the thoracic spine and 10 degrees (0 to 28 degrees) in the lumbar spine. Compared with preoperative motion, the thoracic arc of motion was maintained by 33% (35 to 11 degrees) and lumbar motion was maintained by 30% (34 to 10 degrees). Flexion-extension radiographs were available on 7 patients. Sagittal arc for the upper instrumented vertebral end plate to the lower instrumented vertebral endplate of the cohort was 10 degrees in the thoracic spine (6 to 18) and 14 degrees in the lumbar spine (5 to 21). Sagittal measurements for the changes in the arc of the upper and lower screws on the construct were 4 degrees in the thoracic group (2 to 8) and 9 degrees in the lumbar group (2 to 17). By latest follow-up 11 patients (38%) underwent reoperation, with most cases due to implant breakage (N=4, 14%), extender misalignment (N=2, 7%), and screw misplacement (N=2, 7%).
Conclusion: At mean 1.9 years postoperatively, PDDD preserves measurable spinal motion over the construct both in the coronal and the sagittal plane without evidence for autofusion. Coronal arc of motion averages 10 to 12 degrees and sagittal arc of motion ranged from 4 to 14 degrees, although this varies by patient. This study confirms that PDDD for pediatric scoliosis preserves a measurable degree of postoperative flexibility both in the sagittal and coronal planes.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.