Effectiveness of ceiling-mounted ultraviolet-C lamps: An experimental study in a biocontainment unit of a tertiary care hospital.

IF 3.8 3区 医学 Q2 INFECTIOUS DISEASES
Jeongyoung Lee, Eun Ju Kim, Young-Ju Lim, Eun Ok Kim, Seongman Bae, Jiwon Jung, Sung-Han Kim
{"title":"Effectiveness of ceiling-mounted ultraviolet-C lamps: An experimental study in a biocontainment unit of a tertiary care hospital.","authors":"Jeongyoung Lee, Eun Ju Kim, Young-Ju Lim, Eun Ok Kim, Seongman Bae, Jiwon Jung, Sung-Han Kim","doi":"10.1016/j.ajic.2024.06.020","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>We aimed to evaluate the performance of ceiling-mounted UV-C lamps.</p><p><strong>Methods: </strong>This study was conducted in an empty room with UV-C lamps in the biocontainment unit of a tertiary care hospital in South Korea. Each pathogen (Staphylococcus aureus, Escherichia coli, Candida krusei, Bacillus cereus, and Mycobacterium peregrinum) was inoculated on blood agar plates and placed in 20 selected places from the UV-C lamp, and irradiation was applied for 15 min. As a control group, the bacterial solution was diluted 10,000 times and UV was not applied.</p><p><strong>Results: </strong>A mean ± SD of 5.95 ± 0.91 log reduction was observed with UV irradiation compared with the control. The log reduction was greatest for S. aureus [median, 7.05 (IQR, 6.49-7.26)] and least for M. peregrinum [median, 4.88 (IQR, 4.58-5.24)]. The degree of log reduction was inversely proportional to the square of the distance from the UV-C lamp (R<sup>2</sup> = -0.12, P < .001).</p><p><strong>Conclusions: </strong>In this study, ceiling-mounted UV-C demonstrated effective disinfection of at least 4-log reduction of the test organisms within a 4-m distance. Mounted UV-C lighting is a considerable option for improving surface disinfection.</p>","PeriodicalId":7621,"journal":{"name":"American journal of infection control","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of infection control","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.ajic.2024.06.020","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0

Abstract

Background: We aimed to evaluate the performance of ceiling-mounted UV-C lamps.

Methods: This study was conducted in an empty room with UV-C lamps in the biocontainment unit of a tertiary care hospital in South Korea. Each pathogen (Staphylococcus aureus, Escherichia coli, Candida krusei, Bacillus cereus, and Mycobacterium peregrinum) was inoculated on blood agar plates and placed in 20 selected places from the UV-C lamp, and irradiation was applied for 15 min. As a control group, the bacterial solution was diluted 10,000 times and UV was not applied.

Results: A mean ± SD of 5.95 ± 0.91 log reduction was observed with UV irradiation compared with the control. The log reduction was greatest for S. aureus [median, 7.05 (IQR, 6.49-7.26)] and least for M. peregrinum [median, 4.88 (IQR, 4.58-5.24)]. The degree of log reduction was inversely proportional to the square of the distance from the UV-C lamp (R2 = -0.12, P < .001).

Conclusions: In this study, ceiling-mounted UV-C demonstrated effective disinfection of at least 4-log reduction of the test organisms within a 4-m distance. Mounted UV-C lighting is a considerable option for improving surface disinfection.

安装在天花板上的紫外线-C 灯的效果:在一家三甲医院生物隔离病房进行的实验研究。
背景:安装在天花板上的紫外线-C灯管不需要单独的空间或人力运输,但有关其表面消毒效果的数据却很少。我们的目的是评估安装在天花板上的紫外线-C 灯的性能:这项研究是在韩国一家三甲医院生物隔离病房的一个装有紫外线-C 灯的空房间里进行的。紫外线-C 灯安装在病房、前厅和厕所的天花板上。将每种病原体(金黄色葡萄球菌、大肠杆菌、克柔斯念珠菌、蜡样芽孢杆菌和佩氏分枝杆菌)接种到血琼脂平板上,并放置在距离紫外线-C 灯 20 个选定位置,照射 15 分钟。作为对照组,菌液稀释 10 000 倍,不照射紫外线:与对照组相比,紫外线照射平均(±SD)减少了 5.95 ± 0.91 个对数。金黄色葡萄球菌的对数降低幅度最大[中位数,7.05(IQR,6.49-7.26)],佩里格氏菌的对数降低幅度最小[中位数,4.88(IQR,4.58-5.24)]。对数减少的程度与紫外线-C 灯距离的平方成反比(R2 = -0.12,p < 0.001):在这项研究中,安装在天花板上的紫外线-C 能在 4 米距离内有效消毒,至少能将测试微生物的对数减少 4 个对数。安装紫外线-C 照明设备是提高表面消毒效果的重要选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.40
自引率
4.10%
发文量
479
审稿时长
24 days
期刊介绍: AJIC covers key topics and issues in infection control and epidemiology. Infection control professionals, including physicians, nurses, and epidemiologists, rely on AJIC for peer-reviewed articles covering clinical topics as well as original research. As the official publication of the Association for Professionals in Infection Control and Epidemiology (APIC)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信